Technical and radiological image quality comparison of different liquid crystal displays for radiology
Francina EM Dams,2 KY Esther Leung,1 Pieter HM van der Valk,2 Marc CJM Kock,2 Jeroen Bosman,1 Sjoerd P Niehof1 1Medical Physics and Technology, 2Department of Radiology, Albert Schweitzer Hospital, Dordrecht, The Netherlands Background: To inform cost-effective decisions in purchasing new medical...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2014
|
Materias: | |
Acceso en línea: | https://doaj.org/article/b043fce77a5143a68cf0d27f94887a0c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:b043fce77a5143a68cf0d27f94887a0c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:b043fce77a5143a68cf0d27f94887a0c2021-12-02T03:47:50ZTechnical and radiological image quality comparison of different liquid crystal displays for radiology1179-1470https://doaj.org/article/b043fce77a5143a68cf0d27f94887a0c2014-10-01T00:00:00Zhttp://www.dovepress.com/technical-and-radiological-image-quality-comparison-of-different-liqui-peer-reviewed-article-MDERhttps://doaj.org/toc/1179-1470 Francina EM Dams,2 KY Esther Leung,1 Pieter HM van der Valk,2 Marc CJM Kock,2 Jeroen Bosman,1 Sjoerd P Niehof1 1Medical Physics and Technology, 2Department of Radiology, Albert Schweitzer Hospital, Dordrecht, The Netherlands Background: To inform cost-effective decisions in purchasing new medical liquid crystal displays, we compared the image quality in displays made by three manufacturers. Methods: We recruited 19 radiologists and residents to compare the image quality of four liquid crystal displays, including 3-megapixel Barco®, Eizo®, and NEC® displays and a 6-megapixel Barco display. The evaluators were blinded to the manufacturers' names. Technical assessments were based on acceptance criteria and test patterns proposed by the American Association of Physicists in Medicine. Radiological assessments were performed on images from the American Association of Physicists in Medicine Task Group 18. They included X-ray images of the thorax, knee, and breast, a computed tomographic image of the thorax, and a magnetic resonance image of the brain. Image quality was scored on an analog scale (range 0–10). Statistical analysis was performed with repeated-measures analysis of variance. Results: The Barco 3-megapixel display passed all acceptance criteria. The Eizo and NEC displays passed the acceptance criteria, except for the darkest pixel value in the grayscale display function. The Barco 6-megapixel display failed criteria for the maximum luminance response and the veiling glare. Mean radiological assessment scores were 7.8±1.1 (Barco 3-megapixel), 7.8±1.2 (Eizo), 8.1±1.0 (NEC), and 8.1±1.0 (Barco 6-megapixel). No significant differences were found between displays. Conclusion: According to the tested criteria, all the displays had comparable image quality; however, there was a three-fold difference in price between the most and least expensive displays. Keywords: data display, humans, radiographic image enhancement, user-computer interface, liquid crystalsDams FELeung KYvan der Valk PHKock MCBosman JNiehof SPDove Medical PressarticleMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol 2014, Iss default, Pp 371-377 (2014) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medical technology R855-855.5 |
spellingShingle |
Medical technology R855-855.5 Dams FE Leung KY van der Valk PH Kock MC Bosman J Niehof SP Technical and radiological image quality comparison of different liquid crystal displays for radiology |
description |
Francina EM Dams,2 KY Esther Leung,1 Pieter HM van der Valk,2 Marc CJM Kock,2 Jeroen Bosman,1 Sjoerd P Niehof1 1Medical Physics and Technology, 2Department of Radiology, Albert Schweitzer Hospital, Dordrecht, The Netherlands Background: To inform cost-effective decisions in purchasing new medical liquid crystal displays, we compared the image quality in displays made by three manufacturers. Methods: We recruited 19 radiologists and residents to compare the image quality of four liquid crystal displays, including 3-megapixel Barco®, Eizo®, and NEC® displays and a 6-megapixel Barco display. The evaluators were blinded to the manufacturers' names. Technical assessments were based on acceptance criteria and test patterns proposed by the American Association of Physicists in Medicine. Radiological assessments were performed on images from the American Association of Physicists in Medicine Task Group 18. They included X-ray images of the thorax, knee, and breast, a computed tomographic image of the thorax, and a magnetic resonance image of the brain. Image quality was scored on an analog scale (range 0–10). Statistical analysis was performed with repeated-measures analysis of variance. Results: The Barco 3-megapixel display passed all acceptance criteria. The Eizo and NEC displays passed the acceptance criteria, except for the darkest pixel value in the grayscale display function. The Barco 6-megapixel display failed criteria for the maximum luminance response and the veiling glare. Mean radiological assessment scores were 7.8±1.1 (Barco 3-megapixel), 7.8±1.2 (Eizo), 8.1±1.0 (NEC), and 8.1±1.0 (Barco 6-megapixel). No significant differences were found between displays. Conclusion: According to the tested criteria, all the displays had comparable image quality; however, there was a three-fold difference in price between the most and least expensive displays. Keywords: data display, humans, radiographic image enhancement, user-computer interface, liquid crystals |
format |
article |
author |
Dams FE Leung KY van der Valk PH Kock MC Bosman J Niehof SP |
author_facet |
Dams FE Leung KY van der Valk PH Kock MC Bosman J Niehof SP |
author_sort |
Dams FE |
title |
Technical and radiological image quality comparison of different liquid crystal displays for radiology |
title_short |
Technical and radiological image quality comparison of different liquid crystal displays for radiology |
title_full |
Technical and radiological image quality comparison of different liquid crystal displays for radiology |
title_fullStr |
Technical and radiological image quality comparison of different liquid crystal displays for radiology |
title_full_unstemmed |
Technical and radiological image quality comparison of different liquid crystal displays for radiology |
title_sort |
technical and radiological image quality comparison of different liquid crystal displays for radiology |
publisher |
Dove Medical Press |
publishDate |
2014 |
url |
https://doaj.org/article/b043fce77a5143a68cf0d27f94887a0c |
work_keys_str_mv |
AT damsfe technicalandradiologicalimagequalitycomparisonofdifferentliquidcrystaldisplaysforradiology AT leungky technicalandradiologicalimagequalitycomparisonofdifferentliquidcrystaldisplaysforradiology AT vandervalkph technicalandradiologicalimagequalitycomparisonofdifferentliquidcrystaldisplaysforradiology AT kockmc technicalandradiologicalimagequalitycomparisonofdifferentliquidcrystaldisplaysforradiology AT bosmanj technicalandradiologicalimagequalitycomparisonofdifferentliquidcrystaldisplaysforradiology AT niehofsp technicalandradiologicalimagequalitycomparisonofdifferentliquidcrystaldisplaysforradiology |
_version_ |
1718401641964634112 |