Towards a Living Lab for Enhanced Thermal Comfort and Air Quality: Analyses of Standard Occupancy, Weather Extremes, and COVID-19 Pandemic

Maintaining indoor environmental (IEQ) quality is a key priority in educational buildings. However, most studies rely on outdoor measurements or evaluate limited spatial coverage and time periods that focus on standard occupancy and environmental conditions which makes it hard to establish causality...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Giulia Ulpiani, Negin Nazarian, Fuyu Zhang, Christopher J. Pettit
Formato: article
Lenguaje:EN
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://doaj.org/article/a747db95c067417489293aa32da18bd9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:a747db95c067417489293aa32da18bd9
record_format dspace
spelling oai:doaj.org-article:a747db95c067417489293aa32da18bd92021-12-01T01:54:43ZTowards a Living Lab for Enhanced Thermal Comfort and Air Quality: Analyses of Standard Occupancy, Weather Extremes, and COVID-19 Pandemic2296-665X10.3389/fenvs.2021.725974https://doaj.org/article/a747db95c067417489293aa32da18bd92021-11-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fenvs.2021.725974/fullhttps://doaj.org/toc/2296-665XMaintaining indoor environmental (IEQ) quality is a key priority in educational buildings. However, most studies rely on outdoor measurements or evaluate limited spatial coverage and time periods that focus on standard occupancy and environmental conditions which makes it hard to establish causality and resilience limits. To address this, a fine-grained, low-cost, multi-parameter IOT sensor network was deployed to fully depict the spatial heterogeneity and temporal variability of environmental quality in an educational building in Sydney. The building was particularly selected as it represents a multi-use university facility that relies on passive ventilation strategies, and therefore suitable for establishing a living lab for integrating innovative IoT sensing technologies. IEQ analyses focused on 15 months of measurements, spanning standard occupancy of the building as well as the Black Summer bushfires in 2019, and the COVID-19 lockdown. The role of room characteristics, room use, season, weather extremes, and occupancy levels were disclosed via statistical analysis including mutual information analysis of linear and non-linear correlations and used to generate site-specific re-design guidelines. Overall, we found that 1) passive ventilation systems based on manual interventions are most likely associated with sub-optimum environmental quality and extreme variability linked to occupancy patterns, 2) normally closed environments tend to get very unhealthy under periods of extreme pollution and intermittent/protracted disuse, 3) the elevation and floor level in addition to room use were found to be significant conditional variables in determining heat and pollutants accumulation, presumably due to the synergy between local sources and vertical transport mechanisms. Most IEQ inefficiencies and health threats could be likely mitigated by implementing automated controls and smart logics to maintain adequate cross ventilation, prioritizing building airtightness improvement, and appropriate filtration techniques. This study supports the need for continuous and capillary monitoring of different occupied spaces in educational buildings to compensate for less perceivable threats, identify the room for improvement, and move towards healthy and future-proof learning environments.Giulia UlpianiGiulia UlpianiNegin NazarianNegin NazarianNegin NazarianFuyu ZhangChristopher J. PettitChristopher J. PettitFrontiers Media S.A.articleenvironmental sensing and monitoringthermal comfortindoor air qualityInternet of Thingsliving labCOVID-19Environmental sciencesGE1-350ENFrontiers in Environmental Science, Vol 9 (2021)
institution DOAJ
collection DOAJ
language EN
topic environmental sensing and monitoring
thermal comfort
indoor air quality
Internet of Things
living lab
COVID-19
Environmental sciences
GE1-350
spellingShingle environmental sensing and monitoring
thermal comfort
indoor air quality
Internet of Things
living lab
COVID-19
Environmental sciences
GE1-350
Giulia Ulpiani
Giulia Ulpiani
Negin Nazarian
Negin Nazarian
Negin Nazarian
Fuyu Zhang
Christopher J. Pettit
Christopher J. Pettit
Towards a Living Lab for Enhanced Thermal Comfort and Air Quality: Analyses of Standard Occupancy, Weather Extremes, and COVID-19 Pandemic
