The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study
Aim: Bacterial micro leakage at implant-abutment interface under functional loading is an important factor, may lead to crestal bone loss and affect the long term success of dental implants. Due to the limited studies about the implant systems with a connection of Slip joint design, this study aimed...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Wolters Kluwer Medknow Publications
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/adb823c48d2f4f40b19f6b600a10cb37 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:adb823c48d2f4f40b19f6b600a10cb37 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:adb823c48d2f4f40b19f6b600a10cb372021-11-19T10:59:32ZThe effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study0972-40521998-405710.4103/jips.jips_96_21https://doaj.org/article/adb823c48d2f4f40b19f6b600a10cb372021-01-01T00:00:00Zhttp://www.j-ips.org/article.asp?issn=0972-4052;year=2021;volume=21;issue=4;spage=420;epage=424;aulast=Amjadihttps://doaj.org/toc/0972-4052https://doaj.org/toc/1998-4057Aim: Bacterial micro leakage at implant-abutment interface under functional loading is an important factor, may lead to crestal bone loss and affect the long term success of dental implants. Due to the limited studies about the implant systems with a connection of Slip joint design, this study aimed to evaluate the effect of dynamic loading on bacterial leakage at the implant-abutment interface with slip joint connection. Settings and Design: In vitro- comparative study. Materials and Methods: A total of 20 implants and abutments with slip joint connections (Tapered Screw-Vent, 3.7 mm ×10 mm, Zimmer Dental, USA) was examined and depends on using functional loading were divided into two groups; loaded and unloaded. Initially, 10 μl of Brain Heart Infusion (BHI) culture broth was pipetted to the internal lumen of each implant, then the abutments were tightened to the fixtures and crowns were cemented. In the unloaded group, samples were immersed in E-Coli suspension for 5 days. In the loaded group, samples were immersed in microbial suspension under 500000 cycles using a cyclic load device. Following disconnection of fixtures and abutments, microbial samples were taken from the internal lumen of implants and colonies were counted. Data were analyzed using. Statistical Analysis Used: Mann-Whitney statistical test, SPSS version 24. Results: The mean rate of micro leakage in unloaded and loaded groups was 4000 CFU/ml and 27000 ± 31640 CFU/ml respectively. Bacterial colonies grew in 10% of unloaded samples and 50% of loaded samples. This difference was statistically significant. (P < 0.05) Conclusions: Microbial micro leakage at the implant-abutment interface with slip joint design increased significantly after functional loading.Mehrak AmjadiAzadeh KhajaviNavid YoussefiNegar BarjiniZahra KazemiWolters Kluwer Medknow Publicationsarticlebacterial countdental implant loadingdental implant-abutment interfacemicroleakageDentistryRK1-715ENThe Journal of Indian Prosthodontic Society, Vol 21, Iss 4, Pp 420-424 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
bacterial count dental implant loading dental implant-abutment interface microleakage Dentistry RK1-715 |
spellingShingle |
bacterial count dental implant loading dental implant-abutment interface microleakage Dentistry RK1-715 Mehrak Amjadi Azadeh Khajavi Navid Youssefi Negar Barjini Zahra Kazemi The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study |
description |
Aim: Bacterial micro leakage at implant-abutment interface under functional loading is an important factor, may lead to crestal bone loss and affect the long term success of dental implants. Due to the limited studies about the implant systems with a connection of Slip joint design, this study aimed to evaluate the effect of dynamic loading on bacterial leakage at the implant-abutment interface with slip joint connection.
Settings and Design: In vitro- comparative study.
Materials and Methods: A total of 20 implants and abutments with slip joint connections (Tapered Screw-Vent, 3.7 mm ×10 mm, Zimmer Dental, USA) was examined and depends on using functional loading were divided into two groups; loaded and unloaded. Initially, 10 μl of Brain Heart Infusion (BHI) culture broth was pipetted to the internal lumen of each implant, then the abutments were tightened to the fixtures and crowns were cemented. In the unloaded group, samples were immersed in E-Coli suspension for 5 days. In the loaded group, samples were immersed in microbial suspension under 500000 cycles using a cyclic load device. Following disconnection of fixtures and abutments, microbial samples were taken from the internal lumen of implants and colonies were counted. Data were analyzed using.
Statistical Analysis Used: Mann-Whitney statistical test, SPSS version 24.
Results: The mean rate of micro leakage in unloaded and loaded groups was 4000 CFU/ml and 27000 ± 31640 CFU/ml respectively. Bacterial colonies grew in 10% of unloaded samples and 50% of loaded samples. This difference was statistically significant. (P < 0.05)
Conclusions: Microbial micro leakage at the implant-abutment interface with slip joint design increased significantly after functional loading. |
format |
article |
author |
Mehrak Amjadi Azadeh Khajavi Navid Youssefi Negar Barjini Zahra Kazemi |
author_facet |
Mehrak Amjadi Azadeh Khajavi Navid Youssefi Negar Barjini Zahra Kazemi |
author_sort |
Mehrak Amjadi |
title |
The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study |
title_short |
The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study |
title_full |
The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study |
title_fullStr |
The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study |
title_full_unstemmed |
The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study |
title_sort |
effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: an in vitro study |
publisher |
Wolters Kluwer Medknow Publications |
publishDate |
2021 |
url |
https://doaj.org/article/adb823c48d2f4f40b19f6b600a10cb37 |
work_keys_str_mv |
AT mehrakamjadi theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy AT azadehkhajavi theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy AT navidyoussefi theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy AT negarbarjini theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy AT zahrakazemi theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy AT mehrakamjadi effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy AT azadehkhajavi effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy AT navidyoussefi effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy AT negarbarjini effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy AT zahrakazemi effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy |
_version_ |
1718420151975542784 |