Comparison of Apical Transportation with Using Hand, Reciprocal and Race Instrumentation

BACKGROUND AND OBJECTIVE: Mechanical preparation of root canal system is an important objective of root canal therapy. Many rotary devices have been produced to decrease instrumentation time and improve its quality.The purpose of this study was to compare apical transportation in root canal treatmen...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Disfani R, Moradi S, Afkhami Jedi F
Formato: article
Lenguaje:EN
FA
Publicado: Babol University of Medical Sciences 2011
Materias:
R
Acceso en línea:https://doaj.org/article/b2dc0970f40940ed885f0a78714cbe9f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b2dc0970f40940ed885f0a78714cbe9f
record_format dspace
spelling oai:doaj.org-article:b2dc0970f40940ed885f0a78714cbe9f2021-11-10T08:56:48ZComparison of Apical Transportation with Using Hand, Reciprocal and Race Instrumentation1561-41072251-7170https://doaj.org/article/b2dc0970f40940ed885f0a78714cbe9f2011-09-01T00:00:00Zhttp://jbums.org/article-1-3870-en.htmlhttps://doaj.org/toc/1561-4107https://doaj.org/toc/2251-7170BACKGROUND AND OBJECTIVE: Mechanical preparation of root canal system is an important objective of root canal therapy. Many rotary devices have been produced to decrease instrumentation time and improve its quality.The purpose of this study was to compare apical transportation in root canal treatment with three methods of hand, reciprocal and rotary (Race) instrumentation.METHODS: In this experimental study 45 extracted human mandibular first molar were selected. The crown was cut at CEJ. The roots were mounted in acrylic resin material. The roots had a 20-40 degree canal curvature. Teeth were randomly divided into 3 groups. Group one was prepared with hand method and NiTi files, group two was prepared with Endogripper handpiece and NiTi files, group three was prepared with Race rotary system. By superimposing the initial file and MAF radiography the apical transportation was evaluated (double exposure radiography method). FINDINGS: Race rotary system (group 3) had prepared canals without transportation and deviation in the original shape of canals. NiTi hand files (group 1) had prepared canals with 8 apical transportations out of 15 root canals. Reciprocal handpiece with NiTi files had prepared canals with 7 apical transportations. Race rotary system was prepared canals with significant the least apical transportations than other groups (p<0.05).CONCLUSION: The results showed that original canal shape in apical region had minimum transportation with race rotary system compare with hand or reciprocal preparation.Disfani R, Moradi S, Afkhami Jedi FBabol University of Medical Sciencesarticletransportationroot canal preparationnickel titanium filereciprocalMedicineRMedicine (General)R5-920ENFAMajallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul, Vol 13, Iss 5, Pp 29-33 (2011)
institution DOAJ
collection DOAJ
language EN
FA
topic transportation
root canal preparation
nickel titanium file
reciprocal
Medicine
R
Medicine (General)
R5-920
spellingShingle transportation
root canal preparation
nickel titanium file
reciprocal
Medicine
R
Medicine (General)
R5-920
Disfani R, Moradi S, Afkhami Jedi F
Comparison of Apical Transportation with Using Hand, Reciprocal and Race Instrumentation
description BACKGROUND AND OBJECTIVE: Mechanical preparation of root canal system is an important objective of root canal therapy. Many rotary devices have been produced to decrease instrumentation time and improve its quality.The purpose of this study was to compare apical transportation in root canal treatment with three methods of hand, reciprocal and rotary (Race) instrumentation.METHODS: In this experimental study 45 extracted human mandibular first molar were selected. The crown was cut at CEJ. The roots were mounted in acrylic resin material. The roots had a 20-40 degree canal curvature. Teeth were randomly divided into 3 groups. Group one was prepared with hand method and NiTi files, group two was prepared with Endogripper handpiece and NiTi files, group three was prepared with Race rotary system. By superimposing the initial file and MAF radiography the apical transportation was evaluated (double exposure radiography method). FINDINGS: Race rotary system (group 3) had prepared canals without transportation and deviation in the original shape of canals. NiTi hand files (group 1) had prepared canals with 8 apical transportations out of 15 root canals. Reciprocal handpiece with NiTi files had prepared canals with 7 apical transportations. Race rotary system was prepared canals with significant the least apical transportations than other groups (p<0.05).CONCLUSION: The results showed that original canal shape in apical region had minimum transportation with race rotary system compare with hand or reciprocal preparation.
format article
author Disfani R, Moradi S, Afkhami Jedi F
author_facet Disfani R, Moradi S, Afkhami Jedi F
author_sort Disfani R, Moradi S, Afkhami Jedi F
title Comparison of Apical Transportation with Using Hand, Reciprocal and Race Instrumentation
title_short Comparison of Apical Transportation with Using Hand, Reciprocal and Race Instrumentation
title_full Comparison of Apical Transportation with Using Hand, Reciprocal and Race Instrumentation
title_fullStr Comparison of Apical Transportation with Using Hand, Reciprocal and Race Instrumentation
title_full_unstemmed Comparison of Apical Transportation with Using Hand, Reciprocal and Race Instrumentation
title_sort comparison of apical transportation with using hand, reciprocal and race instrumentation
publisher Babol University of Medical Sciences
publishDate 2011
url https://doaj.org/article/b2dc0970f40940ed885f0a78714cbe9f
work_keys_str_mv AT disfanirmoradisafkhamijedif comparisonofapicaltransportationwithusinghandreciprocalandraceinstrumentation
_version_ 1718440321978728448