Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.

<h4>Purpose</h4>To compare the biometry and prediction of postoperative refractive outcomes of four different formulae (Haigis, SRK/T, Holladay1, Barrett Universal II) obtained by swept-source optical coherence tomography (SS-OCT) biometers and partial coherence interferometry (PCI; IOLM...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mi Yeon Song, Sung Rae Noh, Kook Young Kim
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/a5c2b2f36f764388ad154d7af48bc7e9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:a5c2b2f36f764388ad154d7af48bc7e9
record_format dspace
spelling oai:doaj.org-article:a5c2b2f36f764388ad154d7af48bc7e92021-11-25T06:19:20ZRefractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.1932-620310.1371/journal.pone.0251152https://doaj.org/article/a5c2b2f36f764388ad154d7af48bc7e92021-01-01T00:00:00Zhttps://doi.org/10.1371/journal.pone.0251152https://doaj.org/toc/1932-6203<h4>Purpose</h4>To compare the biometry and prediction of postoperative refractive outcomes of four different formulae (Haigis, SRK/T, Holladay1, Barrett Universal II) obtained by swept-source optical coherence tomography (SS-OCT) biometers and partial coherence interferometry (PCI; IOLMaster ver 5.4).<h4>Methods</h4>We compared the biometric values of SS-OCT (ANTERION, Heidelberg Engineering Inc., Heidelberg, Germany) and PCI (IOLMaster, Carl Zeiss Meditec, Jena, Germany). Predictive errors calculated using four different formulae (Haigis, SRKT, Holladay1, Barrett Universal II) were compared at 1 month after cataract surgery.<h4>Results</h4>The mean preoperative axial length (AL) showed no statistically significant difference between SS-OCT and PCI (SS-OCT: 23.78 ± 0.12 mm and PCI: 23.77 ± 0.12 mm). The mean anterior chamber depth (ACD) was 3.30 ± 0.04 mm for SS-OCT and 3.23 ± 0.04 mm for PCI, which was significantly different between the two techniques. The mean corneal curvature also differed significantly between the two techniques. The difference in mean arithmetic prediction error was significant in the Haigis, SRKT, and Holladay1 formulae. The difference in mean absolute prediction error was significant in all four formulae.<h4>Conclusions</h4>SS-OCT and PCI demonstrated good agreement on biometric measurements; however, there were significant differences in some biometric values. These differences in some ocular biometrics can cause a difference in refractive error after cataract surgery. New type SS-OCT was not superior to the IOL power prediction calculated by PCI.Mi Yeon SongSung Rae NohKook Young KimPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 16, Iss 5, p e0251152 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Mi Yeon Song
Sung Rae Noh
Kook Young Kim
Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.
description <h4>Purpose</h4>To compare the biometry and prediction of postoperative refractive outcomes of four different formulae (Haigis, SRK/T, Holladay1, Barrett Universal II) obtained by swept-source optical coherence tomography (SS-OCT) biometers and partial coherence interferometry (PCI; IOLMaster ver 5.4).<h4>Methods</h4>We compared the biometric values of SS-OCT (ANTERION, Heidelberg Engineering Inc., Heidelberg, Germany) and PCI (IOLMaster, Carl Zeiss Meditec, Jena, Germany). Predictive errors calculated using four different formulae (Haigis, SRKT, Holladay1, Barrett Universal II) were compared at 1 month after cataract surgery.<h4>Results</h4>The mean preoperative axial length (AL) showed no statistically significant difference between SS-OCT and PCI (SS-OCT: 23.78 ± 0.12 mm and PCI: 23.77 ± 0.12 mm). The mean anterior chamber depth (ACD) was 3.30 ± 0.04 mm for SS-OCT and 3.23 ± 0.04 mm for PCI, which was significantly different between the two techniques. The mean corneal curvature also differed significantly between the two techniques. The difference in mean arithmetic prediction error was significant in the Haigis, SRKT, and Holladay1 formulae. The difference in mean absolute prediction error was significant in all four formulae.<h4>Conclusions</h4>SS-OCT and PCI demonstrated good agreement on biometric measurements; however, there were significant differences in some biometric values. These differences in some ocular biometrics can cause a difference in refractive error after cataract surgery. New type SS-OCT was not superior to the IOL power prediction calculated by PCI.
format article
author Mi Yeon Song
Sung Rae Noh
Kook Young Kim
author_facet Mi Yeon Song
Sung Rae Noh
Kook Young Kim
author_sort Mi Yeon Song
title Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.
title_short Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.
title_full Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.
title_fullStr Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.
title_full_unstemmed Refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.
title_sort refractive prediction of four different intraocular lens calculation formulas compared between new swept source optical coherence tomography and partial coherence interferometry.
publisher Public Library of Science (PLoS)
publishDate 2021
url https://doaj.org/article/a5c2b2f36f764388ad154d7af48bc7e9
work_keys_str_mv AT miyeonsong refractivepredictionoffourdifferentintraocularlenscalculationformulascomparedbetweennewsweptsourceopticalcoherencetomographyandpartialcoherenceinterferometry
AT sungraenoh refractivepredictionoffourdifferentintraocularlenscalculationformulascomparedbetweennewsweptsourceopticalcoherencetomographyandpartialcoherenceinterferometry
AT kookyoungkim refractivepredictionoffourdifferentintraocularlenscalculationformulascomparedbetweennewsweptsourceopticalcoherencetomographyandpartialcoherenceinterferometry
_version_ 1718413883512717312