COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE
Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU), which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for pa...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Belitung Raya Foundation
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/aa61368fb7e2485e90d23761c80a36bf |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:aa61368fb7e2485e90d23761c80a36bf |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:aa61368fb7e2485e90d23761c80a36bf2021-12-02T12:51:07ZCOMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE2477-40732477-4073https://doaj.org/article/aa61368fb7e2485e90d23761c80a36bf2017-12-01T00:00:00Zhttp://belitungraya.org/BRP/index.php/bnj/article/view/300https://doaj.org/toc/2477-4073https://doaj.org/toc/2477-4073Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU), which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05). The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT. MuhajiBedjo SantosoPutronoBelitung Raya FoundationarticleEndotracheal TubePressure SuctionOxygen SaturationNursingRT1-120ENBelitung Nursing Journal, Vol 3, Iss 6, Pp 693-696 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Endotracheal Tube Pressure Suction Oxygen Saturation Nursing RT1-120 |
spellingShingle |
Endotracheal Tube Pressure Suction Oxygen Saturation Nursing RT1-120 Muhaji Bedjo Santoso Putrono COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE |
description |
Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU), which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube.
Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube.
Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis.
Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05). The mean difference of oxygen saturation between both groups was 13.157.
Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT.
|
format |
article |
author |
Muhaji Bedjo Santoso Putrono |
author_facet |
Muhaji Bedjo Santoso Putrono |
author_sort |
Muhaji |
title |
COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE |
title_short |
COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE |
title_full |
COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE |
title_fullStr |
COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE |
title_full_unstemmed |
COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE |
title_sort |
comparison of the effectiveness of two levels of suction pressure on oxygen saturation in patients with endotracheal tube |
publisher |
Belitung Raya Foundation |
publishDate |
2017 |
url |
https://doaj.org/article/aa61368fb7e2485e90d23761c80a36bf |
work_keys_str_mv |
AT muhaji comparisonoftheeffectivenessoftwolevelsofsuctionpressureonoxygensaturationinpatientswithendotrachealtube AT bedjosantoso comparisonoftheeffectivenessoftwolevelsofsuctionpressureonoxygensaturationinpatientswithendotrachealtube AT putrono comparisonoftheeffectivenessoftwolevelsofsuctionpressureonoxygensaturationinpatientswithendotrachealtube |
_version_ |
1718393643777130496 |