A laminar flow unit for the care of critically ill newborn infants

Jose MR Perez,1 Sergio G Golombek,2 Carlos Fajardo,3 Augusto Sola41Stella Maris Hospital, International Neurodevelopment Neonatal Center (CINN), Sao Paulo, Brazil; 2M Fareri Children’s Hospital, Westchester Medical Center, New York Medical College, Valhalla, NY, USA; 3University of Calgary...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Perez JM, Golombek SG, Fajardo C, Sola A
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://doaj.org/article/b0f40cb590594d2da70476e22c283d81
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b0f40cb590594d2da70476e22c283d81
record_format dspace
spelling oai:doaj.org-article:b0f40cb590594d2da70476e22c283d812021-12-02T01:58:07ZA laminar flow unit for the care of critically ill newborn infants1179-1470https://doaj.org/article/b0f40cb590594d2da70476e22c283d812013-10-01T00:00:00Zhttp://www.dovepress.com/a-laminar-flow-unit-for-the-care-of-critically-ill-newborn-infants-a14710https://doaj.org/toc/1179-1470Jose MR Perez,1 Sergio G Golombek,2 Carlos Fajardo,3 Augusto Sola41Stella Maris Hospital, International Neurodevelopment Neonatal Center (CINN), Sao Paulo, Brazil; 2M Fareri Children’s Hospital, Westchester Medical Center, New York Medical College, Valhalla, NY, USA; 3University of Calgary, Calgary, Canada; 4St Jude Hospital, Fullerton, California, CA, USAIntroduction: Medical and nursing care of newborns is predicated on the delicate control and balance of several vital parameters. Closed incubators and open radiant warmers are the most widely used devices for the care of neonates in intensive care; however, several well-known limitations of these devises have not been resolved. The use of laminar flow is widely used in many fields of medicine, and may have applications in neonatal care.Objective: To describe the neonatal laminar flow unit, a new equipment we designed for care of ill newborns.Methods: The idea, design, and development of this device was completed in Sao Paulo, Brazil. The unit is an open mobile bed designed with the objective of maintaining the advantages of the incubator and radiant warmer, while overcoming some of their inherent shortcomings; these shortcomings include noise, magnetic fields and acrylic barriers in incubators, and lack of isolation and water loss through skin in radiant warmers. The unit has a pump that aspirates environmental air which is warmed by electrical resistance and decontaminated with High Efficiency Particulate Air Filter (HEPA) filters (laminar flow). The flow is directed by an air flow directioner. The unit has an embedded humidifier to increase humidity in the infant’s microenvironment and a servo control mechanism for regulation of skin temperature.Results: The laminar flow unit is open and facilitates access of care providers and family, which is not the case in incubators. It provides warming by convection at an air velocity of 0.45 m/s, much faster than an incubator (0.1 m/s). The system provides isolation 1000 class (less than 1,000 particles higher than 0.3 micron per cubic feet at all times). This is much more protection than an incubator provides and more than radiant warmers, which have no isolation whatsoever. Additionally, it provides humidification of the newborn’s microenvironment (about 60% relative humidity), which is impossible with a radiant warmer, which produces high water body loss. It has no mechanical barriers like acrylic walls, its magnetic field is lower than an incubator (0.25 µt versus 1.2 µt), and the noise is minimal compared to incubators. The unit is also able to provide controlled total body hypothermia, which is not possible with either of the other two units.Conclusion: The laminar flow unit for neonatal care is a novel device which we recently developed. The introduction of laminar flow technology represents a real innovation in the neonatal field. We have described the various components of the unit and the potential advantages for management of ill neonates. This will hopefully lead to improved clinical outcomes and more effective neonatal management and safety.Keywords: laminar flow, newborn intensive care, incubator, radiant warmerPerez JMGolombek SGFajardo CSola ADove Medical PressarticleMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol 2013, Iss default, Pp 163-167 (2013)
institution DOAJ
collection DOAJ
language EN
topic Medical technology
R855-855.5
spellingShingle Medical technology
R855-855.5
Perez JM
Golombek SG
Fajardo C
Sola A
