Deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability
Keith Raymond Pine,1 Brian Sloan,2 KyuYeon Ivy Han,1 Simon Swift,3 Robert John Jacobs11Department of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; 2New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand;...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/b245c2df71c1477985ddb49ec63fa49d |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:b245c2df71c1477985ddb49ec63fa49d |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:b245c2df71c1477985ddb49ec63fa49d2021-12-02T06:10:30ZDeposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability1177-54671177-5483https://doaj.org/article/b245c2df71c1477985ddb49ec63fa49d2013-02-01T00:00:00Zhttp://www.dovepress.com/deposit-buildup-on-prosthetic-eye-material-in-vitro-and-its-effect-on--a12206https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Keith Raymond Pine,1 Brian Sloan,2 KyuYeon Ivy Han,1 Simon Swift,3 Robert John Jacobs11Department of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; 2New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; 3Department of Molecular Medicine and Pathology, School of Medical Sciences, The University of Auckland, Auckland, New ZealandBackground: The aim of this in-vitro study was to investigate the effect of different polishing standards on prosthetic eye material (poly(methyl methacrylate) [PMMA]) on surface wettability and the rate of protein and lipid buildup.Methods: Sample disks (12 mm diameter × 1 mm thickness) of PMMA were polished to three different standards of surface finish: low, normal, and optical quality contact lens standard. The sample disks were incubated in a protein-rich artificial tear solution (ATS) for the following periods of time: 1 second, 30 minutes, 1 hour, 4 hours, 24 hours, and 14 days. Surface wettability was measured with a goniometer before and after protein deposits were removed. One-way analysis of variance and paired-samples t-test were used for the statistical analysis.Results: Between 13.64 and 62.88 µg of protein adhered to the sample disks immediately upon immersion in ATS. Sample disks with the highest polish attracted less protein deposits. The sample disks polished to optical quality contact lens standard were more wettable than those less highly polished, and wettability significantly decreased following removal of protein deposits. The addition of lipids to protein-only ATS made no difference to the amount of protein deposited on the sample disks for any of the standards of surface polish tested.Conclusion: The findings are consistent with the results of the in-vivo investigation reported previously by the authors. Our view that the minimum standard of polish for prosthetic eyes should be optical quality contact lens standard and that deposits on PMMA prosthetic eyes improve the lubricating properties of the socket fluids has been reinforced by the results of this study.Keywords: protein deposits, surface polish, PMMAPine KRSloan BHan KYISwift SJacobs RJDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2013, Iss default, Pp 313-319 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Pine KR Sloan B Han KYI Swift S Jacobs RJ Deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability |
description |
Keith Raymond Pine,1 Brian Sloan,2 KyuYeon Ivy Han,1 Simon Swift,3 Robert John Jacobs11Department of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; 2New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; 3Department of Molecular Medicine and Pathology, School of Medical Sciences, The University of Auckland, Auckland, New ZealandBackground: The aim of this in-vitro study was to investigate the effect of different polishing standards on prosthetic eye material (poly(methyl methacrylate) [PMMA]) on surface wettability and the rate of protein and lipid buildup.Methods: Sample disks (12 mm diameter × 1 mm thickness) of PMMA were polished to three different standards of surface finish: low, normal, and optical quality contact lens standard. The sample disks were incubated in a protein-rich artificial tear solution (ATS) for the following periods of time: 1 second, 30 minutes, 1 hour, 4 hours, 24 hours, and 14 days. Surface wettability was measured with a goniometer before and after protein deposits were removed. One-way analysis of variance and paired-samples t-test were used for the statistical analysis.Results: Between 13.64 and 62.88 µg of protein adhered to the sample disks immediately upon immersion in ATS. Sample disks with the highest polish attracted less protein deposits. The sample disks polished to optical quality contact lens standard were more wettable than those less highly polished, and wettability significantly decreased following removal of protein deposits. The addition of lipids to protein-only ATS made no difference to the amount of protein deposited on the sample disks for any of the standards of surface polish tested.Conclusion: The findings are consistent with the results of the in-vivo investigation reported previously by the authors. Our view that the minimum standard of polish for prosthetic eyes should be optical quality contact lens standard and that deposits on PMMA prosthetic eyes improve the lubricating properties of the socket fluids has been reinforced by the results of this study.Keywords: protein deposits, surface polish, PMMA |
format |
article |
author |
Pine KR Sloan B Han KYI Swift S Jacobs RJ |
author_facet |
Pine KR Sloan B Han KYI Swift S Jacobs RJ |
author_sort |
Pine KR |
title |
Deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability |
title_short |
Deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability |
title_full |
Deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability |
title_fullStr |
Deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability |
title_full_unstemmed |
Deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability |
title_sort |
deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability |
publisher |
Dove Medical Press |
publishDate |
2013 |
url |
https://doaj.org/article/b245c2df71c1477985ddb49ec63fa49d |
work_keys_str_mv |
AT pinekr depositbuilduponprostheticeyematerialinvitroanditseffectonsurfacewettability AT sloanb depositbuilduponprostheticeyematerialinvitroanditseffectonsurfacewettability AT hankyi depositbuilduponprostheticeyematerialinvitroanditseffectonsurfacewettability AT swifts depositbuilduponprostheticeyematerialinvitroanditseffectonsurfacewettability AT jacobsrj depositbuilduponprostheticeyematerialinvitroanditseffectonsurfacewettability |
_version_ |
1718400070309642240 |