Graduation technique for vibration flow device for grain mass moisture control

The article shows that sampling of grain while controlling the moisture content is carried out in accordance with the current recommendations and standards. The mass of a sample should be sufficient to form 10-15 samples with uniformly distributed moisture values with an interval of no more than 3-4...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ivashina Alexander, Adoshev Andrey, Antonov Sergey, Zhdanov Valery
Formato: article
Lenguaje:EN
FR
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/a48782efa55f49a08f69cb70cfa98687
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:a48782efa55f49a08f69cb70cfa98687
record_format dspace
spelling oai:doaj.org-article:a48782efa55f49a08f69cb70cfa986872021-11-08T15:17:30ZGraduation technique for vibration flow device for grain mass moisture control2117-445810.1051/bioconf/20213700099https://doaj.org/article/a48782efa55f49a08f69cb70cfa986872021-01-01T00:00:00Zhttps://www.bio-conferences.org/articles/bioconf/pdf/2021/09/bioconf_fies2021_00099.pdfhttps://doaj.org/toc/2117-4458The article shows that sampling of grain while controlling the moisture content is carried out in accordance with the current recommendations and standards. The mass of a sample should be sufficient to form 10-15 samples with uniformly distributed moisture values with an interval of no more than 3-4% in the measurement range of a vibration-flow moisture meter. Determination of grain moisture is carried out by the thermogravimetric method using a drying oven as a standard in the following sequence. Measurements with a moisture meter are taken at least three times. For the final measurement result, the average value α of the moisture meter readings from a series of successive measurements is taken. The range in a series of measurements should not exceed 0.05α; otherwise the measurements are repeated. The moisture measurement results and the corresponding readings of the device are entered in the appropriate table. When constructing graduation curves, a correlation-regression analysis of the measurement results is carried out, which is as follows. A correlation field is constructed - a graphical representation of the relationship between the moisture values of the material Wi and the readings of the moisture meter αi. If the analysis is performed correctly, the theoretical regression line plotted on the correlation field should be located as close as possible to the experimental measurement points. The basic error of the vibration-flow moisture meter, obtained as a result of the calculation, should not exceed the permissible value. Otherwise, the graduation of the moisture meter is repeated.Ivashina AlexanderAdoshev AndreyAntonov SergeyZhdanov ValeryEDP SciencesarticleMicrobiologyQR1-502PhysiologyQP1-981ZoologyQL1-991ENFRBIO Web of Conferences, Vol 37, p 00099 (2021)
institution DOAJ
collection DOAJ
language EN
FR
topic Microbiology
QR1-502
Physiology
QP1-981
Zoology
QL1-991
spellingShingle Microbiology
QR1-502
Physiology
QP1-981
Zoology
QL1-991
Ivashina Alexander
Adoshev Andrey
Antonov Sergey
Zhdanov Valery
Graduation technique for vibration flow device for grain mass moisture control
description The article shows that sampling of grain while controlling the moisture content is carried out in accordance with the current recommendations and standards. The mass of a sample should be sufficient to form 10-15 samples with uniformly distributed moisture values with an interval of no more than 3-4% in the measurement range of a vibration-flow moisture meter. Determination of grain moisture is carried out by the thermogravimetric method using a drying oven as a standard in the following sequence. Measurements with a moisture meter are taken at least three times. For the final measurement result, the average value α of the moisture meter readings from a series of successive measurements is taken. The range in a series of measurements should not exceed 0.05α; otherwise the measurements are repeated. The moisture measurement results and the corresponding readings of the device are entered in the appropriate table. When constructing graduation curves, a correlation-regression analysis of the measurement results is carried out, which is as follows. A correlation field is constructed - a graphical representation of the relationship between the moisture values of the material Wi and the readings of the moisture meter αi. If the analysis is performed correctly, the theoretical regression line plotted on the correlation field should be located as close as possible to the experimental measurement points. The basic error of the vibration-flow moisture meter, obtained as a result of the calculation, should not exceed the permissible value. Otherwise, the graduation of the moisture meter is repeated.
format article
author Ivashina Alexander
Adoshev Andrey
Antonov Sergey
Zhdanov Valery
author_facet Ivashina Alexander
Adoshev Andrey
Antonov Sergey
Zhdanov Valery
author_sort Ivashina Alexander
title Graduation technique for vibration flow device for grain mass moisture control
title_short Graduation technique for vibration flow device for grain mass moisture control
title_full Graduation technique for vibration flow device for grain mass moisture control
title_fullStr Graduation technique for vibration flow device for grain mass moisture control
title_full_unstemmed Graduation technique for vibration flow device for grain mass moisture control
title_sort graduation technique for vibration flow device for grain mass moisture control
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/a48782efa55f49a08f69cb70cfa98687
work_keys_str_mv AT ivashinaalexander graduationtechniqueforvibrationflowdeviceforgrainmassmoisturecontrol
AT adoshevandrey graduationtechniqueforvibrationflowdeviceforgrainmassmoisturecontrol
AT antonovsergey graduationtechniqueforvibrationflowdeviceforgrainmassmoisturecontrol
AT zhdanovvalery graduationtechniqueforvibrationflowdeviceforgrainmassmoisturecontrol
_version_ 1718442074620035072