Influence of frosted haptics on rotational stability of toric intraocular lenses

Abstract We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson & Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ruriko Takaku, Shinichiro Nakano, Masaharu Iida, Tetsuro Oshika
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/a55127cab60b4766be958ea23b8d81b7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:a55127cab60b4766be958ea23b8d81b7
record_format dspace
spelling oai:doaj.org-article:a55127cab60b4766be958ea23b8d81b72021-12-02T16:50:24ZInfluence of frosted haptics on rotational stability of toric intraocular lenses10.1038/s41598-021-94293-32045-2322https://doaj.org/article/a55127cab60b4766be958ea23b8d81b72021-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-94293-3https://doaj.org/toc/2045-2322Abstract We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson & Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics with toric-II IOL. The study consisted of two parts; experimental study and clinical, retrospective, case series. Experimental study indicated that the overall time from IOL ejection to unfolding to 11 mm was significantly shorter with toricII than toric-I IOLs (p = 0.032), due to the earlier separation of the haptics from the optic with toric-II IOL. Clinical study included 131 eyes of 99 patients who had undergone phacoemulsification and toric IOL implantation. At 3 months postoperatively, toric-II IOL showed significantly better rotational stability than toric-I IOL, including smaller residual manifest astigmatism (p = 0.018), less amount of axis misalignment from the intended axis (p = 0.04), lower incidence of misalignment > 10º (p = 0.0044), and less degree of prediction errors (p = 0.043). Postoperative uncorrected distance visual acuity tended to be better in the toric-II than in the toric-I groups, with marginal statistical difference (p = 0.057). TECNIS toric II IOL with the frosted haptics showed significantly better rotational stability than its predecessor, probably due to quicker unfolding and greater friction with the capsular bag.Ruriko TakakuShinichiro NakanoMasaharu IidaTetsuro OshikaNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-7 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Ruriko Takaku
Shinichiro Nakano
Masaharu Iida
Tetsuro Oshika
Influence of frosted haptics on rotational stability of toric intraocular lenses
description Abstract We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson & Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics with toric-II IOL. The study consisted of two parts; experimental study and clinical, retrospective, case series. Experimental study indicated that the overall time from IOL ejection to unfolding to 11 mm was significantly shorter with toricII than toric-I IOLs (p = 0.032), due to the earlier separation of the haptics from the optic with toric-II IOL. Clinical study included 131 eyes of 99 patients who had undergone phacoemulsification and toric IOL implantation. At 3 months postoperatively, toric-II IOL showed significantly better rotational stability than toric-I IOL, including smaller residual manifest astigmatism (p = 0.018), less amount of axis misalignment from the intended axis (p = 0.04), lower incidence of misalignment > 10º (p = 0.0044), and less degree of prediction errors (p = 0.043). Postoperative uncorrected distance visual acuity tended to be better in the toric-II than in the toric-I groups, with marginal statistical difference (p = 0.057). TECNIS toric II IOL with the frosted haptics showed significantly better rotational stability than its predecessor, probably due to quicker unfolding and greater friction with the capsular bag.
format article
author Ruriko Takaku
Shinichiro Nakano
Masaharu Iida
Tetsuro Oshika
author_facet Ruriko Takaku
Shinichiro Nakano
Masaharu Iida
Tetsuro Oshika
author_sort Ruriko Takaku
title Influence of frosted haptics on rotational stability of toric intraocular lenses
title_short Influence of frosted haptics on rotational stability of toric intraocular lenses
title_full Influence of frosted haptics on rotational stability of toric intraocular lenses
title_fullStr Influence of frosted haptics on rotational stability of toric intraocular lenses
title_full_unstemmed Influence of frosted haptics on rotational stability of toric intraocular lenses
title_sort influence of frosted haptics on rotational stability of toric intraocular lenses
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/a55127cab60b4766be958ea23b8d81b7
work_keys_str_mv AT rurikotakaku influenceoffrostedhapticsonrotationalstabilityoftoricintraocularlenses
AT shinichironakano influenceoffrostedhapticsonrotationalstabilityoftoricintraocularlenses
AT masaharuiida influenceoffrostedhapticsonrotationalstabilityoftoricintraocularlenses
AT tetsurooshika influenceoffrostedhapticsonrotationalstabilityoftoricintraocularlenses
_version_ 1718383055607955456