A novel parameter derived from post-processing procedure of dual energy CT for identification of gout
Abstract ROI analysis is frequently used for obtaining acid content on rapid-kV-switching dual energy CT (DECT), providing inadequate accuracy. A new parameter derived from post-processing procedure, maximum lower limit with stain visible (MLLSV), was used by us to diagnose gout. 30 gout patients an...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/a9b70129afd64ebca8a87c7d6185b3f4 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:a9b70129afd64ebca8a87c7d6185b3f4 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a9b70129afd64ebca8a87c7d6185b3f42021-11-08T10:55:59ZA novel parameter derived from post-processing procedure of dual energy CT for identification of gout10.1038/s41598-021-01100-02045-2322https://doaj.org/article/a9b70129afd64ebca8a87c7d6185b3f42021-11-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-01100-0https://doaj.org/toc/2045-2322Abstract ROI analysis is frequently used for obtaining acid content on rapid-kV-switching dual energy CT (DECT), providing inadequate accuracy. A new parameter derived from post-processing procedure, maximum lower limit with stain visible (MLLSV), was used by us to diagnose gout. 30 gout patients and 20 healthy volunteers were analyzed by using MLLSV. MLLSV was defined as the maximum lower limit of display window allowing only one stained site visible. Radiologists were asked to continuously increase the lower limit of display window of uric acid to decrease number of stained sites until the last stained site disappeared. MLLSV obtained by this way was compared between gout patients and volunteers. Receiver operating characteristic (ROC) curve was used to determine the performance. MLLSV of gout patients was significantly higher than that of volunteers (1373.3 ± 23.0 mg/cm3 vs. 1315.4 ± 20.7 mg/cm3, p = 0.000). The area under ROC curve of MLLSV was 0.993 in identifying gout. When using the optimal cutoff of 1342 mg/cm3, the sensitivity and specificity of MLLSV in identification of gout were 96.7% and 95% respectively. MLLSV derived from post-processing procedure of DECT is useful in discriminating gout patients from healthy people.Chunlin XiangHongyan ZhangGang WuNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-7 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Chunlin Xiang Hongyan Zhang Gang Wu A novel parameter derived from post-processing procedure of dual energy CT for identification of gout |
description |
Abstract ROI analysis is frequently used for obtaining acid content on rapid-kV-switching dual energy CT (DECT), providing inadequate accuracy. A new parameter derived from post-processing procedure, maximum lower limit with stain visible (MLLSV), was used by us to diagnose gout. 30 gout patients and 20 healthy volunteers were analyzed by using MLLSV. MLLSV was defined as the maximum lower limit of display window allowing only one stained site visible. Radiologists were asked to continuously increase the lower limit of display window of uric acid to decrease number of stained sites until the last stained site disappeared. MLLSV obtained by this way was compared between gout patients and volunteers. Receiver operating characteristic (ROC) curve was used to determine the performance. MLLSV of gout patients was significantly higher than that of volunteers (1373.3 ± 23.0 mg/cm3 vs. 1315.4 ± 20.7 mg/cm3, p = 0.000). The area under ROC curve of MLLSV was 0.993 in identifying gout. When using the optimal cutoff of 1342 mg/cm3, the sensitivity and specificity of MLLSV in identification of gout were 96.7% and 95% respectively. MLLSV derived from post-processing procedure of DECT is useful in discriminating gout patients from healthy people. |
format |
article |
author |
Chunlin Xiang Hongyan Zhang Gang Wu |
author_facet |
Chunlin Xiang Hongyan Zhang Gang Wu |
author_sort |
Chunlin Xiang |
title |
A novel parameter derived from post-processing procedure of dual energy CT for identification of gout |
title_short |
A novel parameter derived from post-processing procedure of dual energy CT for identification of gout |
title_full |
A novel parameter derived from post-processing procedure of dual energy CT for identification of gout |
title_fullStr |
A novel parameter derived from post-processing procedure of dual energy CT for identification of gout |
title_full_unstemmed |
A novel parameter derived from post-processing procedure of dual energy CT for identification of gout |
title_sort |
novel parameter derived from post-processing procedure of dual energy ct for identification of gout |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/a9b70129afd64ebca8a87c7d6185b3f4 |
work_keys_str_mv |
AT chunlinxiang anovelparameterderivedfrompostprocessingprocedureofdualenergyctforidentificationofgout AT hongyanzhang anovelparameterderivedfrompostprocessingprocedureofdualenergyctforidentificationofgout AT gangwu anovelparameterderivedfrompostprocessingprocedureofdualenergyctforidentificationofgout AT chunlinxiang novelparameterderivedfrompostprocessingprocedureofdualenergyctforidentificationofgout AT hongyanzhang novelparameterderivedfrompostprocessingprocedureofdualenergyctforidentificationofgout AT gangwu novelparameterderivedfrompostprocessingprocedureofdualenergyctforidentificationofgout |
_version_ |
1718442555779055616 |