Measuring HCC Tumor Size in MRI—The Sequence Matters!
Background: The aim of this paper was to assess and compare the accuracy of common magnetic resonance imaging (MRI) pulse sequences in measuring the lesion sizes of hepatocellular carcinomas (HCCs) with respect to the Milan criteria and histopathology as a standard of reference. Methods: We included...
Guardado en:
Autores principales: | , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/b1da7848677947b7a55ba978445648ff |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Sumario: | Background: The aim of this paper was to assess and compare the accuracy of common magnetic resonance imaging (MRI) pulse sequences in measuring the lesion sizes of hepatocellular carcinomas (HCCs) with respect to the Milan criteria and histopathology as a standard of reference. Methods: We included 45 patients with known HCC who underwent contrast-enhanced MRI of the liver prior to liver transplantation or tumor resection. Tumor size was assessed pathologically for all patients. The MRI protocol contained axial T2-weighted images as well as T1-weighted imaging sequences before and after application of Gd-EOB-DTPA. Tumor diameters, the sharpness of lesions, and the presence of artifacts were evaluated visually on all available MRI sequences. MRI measurements and pathologically assessed tumor dimensions were correlated using Pearson’s correlation coefficient and Bland–Altman plots. The rate of misclassifications following Milan criteria was assessed. Results: The mean absolute error (in cm) of MRI size measurements in comparison to pathology was the smallest for the hepatobiliary phase T1-weighted acquisition (0.71 ± 0.70 cm, r = 0.96) and largest for the T2w turbo-spin-echo (TSE) sequence (0.85 ± 0.78 cm, r = 0.94). The misclassification rate regarding tumor size under the Milan criteria was lowest for the T2w half-Fourier acquisition single-shot turbo spin-echo sequence and the hepatobiliary phase T1w acquisition (each 8.6%). The highest rate of misclassification occurred in the portal venous phase T1w acquisition and T2w TSE sequence (each 14.3%). Conclusions: The hepatobiliary phase T1-weighted acquisition seems to be most accurate among commonly used MRI sequences for measuring HCC tumor size, resulting in low rates of misclassification with respect to the Milan criteria. |
---|