Perfluorocarbon liquid-assisted intraocular foreign body removal
Cindy Ung, Inês Laíns, Thanos D Papakostas, Safa Rahmani, John B Miller Retina Service, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA Abstract: We describe the benefits of perfluoro-N-octane (PFO), a perfluorocarbon liquid, in the removal of nonmagnetic in...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://doaj.org/article/abdfeebf0d5143459480df361ce01b8c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:abdfeebf0d5143459480df361ce01b8c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:abdfeebf0d5143459480df361ce01b8c2021-12-02T05:59:13ZPerfluorocarbon liquid-assisted intraocular foreign body removal1177-5483https://doaj.org/article/abdfeebf0d5143459480df361ce01b8c2018-06-01T00:00:00Zhttps://www.dovepress.com/perfluorocarbon-liquid-assisted-intraocular-foreign-body-removal-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Cindy Ung, Inês Laíns, Thanos D Papakostas, Safa Rahmani, John B Miller Retina Service, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA Abstract: We describe the benefits of perfluoro-N-octane (PFO), a perfluorocarbon liquid, in the removal of nonmagnetic intraocular foreign bodies (IOFBs) from the macula and posterior segment. Two consecutive cases of posterior segment IOFB were reviewed. An 18-year-old male presented to the emergency room after a motor vehicle accident with a zone 1 open globe injury and large glass IOFB in the left eye. A 53-year-old male presented to the emergency room with a history of a 3-week delayed presentation of a zone 1 open globe injury from a nail to the right eye. He was found to have a metallic IOFB. In both cases, PFO was used to slide the nonmagnetic IOFBs outside of the macula for safer retrieval. PFO was also able to protect the posterior pole from IOFB drops during early attempts at removal. PFO can be a useful surgical adjunct to pars plana vitrectomy in the removal of certain nonmagnetic IOFBs. Keywords: intraocular foreign body, trauma, open globe, perfluorocarbon liquidUng CLaíns IPapakostas TDRahmani SMiller JBDove Medical PressarticleIntraocular foreign bodytraumaopen globeOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 1099-1104 (2018) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Intraocular foreign body trauma open globe Ophthalmology RE1-994 |
spellingShingle |
Intraocular foreign body trauma open globe Ophthalmology RE1-994 Ung C Laíns I Papakostas TD Rahmani S Miller JB Perfluorocarbon liquid-assisted intraocular foreign body removal |
description |
Cindy Ung, Inês Laíns, Thanos D Papakostas, Safa Rahmani, John B Miller Retina Service, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA Abstract: We describe the benefits of perfluoro-N-octane (PFO), a perfluorocarbon liquid, in the removal of nonmagnetic intraocular foreign bodies (IOFBs) from the macula and posterior segment. Two consecutive cases of posterior segment IOFB were reviewed. An 18-year-old male presented to the emergency room after a motor vehicle accident with a zone 1 open globe injury and large glass IOFB in the left eye. A 53-year-old male presented to the emergency room with a history of a 3-week delayed presentation of a zone 1 open globe injury from a nail to the right eye. He was found to have a metallic IOFB. In both cases, PFO was used to slide the nonmagnetic IOFBs outside of the macula for safer retrieval. PFO was also able to protect the posterior pole from IOFB drops during early attempts at removal. PFO can be a useful surgical adjunct to pars plana vitrectomy in the removal of certain nonmagnetic IOFBs. Keywords: intraocular foreign body, trauma, open globe, perfluorocarbon liquid |
format |
article |
author |
Ung C Laíns I Papakostas TD Rahmani S Miller JB |
author_facet |
Ung C Laíns I Papakostas TD Rahmani S Miller JB |
author_sort |
Ung C |
title |
Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_short |
Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_full |
Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_fullStr |
Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_full_unstemmed |
Perfluorocarbon liquid-assisted intraocular foreign body removal |
title_sort |
perfluorocarbon liquid-assisted intraocular foreign body removal |
publisher |
Dove Medical Press |
publishDate |
2018 |
url |
https://doaj.org/article/abdfeebf0d5143459480df361ce01b8c |
work_keys_str_mv |
AT ungc perfluorocarbonliquidassistedintraocularforeignbodyremoval AT lainsi perfluorocarbonliquidassistedintraocularforeignbodyremoval AT papakostastd perfluorocarbonliquidassistedintraocularforeignbodyremoval AT rahmanis perfluorocarbonliquidassistedintraocularforeignbodyremoval AT millerjb perfluorocarbonliquidassistedintraocularforeignbodyremoval |
_version_ |
1718400128378732544 |