DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS
This paper deals with the determination of analytical calculation error of magnetic field of high-voltage cable lines in two-point bonded cable shields caused by non-uniformity of the current distribution in the shields. The relative error is determined by comparing numerical calculation of magnetic...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN RU UK |
Publicado: |
National Technical University "Kharkiv Polytechnic Institute"
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/a7b8ae6229964d24ad9a9b7f5de119ef |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:a7b8ae6229964d24ad9a9b7f5de119ef |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a7b8ae6229964d24ad9a9b7f5de119ef2021-12-02T16:30:33ZDETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS10.20998/2074-272X.2017.3.042074-272X2309-3404https://doaj.org/article/a7b8ae6229964d24ad9a9b7f5de119ef2017-06-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2017.3.04/100685https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404This paper deals with the determination of analytical calculation error of magnetic field of high-voltage cable lines in two-point bonded cable shields caused by non-uniformity of the current distribution in the shields. The relative error is determined by comparing numerical calculation of magnetic field obtained in the COMSOL Multiphysics software with the analytical one. It is shown that the maximum value of relative error does not exceed 8 %. The obtained error values are verified by testing the numerical calculation and confirmed by results of experiment. In paper proves the correctness of the analytical calculation of magnetic field of cable lines at the points of its normalization, which is carried out without taking into account the non-uniform current distribution in the cable shields. A. O. TkachenkoNational Technical University "Kharkiv Polytechnic Institute"articlecable linecable shieldbonded shieldsmagnetic fieldcalculation errorElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 3, Pp 27-31 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN RU UK |
topic |
cable line cable shield bonded shields magnetic field calculation error Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
cable line cable shield bonded shields magnetic field calculation error Electrical engineering. Electronics. Nuclear engineering TK1-9971 A. O. Tkachenko DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS |
description |
This paper deals with the determination of analytical calculation error of magnetic field of high-voltage cable lines in two-point bonded cable shields caused by non-uniformity of the current distribution in the shields. The relative error is determined by comparing numerical calculation of magnetic field obtained in the COMSOL Multiphysics software with the analytical one. It is shown that the maximum value of relative error does not exceed 8 %. The obtained error values are verified by testing the numerical calculation and confirmed by results of experiment. In paper proves the correctness of the analytical calculation of magnetic field of cable lines at the points of its normalization, which is carried out without taking into account the non-uniform current distribution in the cable shields. |
format |
article |
author |
A. O. Tkachenko |
author_facet |
A. O. Tkachenko |
author_sort |
A. O. Tkachenko |
title |
DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS |
title_short |
DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS |
title_full |
DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS |
title_fullStr |
DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS |
title_full_unstemmed |
DETERMINATION OF ANALYTICAL CALCULATION ERROR OF MAGNETIC FIELD OF HIGH-VOLTAGE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS CAUSED BY NON-UNIFORM CURRENT DISTRIBUTION IN THE SHIELDS |
title_sort |
determination of analytical calculation error of magnetic field of high-voltage cable lines with two-point bonded cable shields caused by non-uniform current distribution in the shields |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
publishDate |
2017 |
url |
https://doaj.org/article/a7b8ae6229964d24ad9a9b7f5de119ef |
work_keys_str_mv |
AT aotkachenko determinationofanalyticalcalculationerrorofmagneticfieldofhighvoltagecablelineswithtwopointbondedcableshieldscausedbynonuniformcurrentdistributionintheshields |
_version_ |
1718383947650433024 |