Performance Research and Optimization of Sound Insulation Hood of Air Compressor Unit
The noise control of a compressor has always been a hot spot in the field of industrial application. In this paper, the air inlet structure of the sound insulation hood of an air compressor unit was studied and improved. Acoustic finite element numerical simulation analysis of the sound insulation h...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/a9d7d97ae78849f7bf5b778c7f3f277d |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:a9d7d97ae78849f7bf5b778c7f3f277d |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:a9d7d97ae78849f7bf5b778c7f3f277d2021-11-11T15:23:48ZPerformance Research and Optimization of Sound Insulation Hood of Air Compressor Unit10.3390/app1121103642076-3417https://doaj.org/article/a9d7d97ae78849f7bf5b778c7f3f277d2021-11-01T00:00:00Zhttps://www.mdpi.com/2076-3417/11/21/10364https://doaj.org/toc/2076-3417The noise control of a compressor has always been a hot spot in the field of industrial application. In this paper, the air inlet structure of the sound insulation hood of an air compressor unit was studied and improved. Acoustic finite element numerical simulation analysis of the sound insulation hood model was carried out using the acoustic software LMS Virtual Lab Acoustics. The simulation results were compared with the experimental data to verify the correctness of the model, and the theoretical results showed a good agreement with the experiment data. The sound insulation performance of the sound insulation hood under different structures was also investigated in this paper. The results show that the main source of unit noise leakage is outward radiation through the air inlet. In addition, the noise at the air inlet of the unit and the overall noise were significantly reduced compared with the traditional sound insulation hood upon installing 120° and 90° diaphragm structures on the inner wall of the air inlet. The optimization results show that the noise reduction effect of the sound insulation hood with a 90° diaphragm structure was better than that with a 120° diaphragm structure.Huagen WuYuqi ShenMengtao LiangJiankang LiuJingjing WuZhuo LiMDPI AGarticlecompressornoisesound insulation hoodTechnologyTEngineering (General). Civil engineering (General)TA1-2040Biology (General)QH301-705.5PhysicsQC1-999ChemistryQD1-999ENApplied Sciences, Vol 11, Iss 10364, p 10364 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
compressor noise sound insulation hood Technology T Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 |
spellingShingle |
compressor noise sound insulation hood Technology T Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 Huagen Wu Yuqi Shen Mengtao Liang Jiankang Liu Jingjing Wu Zhuo Li Performance Research and Optimization of Sound Insulation Hood of Air Compressor Unit |
description |
The noise control of a compressor has always been a hot spot in the field of industrial application. In this paper, the air inlet structure of the sound insulation hood of an air compressor unit was studied and improved. Acoustic finite element numerical simulation analysis of the sound insulation hood model was carried out using the acoustic software LMS Virtual Lab Acoustics. The simulation results were compared with the experimental data to verify the correctness of the model, and the theoretical results showed a good agreement with the experiment data. The sound insulation performance of the sound insulation hood under different structures was also investigated in this paper. The results show that the main source of unit noise leakage is outward radiation through the air inlet. In addition, the noise at the air inlet of the unit and the overall noise were significantly reduced compared with the traditional sound insulation hood upon installing 120° and 90° diaphragm structures on the inner wall of the air inlet. The optimization results show that the noise reduction effect of the sound insulation hood with a 90° diaphragm structure was better than that with a 120° diaphragm structure. |
format |
article |
author |
Huagen Wu Yuqi Shen Mengtao Liang Jiankang Liu Jingjing Wu Zhuo Li |
author_facet |
Huagen Wu Yuqi Shen Mengtao Liang Jiankang Liu Jingjing Wu Zhuo Li |
author_sort |
Huagen Wu |
title |
Performance Research and Optimization of Sound Insulation Hood of Air Compressor Unit |
title_short |
Performance Research and Optimization of Sound Insulation Hood of Air Compressor Unit |
title_full |
Performance Research and Optimization of Sound Insulation Hood of Air Compressor Unit |
title_fullStr |
Performance Research and Optimization of Sound Insulation Hood of Air Compressor Unit |
title_full_unstemmed |
Performance Research and Optimization of Sound Insulation Hood of Air Compressor Unit |
title_sort |
performance research and optimization of sound insulation hood of air compressor unit |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/a9d7d97ae78849f7bf5b778c7f3f277d |
work_keys_str_mv |
AT huagenwu performanceresearchandoptimizationofsoundinsulationhoodofaircompressorunit AT yuqishen performanceresearchandoptimizationofsoundinsulationhoodofaircompressorunit AT mengtaoliang performanceresearchandoptimizationofsoundinsulationhoodofaircompressorunit AT jiankangliu performanceresearchandoptimizationofsoundinsulationhoodofaircompressorunit AT jingjingwu performanceresearchandoptimizationofsoundinsulationhoodofaircompressorunit AT zhuoli performanceresearchandoptimizationofsoundinsulationhoodofaircompressorunit |
_version_ |
1718435383935500288 |