Single 3.3 fs multiple plate compression light source in ultrafast transient absorption spectroscopy
Abstract Ultrafast transient absorption spectroscopy is a powerful tool to reveal excited state dynamics in various materials. Conventionally, probe pulses are generated via bulk supercontinuum generation or (noncollinear) optical parametric amplifiers whilst pump pulses are generated separately usi...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/b793836193ce41bda32529a44361bb7d |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:b793836193ce41bda32529a44361bb7d |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:b793836193ce41bda32529a44361bb7d2021-12-02T17:23:16ZSingle 3.3 fs multiple plate compression light source in ultrafast transient absorption spectroscopy10.1038/s41598-021-92102-52045-2322https://doaj.org/article/b793836193ce41bda32529a44361bb7d2021-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-92102-5https://doaj.org/toc/2045-2322Abstract Ultrafast transient absorption spectroscopy is a powerful tool to reveal excited state dynamics in various materials. Conventionally, probe pulses are generated via bulk supercontinuum generation or (noncollinear) optical parametric amplifiers whilst pump pulses are generated separately using (noncollinear) optical parametric amplifiers. These systems are limited by either their spectral density, stability, spectral range, and/or temporal compressibility. Recently, a new intense broadband light source is being developed, the multi-plate compression, which promises to overcome these limitations. In this paper, we analyze the supercontinuum generated by a single Multiple Plate Compression system to set a benchmark for its use in the field of ultrafast pump-probe spectroscopy. We have compressed the supercontinuum to 3.3 fs using chirp mirrors alone, making it an excellent candidate for pump-probe experiments requiring high temporal resolution. Furthermore, the single light source can be used to generate both probe and pump pulses due to its high spectral density (>14.5 nJ/nm) between 490 and 890 nm. The intensity has an average shot-to-shot relative standard deviation of 4.6 % over 490 to 890 nm, calculated over 2,000 sequential shots. By using only 1,000 shot pairs, a $$\Delta T/T$$ Δ T / T noise level of $$2.6\times 10^{-4}$$ 2.6 × 10 - 4 RMS is achieved. Finally, as a proof of concept, the transient absorption spectrum of a methylammonium lead iodide perovskite film is taken, showing great signal to noise with only 1,000 shot pairs. These results show great potential for the employment of this technique in other spectroscopic techniques such as coherent multidimensional spectroscopy.Ronnie R. TammingChao-Yang LinJustin M. HodgkissShang-Da YangKai ChenChih-Hsuan LuNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Ronnie R. Tamming Chao-Yang Lin Justin M. Hodgkiss Shang-Da Yang Kai Chen Chih-Hsuan Lu Single 3.3 fs multiple plate compression light source in ultrafast transient absorption spectroscopy |
description |
Abstract Ultrafast transient absorption spectroscopy is a powerful tool to reveal excited state dynamics in various materials. Conventionally, probe pulses are generated via bulk supercontinuum generation or (noncollinear) optical parametric amplifiers whilst pump pulses are generated separately using (noncollinear) optical parametric amplifiers. These systems are limited by either their spectral density, stability, spectral range, and/or temporal compressibility. Recently, a new intense broadband light source is being developed, the multi-plate compression, which promises to overcome these limitations. In this paper, we analyze the supercontinuum generated by a single Multiple Plate Compression system to set a benchmark for its use in the field of ultrafast pump-probe spectroscopy. We have compressed the supercontinuum to 3.3 fs using chirp mirrors alone, making it an excellent candidate for pump-probe experiments requiring high temporal resolution. Furthermore, the single light source can be used to generate both probe and pump pulses due to its high spectral density (>14.5 nJ/nm) between 490 and 890 nm. The intensity has an average shot-to-shot relative standard deviation of 4.6 % over 490 to 890 nm, calculated over 2,000 sequential shots. By using only 1,000 shot pairs, a $$\Delta T/T$$ Δ T / T noise level of $$2.6\times 10^{-4}$$ 2.6 × 10 - 4 RMS is achieved. Finally, as a proof of concept, the transient absorption spectrum of a methylammonium lead iodide perovskite film is taken, showing great signal to noise with only 1,000 shot pairs. These results show great potential for the employment of this technique in other spectroscopic techniques such as coherent multidimensional spectroscopy. |
format |
article |
author |
Ronnie R. Tamming Chao-Yang Lin Justin M. Hodgkiss Shang-Da Yang Kai Chen Chih-Hsuan Lu |
author_facet |
Ronnie R. Tamming Chao-Yang Lin Justin M. Hodgkiss Shang-Da Yang Kai Chen Chih-Hsuan Lu |
author_sort |
Ronnie R. Tamming |
title |
Single 3.3 fs multiple plate compression light source in ultrafast transient absorption spectroscopy |
title_short |
Single 3.3 fs multiple plate compression light source in ultrafast transient absorption spectroscopy |
title_full |
Single 3.3 fs multiple plate compression light source in ultrafast transient absorption spectroscopy |
title_fullStr |
Single 3.3 fs multiple plate compression light source in ultrafast transient absorption spectroscopy |
title_full_unstemmed |
Single 3.3 fs multiple plate compression light source in ultrafast transient absorption spectroscopy |
title_sort |
single 3.3 fs multiple plate compression light source in ultrafast transient absorption spectroscopy |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/b793836193ce41bda32529a44361bb7d |
work_keys_str_mv |
AT ronniertamming single33fsmultipleplatecompressionlightsourceinultrafasttransientabsorptionspectroscopy AT chaoyanglin single33fsmultipleplatecompressionlightsourceinultrafasttransientabsorptionspectroscopy AT justinmhodgkiss single33fsmultipleplatecompressionlightsourceinultrafasttransientabsorptionspectroscopy AT shangdayang single33fsmultipleplatecompressionlightsourceinultrafasttransientabsorptionspectroscopy AT kaichen single33fsmultipleplatecompressionlightsourceinultrafasttransientabsorptionspectroscopy AT chihhsuanlu single33fsmultipleplatecompressionlightsourceinultrafasttransientabsorptionspectroscopy |
_version_ |
1718380990999560192 |