Graduation technique for vibration flow device for grain mass moisture control
The article shows that sampling of grain while controlling the moisture content is carried out in accordance with the current recommendations and standards. The mass of a sample should be sufficient to form 10-15 samples with uniformly distributed moisture values with an interval of no more than 3-4...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN FR |
Publicado: |
EDP Sciences
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/a48782efa55f49a08f69cb70cfa98687 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:a48782efa55f49a08f69cb70cfa98687 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a48782efa55f49a08f69cb70cfa986872021-11-08T15:17:30ZGraduation technique for vibration flow device for grain mass moisture control2117-445810.1051/bioconf/20213700099https://doaj.org/article/a48782efa55f49a08f69cb70cfa986872021-01-01T00:00:00Zhttps://www.bio-conferences.org/articles/bioconf/pdf/2021/09/bioconf_fies2021_00099.pdfhttps://doaj.org/toc/2117-4458The article shows that sampling of grain while controlling the moisture content is carried out in accordance with the current recommendations and standards. The mass of a sample should be sufficient to form 10-15 samples with uniformly distributed moisture values with an interval of no more than 3-4% in the measurement range of a vibration-flow moisture meter. Determination of grain moisture is carried out by the thermogravimetric method using a drying oven as a standard in the following sequence. Measurements with a moisture meter are taken at least three times. For the final measurement result, the average value α of the moisture meter readings from a series of successive measurements is taken. The range in a series of measurements should not exceed 0.05α; otherwise the measurements are repeated. The moisture measurement results and the corresponding readings of the device are entered in the appropriate table. When constructing graduation curves, a correlation-regression analysis of the measurement results is carried out, which is as follows. A correlation field is constructed - a graphical representation of the relationship between the moisture values of the material Wi and the readings of the moisture meter αi. If the analysis is performed correctly, the theoretical regression line plotted on the correlation field should be located as close as possible to the experimental measurement points. The basic error of the vibration-flow moisture meter, obtained as a result of the calculation, should not exceed the permissible value. Otherwise, the graduation of the moisture meter is repeated.Ivashina AlexanderAdoshev AndreyAntonov SergeyZhdanov ValeryEDP SciencesarticleMicrobiologyQR1-502PhysiologyQP1-981ZoologyQL1-991ENFRBIO Web of Conferences, Vol 37, p 00099 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN FR |
topic |
Microbiology QR1-502 Physiology QP1-981 Zoology QL1-991 |
spellingShingle |
Microbiology QR1-502 Physiology QP1-981 Zoology QL1-991 Ivashina Alexander Adoshev Andrey Antonov Sergey Zhdanov Valery Graduation technique for vibration flow device for grain mass moisture control |
description |
The article shows that sampling of grain while controlling the moisture content is carried out in accordance with the current recommendations and standards. The mass of a sample should be sufficient to form 10-15 samples with uniformly distributed moisture values with an interval of no more than 3-4% in the measurement range of a vibration-flow moisture meter. Determination of grain moisture is carried out by the thermogravimetric method using a drying oven as a standard in the following sequence. Measurements with a moisture meter are taken at least three times. For the final measurement result, the average value α of the moisture meter readings from a series of successive measurements is taken. The range in a series of measurements should not exceed 0.05α; otherwise the measurements are repeated. The moisture measurement results and the corresponding readings of the device are entered in the appropriate table. When constructing graduation curves, a correlation-regression analysis of the measurement results is carried out, which is as follows. A correlation field is constructed - a graphical representation of the relationship between the moisture values of the material Wi and the readings of the moisture meter αi. If the analysis is performed correctly, the theoretical regression line plotted on the correlation field should be located as close as possible to the experimental measurement points. The basic error of the vibration-flow moisture meter, obtained as a result of the calculation, should not exceed the permissible value. Otherwise, the graduation of the moisture meter is repeated. |
format |
article |
author |
Ivashina Alexander Adoshev Andrey Antonov Sergey Zhdanov Valery |
author_facet |
Ivashina Alexander Adoshev Andrey Antonov Sergey Zhdanov Valery |
author_sort |
Ivashina Alexander |
title |
Graduation technique for vibration flow device for grain mass moisture control |
title_short |
Graduation technique for vibration flow device for grain mass moisture control |
title_full |
Graduation technique for vibration flow device for grain mass moisture control |
title_fullStr |
Graduation technique for vibration flow device for grain mass moisture control |
title_full_unstemmed |
Graduation technique for vibration flow device for grain mass moisture control |
title_sort |
graduation technique for vibration flow device for grain mass moisture control |
publisher |
EDP Sciences |
publishDate |
2021 |
url |
https://doaj.org/article/a48782efa55f49a08f69cb70cfa98687 |
work_keys_str_mv |
AT ivashinaalexander graduationtechniqueforvibrationflowdeviceforgrainmassmoisturecontrol AT adoshevandrey graduationtechniqueforvibrationflowdeviceforgrainmassmoisturecontrol AT antonovsergey graduationtechniqueforvibrationflowdeviceforgrainmassmoisturecontrol AT zhdanovvalery graduationtechniqueforvibrationflowdeviceforgrainmassmoisturecontrol |
_version_ |
1718442074620035072 |