Visual, aberrometric, photic phenomena, and patient satisfaction after myopic wavefront-guided LASIK using a high-resolution aberrometer

Sarah Moussa, Alois K Dexl, Eva M Krall, Eva M Arlt, Günther Grabner, Josef Ruckhofer Department of Ophthalmology, Paracelsus Medical University Salzburg, Salzburg, Austria Purpose: The purpose of this study was to evaluate the visual, refractive, and aberrometric outcomes as well as the...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Moussa S, Dexl AK, Krall EM, Arlt EM, Grabner G, Ruckhofer J
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://doaj.org/article/b083e12bd43e463eb35ec330e4db65fc
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Sarah Moussa, Alois K Dexl, Eva M Krall, Eva M Arlt, Günther Grabner, Josef Ruckhofer Department of Ophthalmology, Paracelsus Medical University Salzburg, Salzburg, Austria Purpose: The purpose of this study was to evaluate the visual, refractive, and aberrometric outcomes as well as the level of patient satisfaction and photic phenomena after myopic laser in situ keratomileusis (LASIK) surgery using wavefront-guided (WFG) ablations based on measurements obtained with a high-resolution aberrometer. Patients and methods: This study was a prospective analysis including 253 eyes of 127 patients (aged between 19 years and 54 years) undergoing WFG LASIK using the STAR S4 IR Excimer Laser System combined with the iDesign System and iFS Femtosecond Laser. Visual, refractive, and aberrometric outcomes during a 2-month follow-up as well as patient satisfaction and photic phenomena were evaluated by means of a questionnaire. Results: A total of 85% (215/253) and 99% (251/253) of eyes achieved a postoperative (Postop) uncorrected distance visual acuity of 20/16 and 20/20, respectively, and all eyes achieved an uncorrected distance visual acuity of 20/25. Postop spherical equivalent values were within ±0.25 D and ±0.50 D in 97% and 100% of eyes, respectively. Likewise, manifest cylinder was <0.25 D in 97% (245/253) of eyes. A statistically significant reduction was found in the total root mean square (P<0.001) and in the level of primary spherical aberration (P=0.001). Postop difficulties related to vision were graded as minimal, with low levels of photic phenomena and high levels of patient satisfaction. The level of difficulty to perform daily activities and the level of glare perceived by patients while driving car were significantly decreased (P<0.001). Conclusion: WFG LASIK surgery using the technology evaluated is predictable and effective for the correction of myopia and leads to high levels of patient satisfaction. Keywords: LASIK, patient satisfaction, Wave-front guided LASIK, high resolution aberrometer, photic phenomena, glare