A Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket

This paper studies the behavior of axially loaded RC columns which are confined with carbon fiber reinforced polymers’ sheet (CFRP) and steel jackets (SJ). The study is based on twelve axially loaded RC columns tested up to failure. It is divided into three schemes based on its strengthening type; e...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ibraheem Rawaa S., Al-Zuhairi Alaa H.
Formato: article
Lenguaje:EN
FR
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/ad3e4166f1c44b0a853eff78c6b5b5c9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ad3e4166f1c44b0a853eff78c6b5b5c9
record_format dspace
spelling oai:doaj.org-article:ad3e4166f1c44b0a853eff78c6b5b5c92021-11-12T11:43:50ZA Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket2267-124210.1051/e3sconf/202131803002https://doaj.org/article/ad3e4166f1c44b0a853eff78c6b5b5c92021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/94/e3sconf_icge2021_03002.pdfhttps://doaj.org/toc/2267-1242This paper studies the behavior of axially loaded RC columns which are confined with carbon fiber reinforced polymers’ sheet (CFRP) and steel jackets (SJ). The study is based on twelve axially loaded RC columns tested up to failure. It is divided into three schemes based on its strengthening type; each scheme has four columns. The main parameters in this study were the compressive strength of the concrete and steel reinforcement ratio. Furthermore, the results of the experimental test showed a substantial enhancement in the column's load-carrying capacity. When compared to the original columns, the CFRP sheet had a significant effect on improving the ductility of the column by increasing the axial deformation by about 59.2 to 95.7%. On the other hand, the SJ contributed mostly to the column load-carrying capacity, which increased the capacity of RC concrete from 75 to 107%; because of its composite action comparing with the CFRP sheet action in which unidirectional lateral confinement is provided. Both methods produced completely different failure modes. The columns strengthened with CFRP sheet failed by rupture occurring in the sheet fibers. The strengthened with SJ failed due to the buckling that occurred in the steel angles due to the direct contact with the head of the column, and crushing in the concrete has occurred.Ibraheem Rawaa S.Al-Zuhairi Alaa H.EDP Sciencesarticlestrengtheningsteel jacketcarbon fiber reinforced polymercomposite columnEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 318, p 03002 (2021)
institution DOAJ
collection DOAJ
language EN
FR
topic strengthening
steel jacket
carbon fiber reinforced polymer
composite column
Environmental sciences
GE1-350
spellingShingle strengthening
steel jacket
carbon fiber reinforced polymer
composite column
Environmental sciences
GE1-350
Ibraheem Rawaa S.
Al-Zuhairi Alaa H.
A Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket
description This paper studies the behavior of axially loaded RC columns which are confined with carbon fiber reinforced polymers’ sheet (CFRP) and steel jackets (SJ). The study is based on twelve axially loaded RC columns tested up to failure. It is divided into three schemes based on its strengthening type; each scheme has four columns. The main parameters in this study were the compressive strength of the concrete and steel reinforcement ratio. Furthermore, the results of the experimental test showed a substantial enhancement in the column's load-carrying capacity. When compared to the original columns, the CFRP sheet had a significant effect on improving the ductility of the column by increasing the axial deformation by about 59.2 to 95.7%. On the other hand, the SJ contributed mostly to the column load-carrying capacity, which increased the capacity of RC concrete from 75 to 107%; because of its composite action comparing with the CFRP sheet action in which unidirectional lateral confinement is provided. Both methods produced completely different failure modes. The columns strengthened with CFRP sheet failed by rupture occurring in the sheet fibers. The strengthened with SJ failed due to the buckling that occurred in the steel angles due to the direct contact with the head of the column, and crushing in the concrete has occurred.
format article
author Ibraheem Rawaa S.
Al-Zuhairi Alaa H.
author_facet Ibraheem Rawaa S.
Al-Zuhairi Alaa H.
author_sort Ibraheem Rawaa S.
title A Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket
title_short A Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket
title_full A Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket
title_fullStr A Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket
title_full_unstemmed A Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket
title_sort comparative study on behavior of rc columns strengthened by cfrp and steel jacket
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/ad3e4166f1c44b0a853eff78c6b5b5c9
work_keys_str_mv AT ibraheemrawaas acomparativestudyonbehaviorofrccolumnsstrengthenedbycfrpandsteeljacket
AT alzuhairialaah acomparativestudyonbehaviorofrccolumnsstrengthenedbycfrpandsteeljacket
AT ibraheemrawaas comparativestudyonbehaviorofrccolumnsstrengthenedbycfrpandsteeljacket
AT alzuhairialaah comparativestudyonbehaviorofrccolumnsstrengthenedbycfrpandsteeljacket
_version_ 1718430639081914368