CONTACT POTENTIAL DIFFERENCE AS A MEASURE OF POWER CABLE POLYMER INSULATION AGING
The paper shows dynamics of changing contact potential difference in power cables with cross-linked polyethylene insulation in the initial state and after additional thermal-radiation aging. The cable metal elements grounding is proposed to do before measurements in order to reduce the degree of sur...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN RU UK |
Publicado: |
National Technical University "Kharkiv Polytechnic Institute"
2014
|
Materias: | |
Acceso en línea: | https://doaj.org/article/b63de27eb4d34ed1848f312fd4d31a4c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:b63de27eb4d34ed1848f312fd4d31a4c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:b63de27eb4d34ed1848f312fd4d31a4c2021-12-02T16:32:19ZCONTACT POTENTIAL DIFFERENCE AS A MEASURE OF POWER CABLE POLYMER INSULATION AGING2074-272X2074-272Xhttps://doaj.org/article/b63de27eb4d34ed1848f312fd4d31a4c2014-10-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/28122/25062https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2074-272XThe paper shows dynamics of changing contact potential difference in power cables with cross-linked polyethylene insulation in the initial state and after additional thermal-radiation aging. The cable metal elements grounding is proposed to do before measurements in order to reduce the degree of surface charges action. It is experimentally revealed that the contact potential difference is a sensitive indicator of polymer insulation aging (oxidation) processes.A.V. BezprozvannychA.N. BoykoNational Technical University "Kharkiv Polytechnic Institute"articlecontact potential differencepower cablesthermal-radiation agingsurface chargespolymer insulation oxidationElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 5, Pp 62-66 (2014) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN RU UK |
topic |
contact potential difference power cables thermal-radiation aging surface charges polymer insulation oxidation Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
contact potential difference power cables thermal-radiation aging surface charges polymer insulation oxidation Electrical engineering. Electronics. Nuclear engineering TK1-9971 A.V. Bezprozvannych A.N. Boyko CONTACT POTENTIAL DIFFERENCE AS A MEASURE OF POWER CABLE POLYMER INSULATION AGING |
description |
The paper shows dynamics of changing contact potential difference in power cables with cross-linked polyethylene insulation in the initial state and after additional thermal-radiation aging. The cable metal elements grounding is proposed to do before measurements in order to reduce the degree of surface charges action. It is experimentally revealed that the contact potential difference is a sensitive indicator of polymer insulation aging (oxidation) processes. |
format |
article |
author |
A.V. Bezprozvannych A.N. Boyko |
author_facet |
A.V. Bezprozvannych A.N. Boyko |
author_sort |
A.V. Bezprozvannych |
title |
CONTACT POTENTIAL DIFFERENCE AS A MEASURE OF POWER CABLE POLYMER INSULATION AGING |
title_short |
CONTACT POTENTIAL DIFFERENCE AS A MEASURE OF POWER CABLE POLYMER INSULATION AGING |
title_full |
CONTACT POTENTIAL DIFFERENCE AS A MEASURE OF POWER CABLE POLYMER INSULATION AGING |
title_fullStr |
CONTACT POTENTIAL DIFFERENCE AS A MEASURE OF POWER CABLE POLYMER INSULATION AGING |
title_full_unstemmed |
CONTACT POTENTIAL DIFFERENCE AS A MEASURE OF POWER CABLE POLYMER INSULATION AGING |
title_sort |
contact potential difference as a measure of power cable polymer insulation aging |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
publishDate |
2014 |
url |
https://doaj.org/article/b63de27eb4d34ed1848f312fd4d31a4c |
work_keys_str_mv |
AT avbezprozvannych contactpotentialdifferenceasameasureofpowercablepolymerinsulationaging AT anboyko contactpotentialdifferenceasameasureofpowercablepolymerinsulationaging |
_version_ |
1718383830075703296 |