Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions
In this paper, experimental study has been done for temperature distribution in space conditioned with Ventilation Hollow Core Slab (TermoDeck) system. The experiments were carried out on a model room with dimensions of (1m 1.2m 1m) that was built according to a suitable scale factor of (1/4). The...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Al-Khwarizmi College of Engineering – University of Baghdad
2014
|
Materias: | |
Acceso en línea: | https://doaj.org/article/ae02c6b16d4e4c1cabaea8b684b70b3d |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:ae02c6b16d4e4c1cabaea8b684b70b3d |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:ae02c6b16d4e4c1cabaea8b684b70b3d2021-12-02T04:16:22ZUsing TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions1818-11712312-0789https://doaj.org/article/ae02c6b16d4e4c1cabaea8b684b70b3d2014-09-01T00:00:00Zhttp://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/457https://doaj.org/toc/1818-1171https://doaj.org/toc/2312-0789 In this paper, experimental study has been done for temperature distribution in space conditioned with Ventilation Hollow Core Slab (TermoDeck) system. The experiments were carried out on a model room with dimensions of (1m 1.2m 1m) that was built according to a suitable scale factor of (1/4). The temperature distributions was measured by 59 thermocouples fixed in several locations in the test room. Two cases were considered in this work, the first one during unoccupied period at night time (without external load) and the other at day period with external load of 800W/m2 according to solar heat gain calculations during summer season in Iraq. All results confirm the use of TermoDeck system for ventilation and cooling/heating purposes in arid and hot climate for its ease, simple and good comfort performance and to save energy and improve the overall energy performance of the building by reducing the peak load. Wahid S. MohammadTalib K. MurtadhaKarrar A. AhmedAl-Khwarizmi College of Engineering – University of BaghdadarticleChemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 10, Iss 3 (2014) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 Wahid S. Mohammad Talib K. Murtadha Karrar A. Ahmed Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions |
description |
In this paper, experimental study has been done for temperature distribution in space conditioned with Ventilation Hollow Core Slab (TermoDeck) system. The experiments were carried out on a model room with dimensions of (1m 1.2m 1m) that was built according to a suitable scale factor of (1/4). The temperature distributions was measured by 59 thermocouples fixed in several locations in the test room. Two cases were considered in this work, the first one during unoccupied period at night time (without external load) and the other at day period with external load of 800W/m2 according to solar heat gain calculations during summer season in Iraq. All results confirm the use of TermoDeck system for ventilation and cooling/heating purposes in arid and hot climate for its ease, simple and good comfort performance and to save energy and improve the overall energy performance of the building by reducing the peak load.
|
format |
article |
author |
Wahid S. Mohammad Talib K. Murtadha Karrar A. Ahmed |
author_facet |
Wahid S. Mohammad Talib K. Murtadha Karrar A. Ahmed |
author_sort |
Wahid S. Mohammad |
title |
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions |
title_short |
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions |
title_full |
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions |
title_fullStr |
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions |
title_full_unstemmed |
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions |
title_sort |
using termodeck system for pre-cooling/ heating to control the building inside conditions |
publisher |
Al-Khwarizmi College of Engineering – University of Baghdad |
publishDate |
2014 |
url |
https://doaj.org/article/ae02c6b16d4e4c1cabaea8b684b70b3d |
work_keys_str_mv |
AT wahidsmohammad usingtermodecksystemforprecoolingheatingtocontrolthebuildinginsideconditions AT talibkmurtadha usingtermodecksystemforprecoolingheatingtocontrolthebuildinginsideconditions AT karraraahmed usingtermodecksystemforprecoolingheatingtocontrolthebuildinginsideconditions |
_version_ |
1718401392259891200 |