Comparison of penetrating femtosecond laser-assisted astigmatic keratotomy and toric intraocular lens implantation for correction of astigmatism in cataract surgery

Abstract This study tried to compare the clinical outcomes of femtosecond laser-assisted astigmatic keratotomy (FSAK) and toric intraocular lens (IOL) implantation for astigmatism correction and identify factors affecting the efficacy of FSAK and toric IOL implantation in astigmatism correction. Thi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Hoon Noh, Young-Sik Yoo, Kyoung Yoon Shin, Dong Hui Lim, Tae-Young Chung
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/a840f2647a0a47308ec8369194db26b7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Abstract This study tried to compare the clinical outcomes of femtosecond laser-assisted astigmatic keratotomy (FSAK) and toric intraocular lens (IOL) implantation for astigmatism correction and identify factors affecting the efficacy of FSAK and toric IOL implantation in astigmatism correction. This retrospective case series comprised patients with corneal astigmatism ranging between 0.5 D and 4.5 D. Patients underwent FSAK or toric IOL implantation for cataract treatment and correction of astigmatism at the Samsung Medical Center, a tertiary surgical center, between April 2016 and December 2018. All patients underwent examination before and at three months after the surgery for comparative evaluation of refractive astigmatism, corneal high order aberrations and irregularity index. The astigmatism correction was analyzed by the Alpins method. Subgroup analysis of preoperative factors was based on the extent of target-induced astigmatism (TIA), the degree of astigmatism, and astigmatism classification based on topography. Thirty-one eyes underwent toric IOL implantation and 35 eyes underwent FSAK. The refractive astigmatism was significantly decreased in both toric IOL (P = 0.000) and FSAK group (P = 0.003). The correction index (CI) of refractive astigmatism was 0.84 ± 0.39 in the toric IOL and 0.71 ± 0.60 in the FSAK group. There was no difference between the two groups (P = 0.337). The CI of the FSAK group was significantly lower than in the toric IOL group when TIA was more than 1.5 D (P = 0.006), when correcting against-the-rule (P = 0.017), and limbus-to-limbus astigmatism (P = 0.008). In conclusion, toric IOL implantation is an effective and safe procedure for correcting preoperative astigmatism in cataract surgery in the short-term observation.