COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE

Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU), which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for pa...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Muhaji, Bedjo Santoso, Putrono
Formato: article
Lenguaje:EN
Publicado: Belitung Raya Foundation 2017
Materias:
Acceso en línea:https://doaj.org/article/aa61368fb7e2485e90d23761c80a36bf
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:aa61368fb7e2485e90d23761c80a36bf
record_format dspace
spelling oai:doaj.org-article:aa61368fb7e2485e90d23761c80a36bf2021-12-02T12:51:07ZCOMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE2477-40732477-4073https://doaj.org/article/aa61368fb7e2485e90d23761c80a36bf2017-12-01T00:00:00Zhttp://belitungraya.org/BRP/index.php/bnj/article/view/300https://doaj.org/toc/2477-4073https://doaj.org/toc/2477-4073Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU), which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05). The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT. MuhajiBedjo SantosoPutronoBelitung Raya FoundationarticleEndotracheal TubePressure SuctionOxygen SaturationNursingRT1-120ENBelitung Nursing Journal, Vol 3, Iss 6, Pp 693-696 (2017)
institution DOAJ
collection DOAJ
language EN
topic Endotracheal Tube
Pressure Suction
Oxygen Saturation
Nursing
RT1-120
spellingShingle Endotracheal Tube
Pressure Suction
Oxygen Saturation
Nursing
RT1-120
Muhaji
Bedjo Santoso
Putrono
COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE
description Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU), which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05). The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT.
format article
author Muhaji
Bedjo Santoso
Putrono
author_facet Muhaji
Bedjo Santoso
Putrono
author_sort Muhaji
title COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE
title_short COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE
title_full COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE
title_fullStr COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE
title_full_unstemmed COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE
title_sort comparison of the effectiveness of two levels of suction pressure on oxygen saturation in patients with endotracheal tube
publisher Belitung Raya Foundation
publishDate 2017
url https://doaj.org/article/aa61368fb7e2485e90d23761c80a36bf
work_keys_str_mv AT muhaji comparisonoftheeffectivenessoftwolevelsofsuctionpressureonoxygensaturationinpatientswithendotrachealtube
AT bedjosantoso comparisonoftheeffectivenessoftwolevelsofsuctionpressureonoxygensaturationinpatientswithendotrachealtube
AT putrono comparisonoftheeffectivenessoftwolevelsofsuctionpressureonoxygensaturationinpatientswithendotrachealtube
_version_ 1718393643777130496