A laminar flow unit for the care of critically ill newborn infants
description Jose MR Perez,1 Sergio G Golombek,2 Carlos Fajardo,3 Augusto Sola41Stella Maris Hospital, International Neurodevelopment Neonatal Center (CINN), Sao Paulo, Brazil; 2M Fareri Children’s Hospital, Westchester Medical Center, New York Medical College, Valhalla, NY, USA; 3University of Calgary, Calgary, Canada; 4St Jude Hospital, Fullerton, California, CA, USAIntroduction: Medical and nursing care of newborns is predicated on the delicate control and balance of several vital parameters. Closed incubators and open radiant warmers are the most widely used devices for the care of neonates in intensive care; however, several well-known limitations of these devises have not been resolved. The use of laminar flow is widely used in many fields of medicine, and may have applications in neonatal care.Objective: To describe the neonatal laminar flow unit, a new equipment we designed for care of ill newborns.Methods: The idea, design, and development of this device was completed in Sao Paulo, Brazil. The unit is an open mobile bed designed with the objective of maintaining the advantages of the incubator and radiant warmer, while overcoming some of their inherent shortcomings; these shortcomings include noise, magnetic fields and acrylic barriers in incubators, and lack of isolation and water loss through skin in radiant warmers. The unit has a pump that aspirates environmental air which is warmed by electrical resistance and decontaminated with High Efficiency Particulate Air Filter (HEPA) filters (laminar flow). The flow is directed by an air flow directioner. The unit has an embedded humidifier to increase humidity in the infant’s microenvironment and a servo control mechanism for regulation of skin temperature.Results: The laminar flow unit is open and facilitates access of care providers and family, which is not the case in incubators. It provides warming by convection at an air velocity of 0.45 m/s, much faster than an incubator (0.1 m/s). The system provides isolation 1000 class (less than 1,000 particles higher than 0.3 micron per cubic feet at all times). This is much more protection than an incubator provides and more than radiant warmers, which have no isolation whatsoever. Additionally, it provides humidification of the newborn’s microenvironment (about 60% relative humidity), which is impossible with a radiant warmer, which produces high water body loss. It has no mechanical barriers like acrylic walls, its magnetic field is lower than an incubator (0.25 µt versus 1.2 µt), and the noise is minimal compared to incubators. The unit is also able to provide controlled total body hypothermia, which is not possible with either of the other two units.Conclusion: The laminar flow unit for neonatal care is a novel device which we recently developed. The introduction of laminar flow technology represents a real innovation in the neonatal field. We have described the various components of the unit and the potential advantages for management of ill neonates. This will hopefully lead to improved clinical outcomes and more effective neonatal management and safety.Keywords: laminar flow, newborn intensive care, incubator, radiant warmer
format article
author Perez JM
Golombek SG
Fajardo C
Sola A
author_facet Perez JM
Golombek SG
Fajardo C
Sola A
author_sort Perez JM
title A laminar flow unit for the care of critically ill newborn infants
title_short A laminar flow unit for the care of critically ill newborn infants
title_full A laminar flow unit for the care of critically ill newborn infants
title_fullStr A laminar flow unit for the care of critically ill newborn infants
title_full_unstemmed A laminar flow unit for the care of critically ill newborn infants
title_sort laminar flow unit for the care of critically ill newborn infants
publisher Dove Medical Press
publishDate 2013
url https://doaj.org/article/b0f40cb590594d2da70476e22c283d81
work_keys_str_mv AT perezjm alaminarflowunitforthecareofcriticallyillnewborninfants
AT golombeksg alaminarflowunitforthecareofcriticallyillnewborninfants
AT fajardoc alaminarflowunitforthecareofcriticallyillnewborninfants
AT solaa alaminarflowunitforthecareofcriticallyillnewborninfants
AT perezjm laminarflowunitforthecareofcriticallyillnewborninfants
AT golombeksg laminarflowunitforthecareofcriticallyillnewborninfants
AT fajardoc laminarflowunitforthecareofcriticallyillnewborninfants
AT solaa laminarflowunitforthecareofcriticallyillnewborninfants
_version_ 1718402797323419648