Effect of Lidocaine Gel in Pain Relieving after Episiotomy

BACKGROUND AND OBJECTIVE: Perineal pain due to episiotomy is a stressful problem for women and in the first day of postpartum has more severity. The aim of this study was to investigate the efficacy of lidocaine gel 2% in relieving pain after a vaginal delivery with an episiotomy.METHODS: In a rando...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: M Abedzadeh, Z Sadat, F Saberi
Formato: article
Lenguaje:EN
FA
Publicado: Babol University of Medical Sciences 2009
Materias:
R
Acceso en línea:https://doaj.org/article/b58fd478335d4f54be2ea111c541a45a
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b58fd478335d4f54be2ea111c541a45a
record_format dspace
spelling oai:doaj.org-article:b58fd478335d4f54be2ea111c541a45a2021-11-10T09:02:43ZEffect of Lidocaine Gel in Pain Relieving after Episiotomy1561-41072251-7170https://doaj.org/article/b58fd478335d4f54be2ea111c541a45a2009-06-01T00:00:00Zhttp://jbums.org/article-1-3127-en.htmlhttps://doaj.org/toc/1561-4107https://doaj.org/toc/2251-7170BACKGROUND AND OBJECTIVE: Perineal pain due to episiotomy is a stressful problem for women and in the first day of postpartum has more severity. The aim of this study was to investigate the efficacy of lidocaine gel 2% in relieving pain after a vaginal delivery with an episiotomy.METHODS: In a randomized, double-blind, placebo-controlled trial, 150 women who had episiotomy received lidocaine gel 2% (n=75) or a placebo (n=75). Two groups were matched for age, pregnancy age, parity, education, nationality, infant sex and weight, kind of episiotomy, consumption of pethidine in labor, persons repair, consumption of analgesic in postpartum. After episiotomy we administered lidocaine gel and lubricant gel for women in experimental and control groups, respectively. Then pain ratings were recorded before the administration of the drugs and at 6 and 12 hr after the first dose, according to a numerical and verbal rating scale. Data were analyzed.FINDINGS: Average pain scores before using lidocaine gel in control group was 2.9±2 and in case group was 3.3±1.8. Twelve hours after using gel mean of pain score was 2.6 ± 2 in case group and 3.6 ± 2.4 in control group (p=0.009). Analgesia used in 6 subjects (8%) in case group and in 15 subjects (20%) in control group (p=0.034). There weren any adverse effect with lidocaine gel uses.CONCLUSION: This study suggested that lidocaine gel is a safe and effective method for episiotomy pain relief in first day of postpartum.M Abedzadeh,Z SadatF SaberiBabol University of Medical SciencesarticlelidocainepainepisiotomyMedicineRMedicine (General)R5-920ENFAMajallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul, Vol 11, Iss 2, Pp 43-48 (2009)
institution DOAJ
collection DOAJ
language EN
FA
topic lidocaine
pain
episiotomy
Medicine
R
Medicine (General)
R5-920
spellingShingle lidocaine
pain
episiotomy
Medicine
R
Medicine (General)
R5-920
M Abedzadeh,
Z Sadat
F Saberi
Effect of Lidocaine Gel in Pain Relieving after Episiotomy
description BACKGROUND AND OBJECTIVE: Perineal pain due to episiotomy is a stressful problem for women and in the first day of postpartum has more severity. The aim of this study was to investigate the efficacy of lidocaine gel 2% in relieving pain after a vaginal delivery with an episiotomy.METHODS: In a randomized, double-blind, placebo-controlled trial, 150 women who had episiotomy received lidocaine gel 2% (n=75) or a placebo (n=75). Two groups were matched for age, pregnancy age, parity, education, nationality, infant sex and weight, kind of episiotomy, consumption of pethidine in labor, persons repair, consumption of analgesic in postpartum. After episiotomy we administered lidocaine gel and lubricant gel for women in experimental and control groups, respectively. Then pain ratings were recorded before the administration of the drugs and at 6 and 12 hr after the first dose, according to a numerical and verbal rating scale. Data were analyzed.FINDINGS: Average pain scores before using lidocaine gel in control group was 2.9±2 and in case group was 3.3±1.8. Twelve hours after using gel mean of pain score was 2.6 ± 2 in case group and 3.6 ± 2.4 in control group (p=0.009). Analgesia used in 6 subjects (8%) in case group and in 15 subjects (20%) in control group (p=0.034). There weren any adverse effect with lidocaine gel uses.CONCLUSION: This study suggested that lidocaine gel is a safe and effective method for episiotomy pain relief in first day of postpartum.
format article
author M Abedzadeh,
Z Sadat
F Saberi
author_facet M Abedzadeh,
Z Sadat
F Saberi
author_sort M Abedzadeh,
title Effect of Lidocaine Gel in Pain Relieving after Episiotomy
title_short Effect of Lidocaine Gel in Pain Relieving after Episiotomy
title_full Effect of Lidocaine Gel in Pain Relieving after Episiotomy
title_fullStr Effect of Lidocaine Gel in Pain Relieving after Episiotomy
title_full_unstemmed Effect of Lidocaine Gel in Pain Relieving after Episiotomy
title_sort effect of lidocaine gel in pain relieving after episiotomy
publisher Babol University of Medical Sciences
publishDate 2009
url https://doaj.org/article/b58fd478335d4f54be2ea111c541a45a
work_keys_str_mv AT mabedzadeh effectoflidocainegelinpainrelievingafterepisiotomy
AT zsadat effectoflidocainegelinpainrelievingafterepisiotomy
AT fsaberi effectoflidocainegelinpainrelievingafterepisiotomy
_version_ 1718440322770403328