Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy

Na Ri Park, Jun Hyung Moon, Jeong Kyu LeeDepartment of Ophthalmology, College of Medicine, Chung-Ang University Hospital, Dongjak-gu, Seoul, KoreaObjective: To compare exophthalmometry measured by Hertel exophthalmometer versus computed tomography (CT) scan.Methods: For this study, 133 patients with...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Park NR, Moon JH, Lee JK
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://doaj.org/article/a80cde243a694cf786a85b07746b07cf
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:a80cde243a694cf786a85b07746b07cf
record_format dspace
spelling oai:doaj.org-article:a80cde243a694cf786a85b07746b07cf2021-12-02T07:46:19ZHertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy1177-5483https://doaj.org/article/a80cde243a694cf786a85b07746b07cf2019-08-01T00:00:00Zhttps://www.dovepress.com/hertel-exophthalmometer-versus-computed-tomography-scan-in-proptosis-e-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Na Ri Park, Jun Hyung Moon, Jeong Kyu LeeDepartment of Ophthalmology, College of Medicine, Chung-Ang University Hospital, Dongjak-gu, Seoul, KoreaObjective: To compare exophthalmometry measured by Hertel exophthalmometer versus computed tomography (CT) scan.Methods: For this study, 133 patients with thyroid-associated orbitopathy (TAO) were analyzed retrospectively. Two experienced clinical observers independently measured proptosis using a Hertel exophthalmometer. The CT approaches used to measure proptosis included two previous methods and one new method. Method 1 used both lateral orbital rims–corneal surface in the axial plane, method 2 used lateral to medial orbital rims–corneal surface in the axial plane, and method 3 used superior to inferior orbital rims–corneal surface in the sagittal plane (new method). Patients were separated into two groups based on 2-mm differences in proptosis between eyes. Correlation analysis was performed to find the association between Hertel and CT values.Results: The Pearson’s coefficient (r) was 0.727 for Hertel exophthalmometry and CT method 1, 0.712 for Hertel and CT method 2, and 0.623 for Hertel and CT method 3. For patients with eye proptosis differences larger than 2 mm between eyes, Pearson’s coefficient (r) was 0.495 for Hertel exophthalmometry and CT method 1, 0.634 for Hertel and CT method 2, and 0.635 for Hertel and CT method 3.Conclusion: The three CT methods mentioned above had statistically significant relationships with Hertel exophthalmometry. Methods 2 and 3, which measured both eyes through different cut sections, had a significant relationship with Hertel values with eye proptosis differences larger than 2 mm. Thus, the new additive method may be effective for measuring proptosis in patients with differences greater than 2 mm between eyes.Keywords: orbital disease, exophthalmos, thyroid-associated orbitopathyPark NRMoon JHLee JKDove Medical PressarticleOrbital DiseaseExophthalmosGraves OphthalmopathyOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 1461-1467 (2019)
institution DOAJ
collection DOAJ
language EN
topic Orbital Disease
Exophthalmos
Graves Ophthalmopathy
Ophthalmology
RE1-994
spellingShingle Orbital Disease
Exophthalmos
Graves Ophthalmopathy
Ophthalmology
RE1-994
Park NR
Moon JH
Lee JK
Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy
description Na Ri Park, Jun Hyung Moon, Jeong Kyu LeeDepartment of Ophthalmology, College of Medicine, Chung-Ang University Hospital, Dongjak-gu, Seoul, KoreaObjective: To compare exophthalmometry measured by Hertel exophthalmometer versus computed tomography (CT) scan.Methods: For this study, 133 patients with thyroid-associated orbitopathy (TAO) were analyzed retrospectively. Two experienced clinical observers independently measured proptosis using a Hertel exophthalmometer. The CT approaches used to measure proptosis included two previous methods and one new method. Method 1 used both lateral orbital rims–corneal surface in the axial plane, method 2 used lateral to medial orbital rims–corneal surface in the axial plane, and method 3 used superior to inferior orbital rims–corneal surface in the sagittal plane (new method). Patients were separated into two groups based on 2-mm differences in proptosis between eyes. Correlation analysis was performed to find the association between Hertel and CT values.Results: The Pearson’s coefficient (r) was 0.727 for Hertel exophthalmometry and CT method 1, 0.712 for Hertel and CT method 2, and 0.623 for Hertel and CT method 3. For patients with eye proptosis differences larger than 2 mm between eyes, Pearson’s coefficient (r) was 0.495 for Hertel exophthalmometry and CT method 1, 0.634 for Hertel and CT method 2, and 0.635 for Hertel and CT method 3.Conclusion: The three CT methods mentioned above had statistically significant relationships with Hertel exophthalmometry. Methods 2 and 3, which measured both eyes through different cut sections, had a significant relationship with Hertel values with eye proptosis differences larger than 2 mm. Thus, the new additive method may be effective for measuring proptosis in patients with differences greater than 2 mm between eyes.Keywords: orbital disease, exophthalmos, thyroid-associated orbitopathy
format article
author Park NR
Moon JH
Lee JK
author_facet Park NR
Moon JH
Lee JK
author_sort Park NR
title Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy
title_short Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy
title_full Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy
title_fullStr Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy
title_full_unstemmed Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy
title_sort hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy
publisher Dove Medical Press
publishDate 2019
url https://doaj.org/article/a80cde243a694cf786a85b07746b07cf
work_keys_str_mv AT parknr hertelexophthalmometerversuscomputedtomographyscaninproptosisestimationinthyroidassociatedorbitopathy
AT moonjh hertelexophthalmometerversuscomputedtomographyscaninproptosisestimationinthyroidassociatedorbitopathy
AT leejk hertelexophthalmometerversuscomputedtomographyscaninproptosisestimationinthyroidassociatedorbitopathy
_version_ 1718399179421646848