Evaluation of Using Strong Column-Weak Beam Requirements in Prequalified Welded Connections in Intermediate Steel Moment Frame

Beams are genarally used to face bendind force and columns are used to face axial load. as the seismic load comes parallely with respect to earth surface. so the column faces the load pependicularly which is very risky for the column. after that load gets distributed to all the beams. for this reaso...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mohammad Ali Kafi, payam tarighi
Formato: article
Lenguaje:FA
Publicado: Iranian Society of Structrual Engineering (ISSE) 2019
Materias:
Acceso en línea:https://doaj.org/article/afea50ba09f94a1395eefca30f56c529
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:afea50ba09f94a1395eefca30f56c529
record_format dspace
spelling oai:doaj.org-article:afea50ba09f94a1395eefca30f56c5292021-11-08T15:50:45ZEvaluation of Using Strong Column-Weak Beam Requirements in Prequalified Welded Connections in Intermediate Steel Moment Frame2476-39772538-261610.22065/jsce.2017.89781.1240https://doaj.org/article/afea50ba09f94a1395eefca30f56c5292019-02-01T00:00:00Zhttps://www.jsce.ir/article_51242_aed82af26bcb624716c49d19e9127884.pdfhttps://doaj.org/toc/2476-3977https://doaj.org/toc/2538-2616Beams are genarally used to face bendind force and columns are used to face axial load. as the seismic load comes parallely with respect to earth surface. so the column faces the load pependicularly which is very risky for the column. after that load gets distributed to all the beams. for this reason columns must be strong to make the structure more earth quake resistant.Generally column failure is reason of soft story and collapse of structure Also, because of the axial load yield of columns in shear and moment forces cause loss of strength more than beams and other elements. Structural design codes have a requirement for strength column and weak beam in all joints of special moment connection. In this research strength column and weak beam in prequalified moment connection like reduced beam section (RBS), cover plate connection (WFP) and the welded unreinforced flange-welded web (WUF-W) connection in intermediate moment frames studied. Results shown that ignore strung column and weak beam requirements effect function of the connection and cues to plastic hinge formed in a column. This is effect reduce energy abortion, stiffness and bearing capacity of connections. so as a result it was suggested that for better perfomance prequalified welded connections in intermediate steel moment frame controlled strong columns weak beams requirements.Mohammad Ali Kafipayam tarighiIranian Society of Structrual Engineering (ISSE)articlesoft storystrong column-weak beamintermediate ductilitymoment connectionenergy abortionstiffnessbearing capacityBridge engineeringTG1-470Building constructionTH1-9745FAJournal of Structural and Construction Engineering, Vol 5, Iss 4, Pp 195-206 (2019)
institution DOAJ
collection DOAJ
language FA
topic soft story
strong column-weak beam
intermediate ductility
moment connection
energy abortion
stiffness
bearing capacity
Bridge engineering
TG1-470
Building construction
TH1-9745
spellingShingle soft story
strong column-weak beam
intermediate ductility
moment connection
energy abortion
stiffness
bearing capacity
Bridge engineering
TG1-470
Building construction
TH1-9745
Mohammad Ali Kafi
payam tarighi
Evaluation of Using Strong Column-Weak Beam Requirements in Prequalified Welded Connections in Intermediate Steel Moment Frame
description Beams are genarally used to face bendind force and columns are used to face axial load. as the seismic load comes parallely with respect to earth surface. so the column faces the load pependicularly which is very risky for the column. after that load gets distributed to all the beams. for this reason columns must be strong to make the structure more earth quake resistant.Generally column failure is reason of soft story and collapse of structure Also, because of the axial load yield of columns in shear and moment forces cause loss of strength more than beams and other elements. Structural design codes have a requirement for strength column and weak beam in all joints of special moment connection. In this research strength column and weak beam in prequalified moment connection like reduced beam section (RBS), cover plate connection (WFP) and the welded unreinforced flange-welded web (WUF-W) connection in intermediate moment frames studied. Results shown that ignore strung column and weak beam requirements effect function of the connection and cues to plastic hinge formed in a column. This is effect reduce energy abortion, stiffness and bearing capacity of connections. so as a result it was suggested that for better perfomance prequalified welded connections in intermediate steel moment frame controlled strong columns weak beams requirements.
format article
author Mohammad Ali Kafi
payam tarighi
author_facet Mohammad Ali Kafi
payam tarighi
author_sort Mohammad Ali Kafi
title Evaluation of Using Strong Column-Weak Beam Requirements in Prequalified Welded Connections in Intermediate Steel Moment Frame
title_short Evaluation of Using Strong Column-Weak Beam Requirements in Prequalified Welded Connections in Intermediate Steel Moment Frame
title_full Evaluation of Using Strong Column-Weak Beam Requirements in Prequalified Welded Connections in Intermediate Steel Moment Frame
title_fullStr Evaluation of Using Strong Column-Weak Beam Requirements in Prequalified Welded Connections in Intermediate Steel Moment Frame
title_full_unstemmed Evaluation of Using Strong Column-Weak Beam Requirements in Prequalified Welded Connections in Intermediate Steel Moment Frame
title_sort evaluation of using strong column-weak beam requirements in prequalified welded connections in intermediate steel moment frame
publisher Iranian Society of Structrual Engineering (ISSE)
publishDate 2019
url https://doaj.org/article/afea50ba09f94a1395eefca30f56c529
work_keys_str_mv AT mohammadalikafi evaluationofusingstrongcolumnweakbeamrequirementsinprequalifiedweldedconnectionsinintermediatesteelmomentframe
AT payamtarighi evaluationofusingstrongcolumnweakbeamrequirementsinprequalifiedweldedconnectionsinintermediatesteelmomentframe
_version_ 1718441694837342208