APPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD

Purpose. To analyze the transient processes in the discharge circuit of reservoir capacitor of electric discharge installations at a change in the circuit configuration during the discharge as well as to determine the appropriate circuit parameters for which the discharge process described by the th...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: N. I. Suprunovska, M. A. Shcherba
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2018
Materias:
Acceso en línea:https://doaj.org/article/b4555fda19184496811f70267f93ecf8
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b4555fda19184496811f70267f93ecf8
record_format dspace
spelling oai:doaj.org-article:b4555fda19184496811f70267f93ecf82021-12-02T18:18:16ZAPPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD10.20998/2074-272X.2018.6.062074-272X2309-3404https://doaj.org/article/b4555fda19184496811f70267f93ecf82018-12-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2018.6.06/149834https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. To analyze the transient processes in the discharge circuit of reservoir capacitor of electric discharge installations at a change in the circuit configuration during the discharge as well as to determine the appropriate circuit parameters for which the discharge process described by the third-order differential equation remains a damped oscillatory process. Methodology. We have applied the concepts of theoretical electrical engineering, the principles of theory of electrical circuits, theory of automatic control systems and mathematical simulation in the software package MathCAD 12. Results. We have obtained the analytical expressions and graphical dependencies that allow us to determine a relationship between the value of the element parameters of the discharge circuit of installations with an additional active-inductive chain and the character of the transient discharge process without solving a third-order differential equation. Originality. Using Vyshnegradsky's criteria and their graphical representations in the form of diagrams, we have proposed the procedure for determining the inductance value in additional chain shunting the capacitor of electric discharge installation in order to avoid the undesirable aperiodic discharge transient process in the stochastic load. Practical value. The use of this approach makes it possible to determine the ranges of the expedient change in the additional inductance at different load resistances for the realization of transient process required by the technology – the oscillatory discharge of the reservoir capacitor trough the load. N. I. SuprunovskaM. A. ShcherbaNational Technical University "Kharkiv Polytechnic Institute"articleelectric discharge installationcapacitor dischargetransientsVyshnegradsky's diagramstochastic loadElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 6, Pp 47-50 (2018)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic electric discharge installation
capacitor discharge
transients
Vyshnegradsky's diagram
stochastic load
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle electric discharge installation
capacitor discharge
transients
Vyshnegradsky's diagram
stochastic load
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
N. I. Suprunovska
M. A. Shcherba
APPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD
description Purpose. To analyze the transient processes in the discharge circuit of reservoir capacitor of electric discharge installations at a change in the circuit configuration during the discharge as well as to determine the appropriate circuit parameters for which the discharge process described by the third-order differential equation remains a damped oscillatory process. Methodology. We have applied the concepts of theoretical electrical engineering, the principles of theory of electrical circuits, theory of automatic control systems and mathematical simulation in the software package MathCAD 12. Results. We have obtained the analytical expressions and graphical dependencies that allow us to determine a relationship between the value of the element parameters of the discharge circuit of installations with an additional active-inductive chain and the character of the transient discharge process without solving a third-order differential equation. Originality. Using Vyshnegradsky's criteria and their graphical representations in the form of diagrams, we have proposed the procedure for determining the inductance value in additional chain shunting the capacitor of electric discharge installation in order to avoid the undesirable aperiodic discharge transient process in the stochastic load. Practical value. The use of this approach makes it possible to determine the ranges of the expedient change in the additional inductance at different load resistances for the realization of transient process required by the technology – the oscillatory discharge of the reservoir capacitor trough the load.
format article
author N. I. Suprunovska
M. A. Shcherba
author_facet N. I. Suprunovska
M. A. Shcherba
author_sort N. I. Suprunovska
title APPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD
title_short APPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD
title_full APPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD
title_fullStr APPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD
title_full_unstemmed APPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD
title_sort application of vyshnegradky's diagrams for transient analysis in electric discharge installations with stochastic load
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2018
url https://doaj.org/article/b4555fda19184496811f70267f93ecf8
work_keys_str_mv AT nisuprunovska applicationofvyshnegradkysdiagramsfortransientanalysisinelectricdischargeinstallationswithstochasticload
AT mashcherba applicationofvyshnegradkysdiagramsfortransientanalysisinelectricdischargeinstallationswithstochasticload
_version_ 1718378294360932352