Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review

The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and bioengineering applications. The reliability of the sEMG measurement strongly relies on the characteristics of the detection sys...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Andrea Merlo, Maria Chiara Bò, Isabella Campanini
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/af044f640d544d60b797a310b86c4ddf
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:af044f640d544d60b797a310b86c4ddf
record_format dspace
spelling oai:doaj.org-article:af044f640d544d60b797a310b86c4ddf2021-11-11T19:16:11ZElectrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review10.3390/s212173221424-8220https://doaj.org/article/af044f640d544d60b797a310b86c4ddf2021-11-01T00:00:00Zhttps://www.mdpi.com/1424-8220/21/21/7322https://doaj.org/toc/1424-8220The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and bioengineering applications. The reliability of the sEMG measurement strongly relies on the characteristics of the detection system used, because of possible crosstalk from the surrounding forearm muscles. We conducted a scoping review of the main databases to explore available guidelines of electrode placement on BRD and to map the electrode configurations used and authors’ awareness on the issues of crosstalk. One hundred and thirty-four studies were included in the review. The crosstalk was mentioned in 29 studies, although two studies only were specifically designed to assess it. One hundred and six studies (79%) did not even address the issue by generically placing the sensors above BRD, usually choosing large disposable ECG electrodes. The analysis of the literature highlights a general lack of awareness on the issues of crosstalk and the need for adequate training in the sEMG field. Three guidelines were found, whose recommendations have been compared and summarized to promote reliability in further studies. In particular, it is crucial to use miniaturized electrodes placed on a specific area over the muscle, especially when BRD activity is recorded for clinical applications.Andrea MerloMaria Chiara BòIsabella CampaniniMDPI AGarticlebrachioradialissurface electromyographyelectrode placementcrosstalkupper limbChemical technologyTP1-1185ENSensors, Vol 21, Iss 7322, p 7322 (2021)
institution DOAJ
collection DOAJ
language EN
topic brachioradialis
surface electromyography
electrode placement
crosstalk
upper limb
Chemical technology
TP1-1185
spellingShingle brachioradialis
surface electromyography
electrode placement
crosstalk
upper limb
Chemical technology
TP1-1185
Andrea Merlo
Maria Chiara Bò
Isabella Campanini
Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review
description The brachioradialis muscle (BRD) is one of the main elbow flexors and is often assessed by surface electromyography (sEMG) in physiology, clinical, sports, ergonomics, and bioengineering applications. The reliability of the sEMG measurement strongly relies on the characteristics of the detection system used, because of possible crosstalk from the surrounding forearm muscles. We conducted a scoping review of the main databases to explore available guidelines of electrode placement on BRD and to map the electrode configurations used and authors’ awareness on the issues of crosstalk. One hundred and thirty-four studies were included in the review. The crosstalk was mentioned in 29 studies, although two studies only were specifically designed to assess it. One hundred and six studies (79%) did not even address the issue by generically placing the sensors above BRD, usually choosing large disposable ECG electrodes. The analysis of the literature highlights a general lack of awareness on the issues of crosstalk and the need for adequate training in the sEMG field. Three guidelines were found, whose recommendations have been compared and summarized to promote reliability in further studies. In particular, it is crucial to use miniaturized electrodes placed on a specific area over the muscle, especially when BRD activity is recorded for clinical applications.
format article
author Andrea Merlo
Maria Chiara Bò
Isabella Campanini
author_facet Andrea Merlo
Maria Chiara Bò
Isabella Campanini
author_sort Andrea Merlo
title Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review
title_short Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review
title_full Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review
title_fullStr Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review
title_full_unstemmed Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review
title_sort electrode size and placement for surface emg bipolar detection from the brachioradialis muscle: a scoping review
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/af044f640d544d60b797a310b86c4ddf
work_keys_str_mv AT andreamerlo electrodesizeandplacementforsurfaceemgbipolardetectionfromthebrachioradialismuscleascopingreview
AT mariachiarabo electrodesizeandplacementforsurfaceemgbipolardetectionfromthebrachioradialismuscleascopingreview
AT isabellacampanini electrodesizeandplacementforsurfaceemgbipolardetectionfromthebrachioradialismuscleascopingreview
_version_ 1718431604413562880