Determination of phenolic compounds in medicinal preparations by galvanostatic coulometry

In this work, the possibility of using reactions of electrogenerated titrants with phenolic compounds was studied and a method for their coulometric determination in medicaments by galvanostatic coulometry was developed. The research objects were: rutin, salicylic acid and drugs containing phenolic...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: N. N. Yaschenko, S. V. Zhitar, E. G. Zinovjeva
Formato: article
Lenguaje:EN
RU
Publicado: Uralʹskij federalʹnyj universitet imeni pervogo Prezidenta Rossii B.N. Elʹcina 2021
Materias:
Acceso en línea:https://doaj.org/article/ad01c494755d476ca977cedb15220e87
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ad01c494755d476ca977cedb15220e87
record_format dspace
spelling oai:doaj.org-article:ad01c494755d476ca977cedb15220e872021-12-01T05:53:11ZDetermination of phenolic compounds in medicinal preparations by galvanostatic coulometry2411-141410.15826/chimtech.2021.8.1.10https://doaj.org/article/ad01c494755d476ca977cedb15220e872021-04-01T00:00:00Zhttps://journals.urfu.ru/index.php/chimtech/article/view/5081https://doaj.org/toc/2411-1414In this work, the possibility of using reactions of electrogenerated titrants with phenolic compounds was studied and a method for their coulometric determination in medicaments by galvanostatic coulometry was developed. The research objects were: rutin, salicylic acid and drugs containing phenolic compounds such as «Ascorutin», «Salicylic Paste» and «Salicylic Ointment» of Russian manufacture. Electrogenerated halogens (Cl2, Br2 and I2) and hexacyanoferrate(III)-ions were used as titrants. It was found that for the quantitative determination of phenolic acids, the optimal reagent is electrogenerated bromine, for rutin - electrogenerated bromine and iodine, and for ascorbic acid - any of the studied electrogenerated titrants (Cl2, Br2, I2 and [Fe(CN)6]3-). The correct definition was checked by the «entered-found» method, the error does not exceed 2%. As experimental studies have shown, our method of coulometric titration with electrogenated bromine and iodine is characterized by good reproducibility of results, expression, accuracy and can be used to determine phenolic compounds in drugs, for example, «Ascorutin» tablets. It should be noted that by our procedure it is possible to determine the spectrum of phenol-containing compounds (rutin, ascorbic and salicylic acids) in drugs without their preliminary separation. Therefore, the coulometric method using electrogenerated titrants can be recommended for the determination of salicylic, ascorbic acids and rutin in dosage forms. The proposed method is accurate and eliminates the experiment error in comparison with the Pharmacopoeic method.N. N. YaschenkoS. V. ZhitarE. G. ZinovjevaUralʹskij federalʹnyj universitet imeni pervogo Prezidenta Rossii B.N. Elʹcina articlegalvanostatic coulometryphenolic compoundsflavonoidsChemistryQD1-999ENRUChimica Techno Acta, Vol 8, Iss 1 (2021)
institution DOAJ
collection DOAJ
language EN
RU
topic galvanostatic coulometry
phenolic compounds
flavonoids
Chemistry
QD1-999
spellingShingle galvanostatic coulometry
phenolic compounds
flavonoids
Chemistry
QD1-999
N. N. Yaschenko
S. V. Zhitar
E. G. Zinovjeva
Determination of phenolic compounds in medicinal preparations by galvanostatic coulometry
description In this work, the possibility of using reactions of electrogenerated titrants with phenolic compounds was studied and a method for their coulometric determination in medicaments by galvanostatic coulometry was developed. The research objects were: rutin, salicylic acid and drugs containing phenolic compounds such as «Ascorutin», «Salicylic Paste» and «Salicylic Ointment» of Russian manufacture. Electrogenerated halogens (Cl2, Br2 and I2) and hexacyanoferrate(III)-ions were used as titrants. It was found that for the quantitative determination of phenolic acids, the optimal reagent is electrogenerated bromine, for rutin - electrogenerated bromine and iodine, and for ascorbic acid - any of the studied electrogenerated titrants (Cl2, Br2, I2 and [Fe(CN)6]3-). The correct definition was checked by the «entered-found» method, the error does not exceed 2%. As experimental studies have shown, our method of coulometric titration with electrogenated bromine and iodine is characterized by good reproducibility of results, expression, accuracy and can be used to determine phenolic compounds in drugs, for example, «Ascorutin» tablets. It should be noted that by our procedure it is possible to determine the spectrum of phenol-containing compounds (rutin, ascorbic and salicylic acids) in drugs without their preliminary separation. Therefore, the coulometric method using electrogenerated titrants can be recommended for the determination of salicylic, ascorbic acids and rutin in dosage forms. The proposed method is accurate and eliminates the experiment error in comparison with the Pharmacopoeic method.
format article
author N. N. Yaschenko
S. V. Zhitar
E. G. Zinovjeva
author_facet N. N. Yaschenko
S. V. Zhitar
E. G. Zinovjeva
author_sort N. N. Yaschenko
title Determination of phenolic compounds in medicinal preparations by galvanostatic coulometry
title_short Determination of phenolic compounds in medicinal preparations by galvanostatic coulometry
title_full Determination of phenolic compounds in medicinal preparations by galvanostatic coulometry
title_fullStr Determination of phenolic compounds in medicinal preparations by galvanostatic coulometry
title_full_unstemmed Determination of phenolic compounds in medicinal preparations by galvanostatic coulometry
title_sort determination of phenolic compounds in medicinal preparations by galvanostatic coulometry
publisher Uralʹskij federalʹnyj universitet imeni pervogo Prezidenta Rossii B.N. Elʹcina
publishDate 2021
url https://doaj.org/article/ad01c494755d476ca977cedb15220e87
work_keys_str_mv AT nnyaschenko determinationofphenoliccompoundsinmedicinalpreparationsbygalvanostaticcoulometry
AT svzhitar determinationofphenoliccompoundsinmedicinalpreparationsbygalvanostaticcoulometry
AT egzinovjeva determinationofphenoliccompoundsinmedicinalpreparationsbygalvanostaticcoulometry
_version_ 1718405497627869184