Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography

Sachi Kojima, Toshihiro Inoue, Takahiro Kawaji, Hidenobu TaniharaDepartment of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Chuo-ku, Kumamoto, JapanPurpose: To determine the clinical features of tear fluid signs associated with filtration blebs via three-dimensional anterior segmen...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kojima S, Inoue T, Kawaji T, Tanihara H
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://doaj.org/article/b63e7cf75cf344e7984dda59c15a886d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b63e7cf75cf344e7984dda59c15a886d
record_format dspace
spelling oai:doaj.org-article:b63e7cf75cf344e7984dda59c15a886d2021-12-02T02:46:50ZTear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography1177-5483https://doaj.org/article/b63e7cf75cf344e7984dda59c15a886d2014-04-01T00:00:00Zhttp://www.dovepress.com/tear-fluid-signs-associated-with-filtration-blebs-as-demonstrated-by-t-a16500https://doaj.org/toc/1177-5483 Sachi Kojima, Toshihiro Inoue, Takahiro Kawaji, Hidenobu TaniharaDepartment of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Chuo-ku, Kumamoto, JapanPurpose: To determine the clinical features of tear fluid signs associated with filtration blebs via three-dimensional anterior segment optical coherence tomography (3D AS-OCT).Methods: In total, 152 eyes (130 patients) with glaucoma that underwent trabeculectomy with mitomycin C were evaluated retrospectively. We investigated tear fluid signs associated with filtration blebs, using 3D AS-OCT with custom software, and compared the findings of lower tear meniscus. We also analyzed postoperative intraocular pressure and the bleb parameters of filtration blebs between eyes with and without tear fluid signs.Results: We found tear fluid signs associated with filtration blebs in 45 (30%) of 152 eyes. The mean postoperative intraocular pressure of the eyes with the tear fluid sign in a filtration bleb was significantly lower than that in eyes without the tear fluid sign (P<0.001). Blebs with tear fluid signs have more frequent identifiable filtration openings, greater total height, increased fluid-filled cavity height, and less wall intensity compared with blebs without these signs.Conclusion: We identified tear fluid signs in AS-OCT images on or along filtration blebs that depended on bleb morphology. The occurrence of these signs may be related to the presence of functional blebs, which may thereby control postoperative intraocular pressure.Keywords: filtration bleb, trabeculectomy, 3D AS-OCT, tear fluid signKojima SInoue TKawaji TTanihara HDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2014, Iss default, Pp 767-772 (2014)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Kojima S
Inoue T
Kawaji T
Tanihara H
Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
description Sachi Kojima, Toshihiro Inoue, Takahiro Kawaji, Hidenobu TaniharaDepartment of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Chuo-ku, Kumamoto, JapanPurpose: To determine the clinical features of tear fluid signs associated with filtration blebs via three-dimensional anterior segment optical coherence tomography (3D AS-OCT).Methods: In total, 152 eyes (130 patients) with glaucoma that underwent trabeculectomy with mitomycin C were evaluated retrospectively. We investigated tear fluid signs associated with filtration blebs, using 3D AS-OCT with custom software, and compared the findings of lower tear meniscus. We also analyzed postoperative intraocular pressure and the bleb parameters of filtration blebs between eyes with and without tear fluid signs.Results: We found tear fluid signs associated with filtration blebs in 45 (30%) of 152 eyes. The mean postoperative intraocular pressure of the eyes with the tear fluid sign in a filtration bleb was significantly lower than that in eyes without the tear fluid sign (P<0.001). Blebs with tear fluid signs have more frequent identifiable filtration openings, greater total height, increased fluid-filled cavity height, and less wall intensity compared with blebs without these signs.Conclusion: We identified tear fluid signs in AS-OCT images on or along filtration blebs that depended on bleb morphology. The occurrence of these signs may be related to the presence of functional blebs, which may thereby control postoperative intraocular pressure.Keywords: filtration bleb, trabeculectomy, 3D AS-OCT, tear fluid sign
format article
author Kojima S
Inoue T
Kawaji T
Tanihara H
author_facet Kojima S
Inoue T
Kawaji T
Tanihara H
author_sort Kojima S
title Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_short Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_full Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_fullStr Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_full_unstemmed Tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
title_sort tear fluid signs associated with filtration blebs, as demonstrated by three-dimensional anterior segment optical coherence tomography
publisher Dove Medical Press
publishDate 2014
url https://doaj.org/article/b63e7cf75cf344e7984dda59c15a886d
work_keys_str_mv AT kojimas tearfluidsignsassociatedwithfiltrationblebsasdemonstratedbythreedimensionalanteriorsegmentopticalcoherencetomography
AT inouet tearfluidsignsassociatedwithfiltrationblebsasdemonstratedbythreedimensionalanteriorsegmentopticalcoherencetomography
AT kawajit tearfluidsignsassociatedwithfiltrationblebsasdemonstratedbythreedimensionalanteriorsegmentopticalcoherencetomography
AT taniharah tearfluidsignsassociatedwithfiltrationblebsasdemonstratedbythreedimensionalanteriorsegmentopticalcoherencetomography
_version_ 1718402185694281728