Utility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy
Shinji MakinoDepartment of Ophthalmology, Jichi Medical University, Shimotsuke, Tochigi, JapanAbstract: A 68-year-old woman with bilateral idiopathic optic neuropathy was examined using blue-on-yellow perimetry. Best-corrected visual acuity was 0.5 and 0.6 in her right and left eyes, respectively. V...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/a6aa3015d25f43be89ee5513cae0d5db |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:a6aa3015d25f43be89ee5513cae0d5db |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a6aa3015d25f43be89ee5513cae0d5db2021-12-02T04:44:21ZUtility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy1177-54671177-5483https://doaj.org/article/a6aa3015d25f43be89ee5513cae0d5db2013-06-01T00:00:00Zhttp://www.dovepress.com/utility-of-blue-on-yellow-perimetry-in-the-evaluation-of-patients-with-a13507https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Shinji MakinoDepartment of Ophthalmology, Jichi Medical University, Shimotsuke, Tochigi, JapanAbstract: A 68-year-old woman with bilateral idiopathic optic neuropathy was examined using blue-on-yellow perimetry. Best-corrected visual acuity was 0.5 and 0.6 in her right and left eyes, respectively. Visual field testing with a Goldmann perimeter showed constriction of the I/2 e isopter in both eyes. With regard to mean deviation, the results (–13.18 dB right, –10.01 dB left) of blue-on-yellow perimetry were worse than those obtained using white-on-white perimetry (–1.26 dB right, –1.83 dB left). Optical coherence tomography revealed decreased retinal nerve fiber layer thickness in both eyes. Blue-on-yellow perimetry is useful for the detection of visual field disturbances in patients with optic neuropathy.Keywords: optic neuropathy, blue-on-yellow perimetry, white-on-white perimetry, optical coherence tomography, retinal thickness.Makino SDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2013, Iss default, Pp 1319-1323 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Makino S Utility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy |
description |
Shinji MakinoDepartment of Ophthalmology, Jichi Medical University, Shimotsuke, Tochigi, JapanAbstract: A 68-year-old woman with bilateral idiopathic optic neuropathy was examined using blue-on-yellow perimetry. Best-corrected visual acuity was 0.5 and 0.6 in her right and left eyes, respectively. Visual field testing with a Goldmann perimeter showed constriction of the I/2 e isopter in both eyes. With regard to mean deviation, the results (–13.18 dB right, –10.01 dB left) of blue-on-yellow perimetry were worse than those obtained using white-on-white perimetry (–1.26 dB right, –1.83 dB left). Optical coherence tomography revealed decreased retinal nerve fiber layer thickness in both eyes. Blue-on-yellow perimetry is useful for the detection of visual field disturbances in patients with optic neuropathy.Keywords: optic neuropathy, blue-on-yellow perimetry, white-on-white perimetry, optical coherence tomography, retinal thickness. |
format |
article |
author |
Makino S |
author_facet |
Makino S |
author_sort |
Makino S |
title |
Utility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy |
title_short |
Utility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy |
title_full |
Utility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy |
title_fullStr |
Utility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy |
title_full_unstemmed |
Utility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy |
title_sort |
utility of blue-on-yellow perimetry in the evaluation of patients with idiopathic optic neuropathy |
publisher |
Dove Medical Press |
publishDate |
2013 |
url |
https://doaj.org/article/a6aa3015d25f43be89ee5513cae0d5db |
work_keys_str_mv |
AT makinos utilityofblueonyellowperimetryintheevaluationofpatientswithidiopathicopticneuropathy |
_version_ |
1718401095867301888 |