Bone Conduction Stimulated VEMP Using the B250 Transducer

Karl-Johan Fredén Jansson,1 Bo Håkansson,1 Sabine Reinfeldt,1 Ann-Charlotte Persson,2 Måns Eeg-Olofsson2 1Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden; 2Department of Otolaryngology, Head and Neck Surgery, Sahlgrenska Academy, University of Gothenburg,...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Fredén Jansson KJ, Håkansson B, Reinfeldt S, Persson AC, Eeg-Olofsson M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2021
Materias:
Acceso en línea:https://doaj.org/article/b8362a09b29244d6861b803a3fe289e2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b8362a09b29244d6861b803a3fe289e2
record_format dspace
spelling oai:doaj.org-article:b8362a09b29244d6861b803a3fe289e22021-12-02T15:23:24ZBone Conduction Stimulated VEMP Using the B250 Transducer1179-1470https://doaj.org/article/b8362a09b29244d6861b803a3fe289e22021-07-01T00:00:00Zhttps://www.dovepress.com/bone-conduction-stimulated-vemp-using-the-b250-transducer-peer-reviewed-fulltext-article-MDERhttps://doaj.org/toc/1179-1470Karl-Johan Fredén Jansson,1 Bo Håkansson,1 Sabine Reinfeldt,1 Ann-Charlotte Persson,2 Måns Eeg-Olofsson2 1Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden; 2Department of Otolaryngology, Head and Neck Surgery, Sahlgrenska Academy, University of Gothenburg, Gothenburg, SwedenCorrespondence: Karl-Johan Fredén JanssonDepartment of Electrical Engineering, Chalmers University of Technology, Gothenburg, 41296, SwedenTel +46 31 772 1783Email karljohf@chalmers.seObjective: Bone conduction (BC) stimulation is rarely used for clinical testing of vestibular evoked myogenic potentials (VEMPs) due to the limitations of conventional stimulation alternatives. The aim of this study is to compare VEMP using the new B250 transducer with the Minishaker and air conduction (AC) stimulation.Methods: Thirty normal subjects between 20 and 37 years old and equal gender distribution were recruited, 15 for ocular VEMP and 15 for cervical VEMP. Four stimulation conditions were compared: B250 on the mastoid (FM); Minishaker and B250 on the forehead (FZ); and AC stimulation using an insert earphone.Results: It was found that B250 at FM required a statistically significant lower hearing level than with AC stimulation, in average 41 dB and 35 dB lower for ocular VEMP and cervical VEMP, respectively, but gave longer n10 (1.1 ms) and n23 (1.6 ms). No statistical difference was found between B250 at FM and Minishaker at FZ.Conclusion: VEMP stimulated with B250 at FM gave similar response as the Minishaker at FZ and for a much lower hearing level than AC stimulation using insert earphones.Keywords: bone conduction, vestibular evoked myogenic potential, B250Fredén Jansson KJHåkansson BReinfeldt SPersson ACEeg-Olofsson MDove Medical Pressarticlebone conductionvestibular evoked myogenic potentialb250Medical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol Volume 14, Pp 225-237 (2021)
institution DOAJ
collection DOAJ
language EN
topic bone conduction
vestibular evoked myogenic potential
b250
Medical technology
R855-855.5
spellingShingle bone conduction
vestibular evoked myogenic potential
b250
Medical technology
R855-855.5
Fredén Jansson KJ
Håkansson B
Reinfeldt S
Persson AC
Eeg-Olofsson M
Bone Conduction Stimulated VEMP Using the B250 Transducer
description Karl-Johan Fredén Jansson,1 Bo Håkansson,1 Sabine Reinfeldt,1 Ann-Charlotte Persson,2 Måns Eeg-Olofsson2 1Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden; 2Department of Otolaryngology, Head and Neck Surgery, Sahlgrenska Academy, University of Gothenburg, Gothenburg, SwedenCorrespondence: Karl-Johan Fredén JanssonDepartment of Electrical Engineering, Chalmers University of Technology, Gothenburg, 41296, SwedenTel +46 31 772 1783Email karljohf@chalmers.seObjective: Bone conduction (BC) stimulation is rarely used for clinical testing of vestibular evoked myogenic potentials (VEMPs) due to the limitations of conventional stimulation alternatives. The aim of this study is to compare VEMP using the new B250 transducer with the Minishaker and air conduction (AC) stimulation.Methods: Thirty normal subjects between 20 and 37 years old and equal gender distribution were recruited, 15 for ocular VEMP and 15 for cervical VEMP. Four stimulation conditions were compared: B250 on the mastoid (FM); Minishaker and B250 on the forehead (FZ); and AC stimulation using an insert earphone.Results: It was found that B250 at FM required a statistically significant lower hearing level than with AC stimulation, in average 41 dB and 35 dB lower for ocular VEMP and cervical VEMP, respectively, but gave longer n10 (1.1 ms) and n23 (1.6 ms). No statistical difference was found between B250 at FM and Minishaker at FZ.Conclusion: VEMP stimulated with B250 at FM gave similar response as the Minishaker at FZ and for a much lower hearing level than AC stimulation using insert earphones.Keywords: bone conduction, vestibular evoked myogenic potential, B250
format article
author Fredén Jansson KJ
Håkansson B
Reinfeldt S
Persson AC
Eeg-Olofsson M
author_facet Fredén Jansson KJ
Håkansson B
Reinfeldt S
Persson AC
Eeg-Olofsson M
author_sort Fredén Jansson KJ
title Bone Conduction Stimulated VEMP Using the B250 Transducer
title_short Bone Conduction Stimulated VEMP Using the B250 Transducer
title_full Bone Conduction Stimulated VEMP Using the B250 Transducer
title_fullStr Bone Conduction Stimulated VEMP Using the B250 Transducer
title_full_unstemmed Bone Conduction Stimulated VEMP Using the B250 Transducer
title_sort bone conduction stimulated vemp using the b250 transducer
publisher Dove Medical Press
publishDate 2021
url https://doaj.org/article/b8362a09b29244d6861b803a3fe289e2
work_keys_str_mv AT fredenjanssonkj boneconductionstimulatedvempusingtheb250transducer
AT hakanssonb boneconductionstimulatedvempusingtheb250transducer
AT reinfeldts boneconductionstimulatedvempusingtheb250transducer
AT perssonac boneconductionstimulatedvempusingtheb250transducer
AT eegolofssonm boneconductionstimulatedvempusingtheb250transducer
_version_ 1718387288030838784