Analysis of Office Rooms Energy Consumption Data in Respect to Meteorological and Direct Sun Exposure Conditions

There are many papers concerning the consumption of energy in different buildings. Most describe residential buildings, with only a few about office- or public service buildings. Few articles showcase the use of energy consumption in specific rooms of a building, directed in different geographical d...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Adam Kula, Albert Smalcerz, Maciej Sajkowski, Zygmunt Kamiński
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
T
Acceso en línea:https://doaj.org/article/b752cb796e5943b59619e445e1885e9d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b752cb796e5943b59619e445e1885e9d
record_format dspace
spelling oai:doaj.org-article:b752cb796e5943b59619e445e1885e9d2021-11-25T17:26:59ZAnalysis of Office Rooms Energy Consumption Data in Respect to Meteorological and Direct Sun Exposure Conditions10.3390/en142275901996-1073https://doaj.org/article/b752cb796e5943b59619e445e1885e9d2021-11-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/22/7590https://doaj.org/toc/1996-1073There are many papers concerning the consumption of energy in different buildings. Most describe residential buildings, with only a few about office- or public service buildings. Few articles showcase the use of energy consumption in specific rooms of a building, directed in different geographical directions. On the other hand, many publications present methods, such as machine learning or AI, for building energy management and prediction of its consumption. These methods have limitations and represent a certain level of uncertainty. In order to compare energy consumption of different rooms, the measurements of particular building-room parameters were collected and analyzed. The obtained results showcase the effect of room location, regarding geographical directions, for the consumption of energy for heating. For south-exposed rooms, due to sun radiation, it is possible to switch heating off completely, and even overheating of 3 °C above the 22 °C temperature set point occurs. The impact of the sun radiation for rooms with a window directed east or west reached about 1 °C and lasts for a few hours before noon for the east, and until late afternoon for the west.Adam KulaAlbert SmalcerzMaciej SajkowskiZygmunt KamińskiMDPI AGarticleoffice buildingenergy consumptionmeteorological parametersdata analysisPolandTechnologyTENEnergies, Vol 14, Iss 7590, p 7590 (2021)
institution DOAJ
collection DOAJ
language EN
topic office building
energy consumption
meteorological parameters
data analysis
Poland
Technology
T
spellingShingle office building
energy consumption
meteorological parameters
data analysis
Poland
Technology
T
Adam Kula
Albert Smalcerz
Maciej Sajkowski
Zygmunt Kamiński
Analysis of Office Rooms Energy Consumption Data in Respect to Meteorological and Direct Sun Exposure Conditions
description There are many papers concerning the consumption of energy in different buildings. Most describe residential buildings, with only a few about office- or public service buildings. Few articles showcase the use of energy consumption in specific rooms of a building, directed in different geographical directions. On the other hand, many publications present methods, such as machine learning or AI, for building energy management and prediction of its consumption. These methods have limitations and represent a certain level of uncertainty. In order to compare energy consumption of different rooms, the measurements of particular building-room parameters were collected and analyzed. The obtained results showcase the effect of room location, regarding geographical directions, for the consumption of energy for heating. For south-exposed rooms, due to sun radiation, it is possible to switch heating off completely, and even overheating of 3 °C above the 22 °C temperature set point occurs. The impact of the sun radiation for rooms with a window directed east or west reached about 1 °C and lasts for a few hours before noon for the east, and until late afternoon for the west.
format article
author Adam Kula
Albert Smalcerz
Maciej Sajkowski
Zygmunt Kamiński
author_facet Adam Kula
Albert Smalcerz
Maciej Sajkowski
Zygmunt Kamiński
author_sort Adam Kula
title Analysis of Office Rooms Energy Consumption Data in Respect to Meteorological and Direct Sun Exposure Conditions
title_short Analysis of Office Rooms Energy Consumption Data in Respect to Meteorological and Direct Sun Exposure Conditions
title_full Analysis of Office Rooms Energy Consumption Data in Respect to Meteorological and Direct Sun Exposure Conditions
title_fullStr Analysis of Office Rooms Energy Consumption Data in Respect to Meteorological and Direct Sun Exposure Conditions
title_full_unstemmed Analysis of Office Rooms Energy Consumption Data in Respect to Meteorological and Direct Sun Exposure Conditions
title_sort analysis of office rooms energy consumption data in respect to meteorological and direct sun exposure conditions
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/b752cb796e5943b59619e445e1885e9d
work_keys_str_mv AT adamkula analysisofofficeroomsenergyconsumptiondatainrespecttometeorologicalanddirectsunexposureconditions
AT albertsmalcerz analysisofofficeroomsenergyconsumptiondatainrespecttometeorologicalanddirectsunexposureconditions
AT maciejsajkowski analysisofofficeroomsenergyconsumptiondatainrespecttometeorologicalanddirectsunexposureconditions
AT zygmuntkaminski analysisofofficeroomsenergyconsumptiondatainrespecttometeorologicalanddirectsunexposureconditions
_version_ 1718412370843271168