description Maintaining indoor environmental (IEQ) quality is a key priority in educational buildings. However, most studies rely on outdoor measurements or evaluate limited spatial coverage and time periods that focus on standard occupancy and environmental conditions which makes it hard to establish causality and resilience limits. To address this, a fine-grained, low-cost, multi-parameter IOT sensor network was deployed to fully depict the spatial heterogeneity and temporal variability of environmental quality in an educational building in Sydney. The building was particularly selected as it represents a multi-use university facility that relies on passive ventilation strategies, and therefore suitable for establishing a living lab for integrating innovative IoT sensing technologies. IEQ analyses focused on 15 months of measurements, spanning standard occupancy of the building as well as the Black Summer bushfires in 2019, and the COVID-19 lockdown. The role of room characteristics, room use, season, weather extremes, and occupancy levels were disclosed via statistical analysis including mutual information analysis of linear and non-linear correlations and used to generate site-specific re-design guidelines. Overall, we found that 1) passive ventilation systems based on manual interventions are most likely associated with sub-optimum environmental quality and extreme variability linked to occupancy patterns, 2) normally closed environments tend to get very unhealthy under periods of extreme pollution and intermittent/protracted disuse, 3) the elevation and floor level in addition to room use were found to be significant conditional variables in determining heat and pollutants accumulation, presumably due to the synergy between local sources and vertical transport mechanisms. Most IEQ inefficiencies and health threats could be likely mitigated by implementing automated controls and smart logics to maintain adequate cross ventilation, prioritizing building airtightness improvement, and appropriate filtration techniques. This study supports the need for continuous and capillary monitoring of different occupied spaces in educational buildings to compensate for less perceivable threats, identify the room for improvement, and move towards healthy and future-proof learning environments.
format article
author Giulia Ulpiani
Giulia Ulpiani
Negin Nazarian
Negin Nazarian
Negin Nazarian
Fuyu Zhang
Christopher J. Pettit
Christopher J. Pettit
author_facet Giulia Ulpiani
Giulia Ulpiani
Negin Nazarian
Negin Nazarian
Negin Nazarian
Fuyu Zhang
Christopher J. Pettit
Christopher J. Pettit
author_sort Giulia Ulpiani
title Towards a Living Lab for Enhanced Thermal Comfort and Air Quality: Analyses of Standard Occupancy, Weather Extremes, and COVID-19 Pandemic
title_short Towards a Living Lab for Enhanced Thermal Comfort and Air Quality: Analyses of Standard Occupancy, Weather Extremes, and COVID-19 Pandemic
title_full Towards a Living Lab for Enhanced Thermal Comfort and Air Quality: Analyses of Standard Occupancy, Weather Extremes, and COVID-19 Pandemic
title_fullStr Towards a Living Lab for Enhanced Thermal Comfort and Air Quality: Analyses of Standard Occupancy, Weather Extremes, and COVID-19 Pandemic
title_full_unstemmed Towards a Living Lab for Enhanced Thermal Comfort and Air Quality: Analyses of Standard Occupancy, Weather Extremes, and COVID-19 Pandemic
title_sort towards a living lab for enhanced thermal comfort and air quality: analyses of standard occupancy, weather extremes, and covid-19 pandemic
publisher Frontiers Media S.A.
publishDate 2021
url https://doaj.org/article/a747db95c067417489293aa32da18bd9
work_keys_str_mv AT giuliaulpiani towardsalivinglabforenhancedthermalcomfortandairqualityanalysesofstandardoccupancyweatherextremesandcovid19pandemic
AT giuliaulpiani towardsalivinglabforenhancedthermalcomfortandairqualityanalysesofstandardoccupancyweatherextremesandcovid19pandemic
AT neginnazarian towardsalivinglabforenhancedthermalcomfortandairqualityanalysesofstandardoccupancyweatherextremesandcovid19pandemic
AT neginnazarian towardsalivinglabforenhancedthermalcomfortandairqualityanalysesofstandardoccupancyweatherextremesandcovid19pandemic
AT neginnazarian towardsalivinglabforenhancedthermalcomfortandairqualityanalysesofstandardoccupancyweatherextremesandcovid19pandemic
AT fuyuzhang towardsalivinglabforenhancedthermalcomfortandairqualityanalysesofstandardoccupancyweatherextremesandcovid19pandemic
AT christopherjpettit towardsalivinglabforenhancedthermalcomfortandairqualityanalysesofstandardoccupancyweatherextremesandcovid19pandemic
AT christopherjpettit towardsalivinglabforenhancedthermalcomfortandairqualityanalysesofstandardoccupancyweatherextremesandcovid19pandemic
_version_ 1718405980028403712