EFFICIENT SHIELDING OF THREE-PHASE CABLE LINE MAGNETIC FIELD BY PASSIVE LOOP UNDER LIMITED THERMAL EFFECT ON POWER CABLES
This paper deals with a mitigation of a three-phase cable line magnetic field by a new type of passive shield. We consider a cable line with a flat arrangement of cables. The developed single-loop shield has an asymmetric magnetic coupling with the cable line, due to the use of two different ferroma...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN RU UK |
Publicado: |
National Technical University "Kharkiv Polytechnic Institute"
2019
|
Materias: | |
Acceso en línea: | https://doaj.org/article/b8501a4ce0994e388035baf84903ec97 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:b8501a4ce0994e388035baf84903ec97 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:b8501a4ce0994e388035baf84903ec972021-12-02T18:44:36ZEFFICIENT SHIELDING OF THREE-PHASE CABLE LINE MAGNETIC FIELD BY PASSIVE LOOP UNDER LIMITED THERMAL EFFECT ON POWER CABLES10.20998/2074-272X.2019.6.072074-272X2309-3404https://doaj.org/article/b8501a4ce0994e388035baf84903ec972019-12-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2019.6.07/188000https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404This paper deals with a mitigation of a three-phase cable line magnetic field by a new type of passive shield. We consider a cable line with a flat arrangement of cables. The developed single-loop shield has an asymmetric magnetic coupling with the cable line, due to the use of two different ferromagnetic cores. Its high shielding efficiency is experimentally confirmed. As the developed shield is 0.2÷0.3 m away from the cable line, its thermal effect on the cable line is negligible. As the result, we obtain expressions for the shielding efficiency, parameters of the shield and the cores. V. Yu. RozovV. S. GrinchenkoA. V. YerisovP. N. DobrodeyevNational Technical University "Kharkiv Polytechnic Institute"articlecable linemagnetic fieldpassive loopshieldingmagnetic coreElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 6, Pp 50-54 (2019) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN RU UK |
topic |
cable line magnetic field passive loop shielding magnetic core Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
cable line magnetic field passive loop shielding magnetic core Electrical engineering. Electronics. Nuclear engineering TK1-9971 V. Yu. Rozov V. S. Grinchenko A. V. Yerisov P. N. Dobrodeyev EFFICIENT SHIELDING OF THREE-PHASE CABLE LINE MAGNETIC FIELD BY PASSIVE LOOP UNDER LIMITED THERMAL EFFECT ON POWER CABLES |
description |
This paper deals with a mitigation of a three-phase cable line magnetic field by a new type of passive shield. We consider a cable line with a flat arrangement of cables. The developed single-loop shield has an asymmetric magnetic coupling with the cable line, due to the use of two different ferromagnetic cores. Its high shielding efficiency is experimentally confirmed. As the developed shield is 0.2÷0.3 m away from the cable line, its thermal effect on the cable line is negligible. As the result, we obtain expressions for the shielding efficiency, parameters of the shield and the cores. |
format |
article |
author |
V. Yu. Rozov V. S. Grinchenko A. V. Yerisov P. N. Dobrodeyev |
author_facet |
V. Yu. Rozov V. S. Grinchenko A. V. Yerisov P. N. Dobrodeyev |
author_sort |
V. Yu. Rozov |
title |
EFFICIENT SHIELDING OF THREE-PHASE CABLE LINE MAGNETIC FIELD BY PASSIVE LOOP UNDER LIMITED THERMAL EFFECT ON POWER CABLES |
title_short |
EFFICIENT SHIELDING OF THREE-PHASE CABLE LINE MAGNETIC FIELD BY PASSIVE LOOP UNDER LIMITED THERMAL EFFECT ON POWER CABLES |
title_full |
EFFICIENT SHIELDING OF THREE-PHASE CABLE LINE MAGNETIC FIELD BY PASSIVE LOOP UNDER LIMITED THERMAL EFFECT ON POWER CABLES |
title_fullStr |
EFFICIENT SHIELDING OF THREE-PHASE CABLE LINE MAGNETIC FIELD BY PASSIVE LOOP UNDER LIMITED THERMAL EFFECT ON POWER CABLES |
title_full_unstemmed |
EFFICIENT SHIELDING OF THREE-PHASE CABLE LINE MAGNETIC FIELD BY PASSIVE LOOP UNDER LIMITED THERMAL EFFECT ON POWER CABLES |
title_sort |
efficient shielding of three-phase cable line magnetic field by passive loop under limited thermal effect on power cables |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
publishDate |
2019 |
url |
https://doaj.org/article/b8501a4ce0994e388035baf84903ec97 |
work_keys_str_mv |
AT vyurozov efficientshieldingofthreephasecablelinemagneticfieldbypassiveloopunderlimitedthermaleffectonpowercables AT vsgrinchenko efficientshieldingofthreephasecablelinemagneticfieldbypassiveloopunderlimitedthermaleffectonpowercables AT avyerisov efficientshieldingofthreephasecablelinemagneticfieldbypassiveloopunderlimitedthermaleffectonpowercables AT pndobrodeyev efficientshieldingofthreephasecablelinemagneticfieldbypassiveloopunderlimitedthermaleffectonpowercables |
_version_ |
1718377762431959040 |