Comparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study

Abstract The resection of nodules by thoracoscopic surgery is difficult because the nodules may be hard to identify. Preoperative localization of pulmonary nodules is widely used in the clinic. In this study, we retrospectively compared CT-guided hook wire localization and electromagnetic navigation...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yu Tian, Cong Wang, Weiming Yue, Ming Lu, Hui Tian
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2020
Materias:
R
Q
Acceso en línea:https://doaj.org/article/a84005ab85974059a27547f6953ffc9d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:a84005ab85974059a27547f6953ffc9d
record_format dspace
spelling oai:doaj.org-article:a84005ab85974059a27547f6953ffc9d2021-12-02T15:11:53ZComparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study10.1038/s41598-020-78146-z2045-2322https://doaj.org/article/a84005ab85974059a27547f6953ffc9d2020-12-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-78146-zhttps://doaj.org/toc/2045-2322Abstract The resection of nodules by thoracoscopic surgery is difficult because the nodules may be hard to identify. Preoperative localization of pulmonary nodules is widely used in the clinic. In this study, we retrospectively compared CT-guided hook wire localization and electromagnetic navigation bronchoscopy (ENB) localization of small pulmonary nodules before resection. Patients who underwent localization with CT-guided hook wire or ENB followed by video-assisted thoracoscopic surgery (VATS) at Qilu Hospital of Shandong University between January 2016 and December 2019 were retrospectively included. Clinical parameters, complication and failure rate, and localization time were compared between two groups. A total of 157 patients underwent the localization procedure successfully. Pulmonary nodules were localized by CT-guided hook wire in 105 patients and by ENB in 52 patients. The nodule size in ENB group was smaller than that in CT-guided localization group (P < 0.001). Both CT-guided localization and ENB localization were well tolerated in all patients, while ENB localization leaded to less complications (P = 0.0058). In CT-guided localization group, 6 patients failed to be located while none failed in ENB group (P = 0.079). The procedure time was 15.15 ± 3.70 min for CT-guided localization and 21.29 ± 4.00 min for ENB localization (P < 0.001). CT-guided localization is simple and feasible for uncertain pulmonary nodules before surgery. ENB localization could identify small lung nodules with high accuracy and achieve lower incidence of complications.Yu TianCong WangWeiming YueMing LuHui TianNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 10, Iss 1, Pp 1-7 (2020)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Yu Tian
Cong Wang
Weiming Yue
Ming Lu
Hui Tian
Comparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study
description Abstract The resection of nodules by thoracoscopic surgery is difficult because the nodules may be hard to identify. Preoperative localization of pulmonary nodules is widely used in the clinic. In this study, we retrospectively compared CT-guided hook wire localization and electromagnetic navigation bronchoscopy (ENB) localization of small pulmonary nodules before resection. Patients who underwent localization with CT-guided hook wire or ENB followed by video-assisted thoracoscopic surgery (VATS) at Qilu Hospital of Shandong University between January 2016 and December 2019 were retrospectively included. Clinical parameters, complication and failure rate, and localization time were compared between two groups. A total of 157 patients underwent the localization procedure successfully. Pulmonary nodules were localized by CT-guided hook wire in 105 patients and by ENB in 52 patients. The nodule size in ENB group was smaller than that in CT-guided localization group (P < 0.001). Both CT-guided localization and ENB localization were well tolerated in all patients, while ENB localization leaded to less complications (P = 0.0058). In CT-guided localization group, 6 patients failed to be located while none failed in ENB group (P = 0.079). The procedure time was 15.15 ± 3.70 min for CT-guided localization and 21.29 ± 4.00 min for ENB localization (P < 0.001). CT-guided localization is simple and feasible for uncertain pulmonary nodules before surgery. ENB localization could identify small lung nodules with high accuracy and achieve lower incidence of complications.
format article
author Yu Tian
Cong Wang
Weiming Yue
Ming Lu
Hui Tian
author_facet Yu Tian
Cong Wang
Weiming Yue
Ming Lu
Hui Tian
author_sort Yu Tian
title Comparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study
title_short Comparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study
title_full Comparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study
title_fullStr Comparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study
title_full_unstemmed Comparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study
title_sort comparison of computed tomographic imaging-guided hook wire localization and electromagnetic navigation bronchoscope localization in the resection of pulmonary nodules: a retrospective cohort study
publisher Nature Portfolio
publishDate 2020
url https://doaj.org/article/a84005ab85974059a27547f6953ffc9d
work_keys_str_mv AT yutian comparisonofcomputedtomographicimagingguidedhookwirelocalizationandelectromagneticnavigationbronchoscopelocalizationintheresectionofpulmonarynodulesaretrospectivecohortstudy
AT congwang comparisonofcomputedtomographicimagingguidedhookwirelocalizationandelectromagneticnavigationbronchoscopelocalizationintheresectionofpulmonarynodulesaretrospectivecohortstudy
AT weimingyue comparisonofcomputedtomographicimagingguidedhookwirelocalizationandelectromagneticnavigationbronchoscopelocalizationintheresectionofpulmonarynodulesaretrospectivecohortstudy
AT minglu comparisonofcomputedtomographicimagingguidedhookwirelocalizationandelectromagneticnavigationbronchoscopelocalizationintheresectionofpulmonarynodulesaretrospectivecohortstudy
AT huitian comparisonofcomputedtomographicimagingguidedhookwirelocalizationandelectromagneticnavigationbronchoscopelocalizationintheresectionofpulmonarynodulesaretrospectivecohortstudy
_version_ 1718387650626322432