Pulsative flushing as a strategy to prevent bacterial colonization of vascular access devices

Agnès Ferroni,1 Florian Gaudin,1 Gérard Guiffant,2 Patrice Flaud,2 Jean-Jacques Durussel,2 Philippe Descamps,1 Patrick Berche,1 Xavier Nassif,1 Jacques Merckx2 1Assistance Publique-Hôpitaux de Paris, Laboratory of Microbiology, University Teaching Hospital Necker-Enf...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ferroni A, Gaudin F, Guiffant G, Flaud P, Durussel JJ, Descamps P, Berche P, Nassif X, Merckx J
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://doaj.org/article/b37f6ec34c3245c59eaf8a059d945380
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Agnès Ferroni,1 Florian Gaudin,1 Gérard Guiffant,2 Patrice Flaud,2 Jean-Jacques Durussel,2 Philippe Descamps,1 Patrick Berche,1 Xavier Nassif,1 Jacques Merckx2 1Assistance Publique-Hôpitaux de Paris, Laboratory of Microbiology, University Teaching Hospital Necker-Enfants Malades, 2University Paris-Diderot, MSC-UMR, CNRS 7057, Paris, France Abstract: Central venous device infections are associated with increased physical and psychological morbidity, mortality, length of stay, and costs. The aim of this study was to prove the efficacy of pulsatile flushing to prevent the bacterial colonization of vascular access devices. One hundred and forty four tests using 576 polyurethane short venous access catheters were performed. Four catheters per test were polluted with a fibronectin-serum albumin solution. Three were filled with a Staphylococcus aureus broth; one served as negative control. One contaminated catheter was not flushed (positive control), and two were flushed (10 mL.sec-1) with normal saline solution, either by ten successive boluses of 1 mL each or by one bolus of 10 mL. Each catheter was cultivated. The S. aureus quantity observed after continuous flushing was significantly higher than that observed after pulsative flushing (P<0.001). Unflushed catheters were 20.71 and 6.42 times more polluted than catheters flushed with the pulsative method or the continuous method, respectively. Pulsative flushing was at least twice as effective as continuous flushing in reducing the S. aureus count. Pulsative flushing is more effective than continuous flushing in reducing the endoluminal contamination. Pulsative flushing is a simple, effective, and inexpensive technique to reduce catheter bacterial colonization.Keywords: peripheral or central venous devices, hydrodynamics, bacterial colonization prevention, pulsative flushing