Translation of a spinal bone cement product from bench to bedside

Spinal acrylic bone cements (ABCs) are used clinically for percutaneous vertebroplasty (PVP) and kyphoplasty (PKP) to treat osteoporotic vertebral compression fractures. Product translation of spinal ABC products followed the design control processes including design verification and validation. The...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Fei Feng, Mengmeng Chen, Xuan Wang, Hongwei Zhang, Hongtao Nie, Hai Tang
Formato: article
Lenguaje:EN
Publicado: KeAi Communications Co., Ltd. 2022
Materias:
Acceso en línea:https://doaj.org/article/b6864fca4c984bcd85e6a23a16e39396
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b6864fca4c984bcd85e6a23a16e39396
record_format dspace
spelling oai:doaj.org-article:b6864fca4c984bcd85e6a23a16e393962021-11-28T04:35:06ZTranslation of a spinal bone cement product from bench to bedside2452-199X10.1016/j.bioactmat.2021.08.011https://doaj.org/article/b6864fca4c984bcd85e6a23a16e393962022-04-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S2452199X21003881https://doaj.org/toc/2452-199XSpinal acrylic bone cements (ABCs) are used clinically for percutaneous vertebroplasty (PVP) and kyphoplasty (PKP) to treat osteoporotic vertebral compression fractures. Product translation of spinal ABC products followed the design control processes including design verification and validation. The bench to bedside translation of the first Chinese spinal ABC product (Alliment®, namely Alliment Cement) approved by National Medical Products Administration of China was investigated and another commercial product served as the control (Osteopal®V, namely Osteopal V Cement). Results of non-clinical bench performance verification tests of compression, bending and monomer release showed that the newly marketed Alliment Cement is similar to the Osteopal V Cement with properties of both meeting the criteria specified by standards. The Alliment Cement demonstrated good biocompatibility during the 26 weeks’ bone implantation test. Porcine cadaver validation tests further revealed that the Alliment Cement satisfied the needs for both PVP and PKP procedures. A post-approval, retrospective clinical investigation further demonstrated the safety and efficacy of the Alliment Cement, with a significant reduction of pain and the improved stability of the fractured vertebral bodies. A successful translation of biomaterial medical products needs close collaborations among academia, industry, healthcare professionals and regulatory agencies.Fei FengMengmeng ChenXuan WangHongwei ZhangHongtao NieHai TangKeAi Communications Co., Ltd.articleBone cementSpineTranslational researchVertebroplastyKyphoplastySafety and efficacyMaterials of engineering and construction. Mechanics of materialsTA401-492Biology (General)QH301-705.5ENBioactive Materials, Vol 10, Iss , Pp 345-354 (2022)
institution DOAJ
collection DOAJ
language EN
topic Bone cement
Spine
Translational research
Vertebroplasty
Kyphoplasty
Safety and efficacy
Materials of engineering and construction. Mechanics of materials
TA401-492
Biology (General)
QH301-705.5
spellingShingle Bone cement
Spine
Translational research
Vertebroplasty
Kyphoplasty
Safety and efficacy
Materials of engineering and construction. Mechanics of materials
TA401-492
Biology (General)
QH301-705.5
Fei Feng
Mengmeng Chen
Xuan Wang
Hongwei Zhang
Hongtao Nie
Hai Tang
Translation of a spinal bone cement product from bench to bedside
description Spinal acrylic bone cements (ABCs) are used clinically for percutaneous vertebroplasty (PVP) and kyphoplasty (PKP) to treat osteoporotic vertebral compression fractures. Product translation of spinal ABC products followed the design control processes including design verification and validation. The bench to bedside translation of the first Chinese spinal ABC product (Alliment®, namely Alliment Cement) approved by National Medical Products Administration of China was investigated and another commercial product served as the control (Osteopal®V, namely Osteopal V Cement). Results of non-clinical bench performance verification tests of compression, bending and monomer release showed that the newly marketed Alliment Cement is similar to the Osteopal V Cement with properties of both meeting the criteria specified by standards. The Alliment Cement demonstrated good biocompatibility during the 26 weeks’ bone implantation test. Porcine cadaver validation tests further revealed that the Alliment Cement satisfied the needs for both PVP and PKP procedures. A post-approval, retrospective clinical investigation further demonstrated the safety and efficacy of the Alliment Cement, with a significant reduction of pain and the improved stability of the fractured vertebral bodies. A successful translation of biomaterial medical products needs close collaborations among academia, industry, healthcare professionals and regulatory agencies.
format article
author Fei Feng
Mengmeng Chen
Xuan Wang
Hongwei Zhang
Hongtao Nie
Hai Tang
author_facet Fei Feng
Mengmeng Chen
Xuan Wang
Hongwei Zhang
Hongtao Nie
Hai Tang
author_sort Fei Feng
title Translation of a spinal bone cement product from bench to bedside
title_short Translation of a spinal bone cement product from bench to bedside
title_full Translation of a spinal bone cement product from bench to bedside
title_fullStr Translation of a spinal bone cement product from bench to bedside
title_full_unstemmed Translation of a spinal bone cement product from bench to bedside
title_sort translation of a spinal bone cement product from bench to bedside
publisher KeAi Communications Co., Ltd.
publishDate 2022
url https://doaj.org/article/b6864fca4c984bcd85e6a23a16e39396
work_keys_str_mv AT feifeng translationofaspinalbonecementproductfrombenchtobedside
AT mengmengchen translationofaspinalbonecementproductfrombenchtobedside
AT xuanwang translationofaspinalbonecementproductfrombenchtobedside
AT hongweizhang translationofaspinalbonecementproductfrombenchtobedside
AT hongtaonie translationofaspinalbonecementproductfrombenchtobedside
AT haitang translationofaspinalbonecementproductfrombenchtobedside
_version_ 1718408340649803776