Automatic classification of water samples using an optimized SVM model applied to cyclic voltammetry signals.
Background: concern about the quality of the water for human consumption has become widespread among the population. The taste and some problems associated with drinking water have been the cause of increased demand for bottled water. Due to this, day to day, a large number of companies has manifes...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Universidad de Antioquia
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/b2a694fdd85f4a2bbde7922b0b2c2d3e |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Sumario: | Background: concern about the quality of the water for human consumption has become widespread among the population. The taste and some problems associated with drinking water have been the cause of increased demand for bottled water. Due to this, day to day, a large number of companies has manifested their interest in the production of bottled water. Objective: to evaluate a novel automatic classification model that differentiates bottled water from tap water. Methods: the voltammetric technique consisted of three electrode setup. The output current has been considered for data analysis. From the results of grid search, six pairs of values were pre-selected for the parameters of σ and C whose results were similar. High values of accuracy, specificity and sensitivity were achieved in test dataset. The final decision was made after performing an ANOVA test of 100 repetitions of 5-fold cross-validation, 3000 models were evaluated with the parameter combinations described above for the SVM. Results: the oxidation and reduction peaks of the water samples have been observed to be prominent. Absolute values of current (I) increased in the case of public water samples, possibly due to the largest concentration of chloride ions which have higher contributions to the conductivity. 5-fold cross-validation test mean specificity resulted in C parameters values greater than 0 and between 0 and 30; a σ value greater than 10 and between 0 and 15 were found for tap water and bottled water, respectively. The combination (σ = 10, C = 30) presented best results in accuracy 0.988 ± 0.037, specificity 0.973 ± 0.085 and sensitivity 1 ± 0.09. Conclusions: results of this research work have shown that voltammograms for values of current increased for tap water samples, 9.94e-6μA, compared to 7.99e-6μA due to higher chloride ions concentration in the former. The parameters combination (σ = 10, C = 20) was selected as optimal parameters since there were no significant difference between this and the former.
|
---|