Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models

The assessment of the distribution of contact pressure on the meniscus is important in the elucidation of kinematics, etiology of joint diseases, and establishment of treatment methods. Compared with sensors widely used in recent years, pressure-sensitive conductive rubber sensors are easy to mold,...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Shunsuke Sezaki, Shuhei Otsuki, Kuniaki Ikeda, Nobuhiro Okuno, Yoshinori Okamoto, Hitoshi Wakama, Tomohiro Okayoshi, Masashi Neo
Formato: article
Lenguaje:EN
Publicado: Hindawi Limited 2021
Materias:
Acceso en línea:https://doaj.org/article/b620a271c78f429f98a4d78c52d46f02
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b620a271c78f429f98a4d78c52d46f02
record_format dspace
spelling oai:doaj.org-article:b620a271c78f429f98a4d78c52d46f022021-11-15T01:19:47ZDevelopment of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models1754-210310.1155/2021/4931092https://doaj.org/article/b620a271c78f429f98a4d78c52d46f022021-01-01T00:00:00Zhttp://dx.doi.org/10.1155/2021/4931092https://doaj.org/toc/1754-2103The assessment of the distribution of contact pressure on the meniscus is important in the elucidation of kinematics, etiology of joint diseases, and establishment of treatment methods. Compared with sensors widely used in recent years, pressure-sensitive conductive rubber sensors are easy to mold, flexible, durable, and resistant to shearing forces. This study is aimed at developing a rubber sensor for meniscal research and evaluating the pressure distribution after meniscal injury using porcine models. After confirming the reliability of the rubber sensor, contact pressure was obtained from the rubber sensor using the medial meniscus and femur of the porcine knee. Three test conditions of intact meniscus, radial tear, and meniscectomy were prepared, and a compressive load of 100 N was applied. After confirming the high reliability of the rubber sensor, the intact meniscus had the most uniform pressure distribution map, while the pressure in the meniscectomy model was concentrated in the resection region. The high-pressure region was significantly smaller in the intact group than in the radial tear models after 80 and 100 N (P<0.05). The rubber sensor captured the pressure concentration specific to each examination group and was useful for evaluating the relationship between the pattern of meniscal injury and changes in the biomechanical condition of the knee.Shunsuke SezakiShuhei OtsukiKuniaki IkedaNobuhiro OkunoYoshinori OkamotoHitoshi WakamaTomohiro OkayoshiMasashi NeoHindawi LimitedarticleBiotechnologyTP248.13-248.65Biology (General)QH301-705.5ENApplied Bionics and Biomechanics, Vol 2021 (2021)
institution DOAJ
collection DOAJ
language EN
topic Biotechnology
TP248.13-248.65
Biology (General)
QH301-705.5
spellingShingle Biotechnology
TP248.13-248.65
Biology (General)
QH301-705.5
Shunsuke Sezaki
Shuhei Otsuki
Kuniaki Ikeda
Nobuhiro Okuno
Yoshinori Okamoto
Hitoshi Wakama
Tomohiro Okayoshi
Masashi Neo
Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models
description The assessment of the distribution of contact pressure on the meniscus is important in the elucidation of kinematics, etiology of joint diseases, and establishment of treatment methods. Compared with sensors widely used in recent years, pressure-sensitive conductive rubber sensors are easy to mold, flexible, durable, and resistant to shearing forces. This study is aimed at developing a rubber sensor for meniscal research and evaluating the pressure distribution after meniscal injury using porcine models. After confirming the reliability of the rubber sensor, contact pressure was obtained from the rubber sensor using the medial meniscus and femur of the porcine knee. Three test conditions of intact meniscus, radial tear, and meniscectomy were prepared, and a compressive load of 100 N was applied. After confirming the high reliability of the rubber sensor, the intact meniscus had the most uniform pressure distribution map, while the pressure in the meniscectomy model was concentrated in the resection region. The high-pressure region was significantly smaller in the intact group than in the radial tear models after 80 and 100 N (P<0.05). The rubber sensor captured the pressure concentration specific to each examination group and was useful for evaluating the relationship between the pattern of meniscal injury and changes in the biomechanical condition of the knee.
format article
author Shunsuke Sezaki
Shuhei Otsuki
Kuniaki Ikeda
Nobuhiro Okuno
Yoshinori Okamoto
Hitoshi Wakama
Tomohiro Okayoshi
Masashi Neo
author_facet Shunsuke Sezaki
Shuhei Otsuki
Kuniaki Ikeda
Nobuhiro Okuno
Yoshinori Okamoto
Hitoshi Wakama
Tomohiro Okayoshi
Masashi Neo
author_sort Shunsuke Sezaki
title Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models
title_short Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models
title_full Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models
title_fullStr Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models
title_full_unstemmed Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models
title_sort development of a pressure-sensitive conductive rubber sensor for analyzing meniscal injury in porcine models
publisher Hindawi Limited
publishDate 2021
url https://doaj.org/article/b620a271c78f429f98a4d78c52d46f02
work_keys_str_mv AT shunsukesezaki developmentofapressuresensitiveconductiverubbersensorforanalyzingmeniscalinjuryinporcinemodels
AT shuheiotsuki developmentofapressuresensitiveconductiverubbersensorforanalyzingmeniscalinjuryinporcinemodels
AT kuniakiikeda developmentofapressuresensitiveconductiverubbersensorforanalyzingmeniscalinjuryinporcinemodels
AT nobuhirookuno developmentofapressuresensitiveconductiverubbersensorforanalyzingmeniscalinjuryinporcinemodels
AT yoshinoriokamoto developmentofapressuresensitiveconductiverubbersensorforanalyzingmeniscalinjuryinporcinemodels
AT hitoshiwakama developmentofapressuresensitiveconductiverubbersensorforanalyzingmeniscalinjuryinporcinemodels
AT tomohirookayoshi developmentofapressuresensitiveconductiverubbersensorforanalyzingmeniscalinjuryinporcinemodels
AT masashineo developmentofapressuresensitiveconductiverubbersensorforanalyzingmeniscalinjuryinporcinemodels
_version_ 1718428944670130176