Experimental dependences of measurement data on the volume of inhaled air in multi-frequency electrical impedance tomography

This paper proposes an approach to modeling the process of artificial ventilation of human lungs by their controlled filling with a fixed volume of air, using an incentive spirometer Coach 2. This makes it possible to simulate the ventilation process for a healthy person and to link the assigned res...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Grayr Aleksanyan
Formato: article
Lenguaje:EN
RU
UK
Publicado: PC Technology Center 2021
Materias:
Acceso en línea:https://doaj.org/article/ae7d0905eba745669ad9aa042baf260d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ae7d0905eba745669ad9aa042baf260d
record_format dspace
spelling oai:doaj.org-article:ae7d0905eba745669ad9aa042baf260d2021-11-08T08:04:06ZExperimental dependences of measurement data on the volume of inhaled air in multi-frequency electrical impedance tomography1729-37741729-406110.15587/1729-4061.2021.241769https://doaj.org/article/ae7d0905eba745669ad9aa042baf260d2021-10-01T00:00:00Zhttp://journals.uran.ua/eejet/article/view/241769https://doaj.org/toc/1729-3774https://doaj.org/toc/1729-4061This paper proposes an approach to modeling the process of artificial ventilation of human lungs by their controlled filling with a fixed volume of air, using an incentive spirometer Coach 2. This makes it possible to simulate the ventilation process for a healthy person and to link the assigned respiratory volume to measurement data. The results of experimental studies of the developed system of multifrequency electric impedance tomography are presented. The tests were performed for the frequency range from 50 kHz to 400 kHz (with a pitch of 50 kHz) at assigned respiratory volumes from 500 ml to 4,000 ml (with a pitch of 500 ml) for five inhalation/exhalation cycles. The scheme of research: active inhalation ‒ passive exhalation, the number of tested volunteers ‒ 3 people from the developers of the system. As a result, the dependences of the measured values of changes in potentials on the frequency of injected current for different respiratory volumes in three test participants without pathologies of the respiratory function and the external respiration function were obtained. The obtained results of the experimental studies show that there is a dependence of the value of the measurement data both on the volume of inhaled air and on the frequency of the injected current. This feature can be used to develop a number of medical devices for personalized monitoring of human lung function. It was also revealed that there are frequencies at which the maximum spread of measurement data according to the results of a series of repeated experiments is observed. At the same time, the nature of the change in the measurement data of the EIT at an increase in the volume of inhaled air is the same for all test participants. It is assumed that this feature can also be used to increase the EIT personalization degreeGrayr AleksanyanPC Technology Centerarticleelectric impedance tomographymultifrequencymeasurement datarespiratory volumesexperimental studiesconductivityTechnology (General)T1-995IndustryHD2321-4730.9ENRUUKEastern-European Journal of Enterprise Technologies, Vol 5, Iss 5 (113), Pp 39-50 (2021)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic electric impedance tomography
multifrequency
measurement data
respiratory volumes
experimental studies
conductivity
Technology (General)
T1-995
Industry
HD2321-4730.9
spellingShingle electric impedance tomography
multifrequency
measurement data
respiratory volumes
experimental studies
conductivity
Technology (General)
T1-995
Industry
HD2321-4730.9
Grayr Aleksanyan
Experimental dependences of measurement data on the volume of inhaled air in multi-frequency electrical impedance tomography
description This paper proposes an approach to modeling the process of artificial ventilation of human lungs by their controlled filling with a fixed volume of air, using an incentive spirometer Coach 2. This makes it possible to simulate the ventilation process for a healthy person and to link the assigned respiratory volume to measurement data. The results of experimental studies of the developed system of multifrequency electric impedance tomography are presented. The tests were performed for the frequency range from 50 kHz to 400 kHz (with a pitch of 50 kHz) at assigned respiratory volumes from 500 ml to 4,000 ml (with a pitch of 500 ml) for five inhalation/exhalation cycles. The scheme of research: active inhalation ‒ passive exhalation, the number of tested volunteers ‒ 3 people from the developers of the system. As a result, the dependences of the measured values of changes in potentials on the frequency of injected current for different respiratory volumes in three test participants without pathologies of the respiratory function and the external respiration function were obtained. The obtained results of the experimental studies show that there is a dependence of the value of the measurement data both on the volume of inhaled air and on the frequency of the injected current. This feature can be used to develop a number of medical devices for personalized monitoring of human lung function. It was also revealed that there are frequencies at which the maximum spread of measurement data according to the results of a series of repeated experiments is observed. At the same time, the nature of the change in the measurement data of the EIT at an increase in the volume of inhaled air is the same for all test participants. It is assumed that this feature can also be used to increase the EIT personalization degree
format article
author Grayr Aleksanyan
author_facet Grayr Aleksanyan
author_sort Grayr Aleksanyan
title Experimental dependences of measurement data on the volume of inhaled air in multi-frequency electrical impedance tomography
title_short Experimental dependences of measurement data on the volume of inhaled air in multi-frequency electrical impedance tomography
title_full Experimental dependences of measurement data on the volume of inhaled air in multi-frequency electrical impedance tomography
title_fullStr Experimental dependences of measurement data on the volume of inhaled air in multi-frequency electrical impedance tomography
title_full_unstemmed Experimental dependences of measurement data on the volume of inhaled air in multi-frequency electrical impedance tomography
title_sort experimental dependences of measurement data on the volume of inhaled air in multi-frequency electrical impedance tomography
publisher PC Technology Center
publishDate 2021
url https://doaj.org/article/ae7d0905eba745669ad9aa042baf260d
work_keys_str_mv AT grayraleksanyan experimentaldependencesofmeasurementdataonthevolumeofinhaledairinmultifrequencyelectricalimpedancetomography
_version_ 1718442842757529600