Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study
Gérard Guiffant,1 Jean Jacques Durussel,1 Patrice Flaud,1 Laurent Royon,1 Pierre Yves Marcy,2 Jacques Merckx1,31University Paris Diderot, Paris, France; 2Radiodiagnosis and Interventional Radiology Department, Caen, France; 3University Teaching Hospital Necker-Enfants Malades, Paris, Fran...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/a74547dd57c747d78ba631c13e275a86 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:a74547dd57c747d78ba631c13e275a86 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a74547dd57c747d78ba631c13e275a862021-12-02T11:27:13ZPower port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study1179-1470https://doaj.org/article/a74547dd57c747d78ba631c13e275a862013-09-01T00:00:00Zhttp://www.dovepress.com/power-port-contrast-medium-flushing-and-trapping-impact-of-temperature-a14254https://doaj.org/toc/1179-1470Gérard Guiffant,1 Jean Jacques Durussel,1 Patrice Flaud,1 Laurent Royon,1 Pierre Yves Marcy,2 Jacques Merckx1,31University Paris Diderot, Paris, France; 2Radiodiagnosis and Interventional Radiology Department, Caen, France; 3University Teaching Hospital Necker-Enfants Malades, Paris, FrancePurpose: The use of totally implantable venous access devices (TIVADs) certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter?Results: The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on.Conclusion: We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice.Keywords: contrast medium, implantable ports, totally implantable venous access devices (TIVADs), flushing, obstruction, prevention, central linesGuiffant GDurussel JJFlaud PRoyon LMarcy PYMerckx JDove Medical PressarticleMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol 2013, Iss default, Pp 133-140 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medical technology R855-855.5 |
spellingShingle |
Medical technology R855-855.5 Guiffant G Durussel JJ Flaud P Royon L Marcy PY Merckx J Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study |
description |
Gérard Guiffant,1 Jean Jacques Durussel,1 Patrice Flaud,1 Laurent Royon,1 Pierre Yves Marcy,2 Jacques Merckx1,31University Paris Diderot, Paris, France; 2Radiodiagnosis and Interventional Radiology Department, Caen, France; 3University Teaching Hospital Necker-Enfants Malades, Paris, FrancePurpose: The use of totally implantable venous access devices (TIVADs) certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter?Results: The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on.Conclusion: We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice.Keywords: contrast medium, implantable ports, totally implantable venous access devices (TIVADs), flushing, obstruction, prevention, central lines |
format |
article |
author |
Guiffant G Durussel JJ Flaud P Royon L Marcy PY Merckx J |
author_facet |
Guiffant G Durussel JJ Flaud P Royon L Marcy PY Merckx J |
author_sort |
Guiffant G |
title |
Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study |
title_short |
Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study |
title_full |
Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study |
title_fullStr |
Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study |
title_full_unstemmed |
Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study |
title_sort |
power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study |
publisher |
Dove Medical Press |
publishDate |
2013 |
url |
https://doaj.org/article/a74547dd57c747d78ba631c13e275a86 |
work_keys_str_mv |
AT guiffantg powerportcontrastmediumflushingandtrappingimpactoftemperatureaninvitroexperimentalstudy AT durusseljj powerportcontrastmediumflushingandtrappingimpactoftemperatureaninvitroexperimentalstudy AT flaudp powerportcontrastmediumflushingandtrappingimpactoftemperatureaninvitroexperimentalstudy AT royonl powerportcontrastmediumflushingandtrappingimpactoftemperatureaninvitroexperimentalstudy AT marcypy powerportcontrastmediumflushingandtrappingimpactoftemperatureaninvitroexperimentalstudy AT merckxj powerportcontrastmediumflushingandtrappingimpactoftemperatureaninvitroexperimentalstudy |
_version_ |
1718395955349291008 |