Improvement of Methodology for Assessing Fire-Protective Efficiency of Intumescent Coatings Applied on Metal Constructions

The article observes the possibility and feasibility of introducing new and improved methodology for assessing the performance of fire retardant intumescent coatings for steel structures. The results of a comparative assessment of coatings based on a set of parameters obtained in laboratory conditio...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ustinov Andrei, Babikova Anastasiia, Zybina Ol’ga, Lobov Denis, Printseva Marya, Klaptyuk Irina, Shkitronov Mikhail
Formato: article
Lenguaje:EN
FR
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/b282761c7e984d0fa7142b143285b146
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b282761c7e984d0fa7142b143285b146
record_format dspace
spelling oai:doaj.org-article:b282761c7e984d0fa7142b143285b1462021-11-12T11:44:23ZImprovement of Methodology for Assessing Fire-Protective Efficiency of Intumescent Coatings Applied on Metal Constructions2267-124210.1051/e3sconf/202132002009https://doaj.org/article/b282761c7e984d0fa7142b143285b1462021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/96/e3sconf_esei2021_02009.pdfhttps://doaj.org/toc/2267-1242The article observes the possibility and feasibility of introducing new and improved methodology for assessing the performance of fire retardant intumescent coatings for steel structures. The results of a comparative assessment of coatings based on a set of parameters obtained in laboratory conditions are presented: swelling coefficient, adhesion coefficient, adhesion of the coating system under high temperature conditions, kinetic parameters of thermolysis, thermal insulation. The smallscale laboratory test was developed to evaluate thermal insulating ability of 4 intumescent coatings applied to small steel plates. An improvement of the control method for assessing the fire retardant efficiency of intumescent coatings is proposed – instead of one test plate with dimensions of 600x600x5 mm with intumescent coating applied, a design of a metal frame-holder is proposed, in which 4 plates with dimensions of 300x300x5 mm can be fixed, and a set of thermocouples can be installed on each of them; all 4 plates are heated in the same conditions, thus the contradictions which may occur between the results of separate experiments are avoided. Such improvements made in the methodology of investigating the properties of intumescent coatings appeared to be fruitful, as correlation can be established between the laboratory tests and large-scale tests.Ustinov AndreiBabikova AnastasiiaZybina Ol’gaLobov DenisPrintseva MaryaKlaptyuk IrinaShkitronov MikhailEDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 320, p 02009 (2021)
institution DOAJ
collection DOAJ
language EN
FR
topic Environmental sciences
GE1-350
spellingShingle Environmental sciences
GE1-350
Ustinov Andrei
Babikova Anastasiia
Zybina Ol’ga
Lobov Denis
Printseva Marya
Klaptyuk Irina
Shkitronov Mikhail
Improvement of Methodology for Assessing Fire-Protective Efficiency of Intumescent Coatings Applied on Metal Constructions
description The article observes the possibility and feasibility of introducing new and improved methodology for assessing the performance of fire retardant intumescent coatings for steel structures. The results of a comparative assessment of coatings based on a set of parameters obtained in laboratory conditions are presented: swelling coefficient, adhesion coefficient, adhesion of the coating system under high temperature conditions, kinetic parameters of thermolysis, thermal insulation. The smallscale laboratory test was developed to evaluate thermal insulating ability of 4 intumescent coatings applied to small steel plates. An improvement of the control method for assessing the fire retardant efficiency of intumescent coatings is proposed – instead of one test plate with dimensions of 600x600x5 mm with intumescent coating applied, a design of a metal frame-holder is proposed, in which 4 plates with dimensions of 300x300x5 mm can be fixed, and a set of thermocouples can be installed on each of them; all 4 plates are heated in the same conditions, thus the contradictions which may occur between the results of separate experiments are avoided. Such improvements made in the methodology of investigating the properties of intumescent coatings appeared to be fruitful, as correlation can be established between the laboratory tests and large-scale tests.
format article
author Ustinov Andrei
Babikova Anastasiia
Zybina Ol’ga
Lobov Denis
Printseva Marya
Klaptyuk Irina
Shkitronov Mikhail
author_facet Ustinov Andrei
Babikova Anastasiia
Zybina Ol’ga
Lobov Denis
Printseva Marya
Klaptyuk Irina
Shkitronov Mikhail
author_sort Ustinov Andrei
title Improvement of Methodology for Assessing Fire-Protective Efficiency of Intumescent Coatings Applied on Metal Constructions
title_short Improvement of Methodology for Assessing Fire-Protective Efficiency of Intumescent Coatings Applied on Metal Constructions
title_full Improvement of Methodology for Assessing Fire-Protective Efficiency of Intumescent Coatings Applied on Metal Constructions
title_fullStr Improvement of Methodology for Assessing Fire-Protective Efficiency of Intumescent Coatings Applied on Metal Constructions
title_full_unstemmed Improvement of Methodology for Assessing Fire-Protective Efficiency of Intumescent Coatings Applied on Metal Constructions
title_sort improvement of methodology for assessing fire-protective efficiency of intumescent coatings applied on metal constructions
publisher EDP Sciences
publishDate 2021
url https://doaj.org/article/b282761c7e984d0fa7142b143285b146
work_keys_str_mv AT ustinovandrei improvementofmethodologyforassessingfireprotectiveefficiencyofintumescentcoatingsappliedonmetalconstructions
AT babikovaanastasiia improvementofmethodologyforassessingfireprotectiveefficiencyofintumescentcoatingsappliedonmetalconstructions
AT zybinaolga improvementofmethodologyforassessingfireprotectiveefficiencyofintumescentcoatingsappliedonmetalconstructions
AT lobovdenis improvementofmethodologyforassessingfireprotectiveefficiencyofintumescentcoatingsappliedonmetalconstructions
AT printsevamarya improvementofmethodologyforassessingfireprotectiveefficiencyofintumescentcoatingsappliedonmetalconstructions
AT klaptyukirina improvementofmethodologyforassessingfireprotectiveefficiencyofintumescentcoatingsappliedonmetalconstructions
AT shkitronovmikhail improvementofmethodologyforassessingfireprotectiveefficiencyofintumescentcoatingsappliedonmetalconstructions
_version_ 1718430573158989824