A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian
Hung-Yuan Lin,1–3 Yi-Ting Fang,4 Ya-Jung Chuang,5 Justin N Karlin,6 Hsin-Yang Chen,7 Szu-Yuan Lin,8 Pi-Jung Lin,9 Ming Chen10 1Universal Eye Center, Zhong-Li, Taiwan, Republic of China; 2Department of Optometry, Central Taiwan University of Science and Technology, Taichung, Taiwan, Republ...
Guardado en:
Autores principales: | , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/b8a162104b2446bf9b33281877ad7409 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:b8a162104b2446bf9b33281877ad7409 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:b8a162104b2446bf9b33281877ad74092021-12-02T02:52:42ZA comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian1177-5483https://doaj.org/article/b8a162104b2446bf9b33281877ad74092017-02-01T00:00:00Zhttps://www.dovepress.com/a-comparison-of-three-different-corneal-marking-methods-used-to-determ-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Hung-Yuan Lin,1–3 Yi-Ting Fang,4 Ya-Jung Chuang,5 Justin N Karlin,6 Hsin-Yang Chen,7 Szu-Yuan Lin,8 Pi-Jung Lin,9 Ming Chen10 1Universal Eye Center, Zhong-Li, Taiwan, Republic of China; 2Department of Optometry, Central Taiwan University of Science and Technology, Taichung, Taiwan, Republic of China; 3Department of Ophthalmology, Fu-Jian Medical University, People’s Republic of China; 4Universal Eye Center, Taoyuan, Taiwan, Republic of China; 5Universal Eye Center, Long-Tan, Taiwan, Republic of China; 6Department of Ophthalmology, University of Virginia, Charlottesville, VA, USA; 7Department of Ophthalmology, Ningbo First Hospital, People’s Republic of China; 8Department of Ophthalmology, Cathay General Hospital, 9Universal Eye Center, Taipei, Taiwan, Republic of China; 10Department of Surgery, Division of Ophthalmology, John A Burns School of Medicine, University of Hawaii, Honolulu, HI, USA Abstract: During toric intraocular lens (IOL) implantation, surgeons must take particular care to ensure that inaccurate preoperative measurement and intraoperative misalignment do not cause unexpected postoperative residual astigmatism. This retrospective, comparative case series study aimed to analyze the rotational deviation, or cyclotorsion, of three corneal marking methods: VERION digital marker (VDM; reference), horizontal slit beam marking (HSBM), and subjective direct visual marking (SDVM) on the table (using a bevel knife tip). Subjects included 81 eyes of 61 patients (mean age: 65.70±13.14 years; range: 32–91 years) undergoing scheduled cataract surgery. A preoperative reference image was taken of each eye. Subsequently, a slit lamp with the light beam turned to the horizontal meridian was used to align the seated patient’s head, and two reference marks were placed at the 3- and 9-o’clock positions of the corneal limbus using a 27-gauge needle and marking pen (HSBM). Upon transfer to the surgical table, the VDM was used to display a real-time dial scale on the patient’s eye, with the entrance of the temporal clear corneal incision (CCI) at 0° (horizontal meridian). Simultaneously, a bevel knife tip was used to create a marker based on the surgeon’s visual determination of the temporal 0° point (SDVM). We used the VDM to quantitatively evaluate the accuracy of axis alignment via deviation from the horizontal reference meridian. Compared with the reference meridian, the SDVM (–3.46°±7.32°, range: –18° to 13°) exhibited greater average relative cyclotorsion versus the HSBM (0.41°±4.92°, range: –10° to 10°). Furthermore, the mean average misalignment was significantly less in the HSBM group versus the SDVM group (t=4.179, P<0.001). The VDM is likely a reliable marking method, similar to the HSBM. In contrast, the SDVM is not entirely reliable. The VDM usage may prevent inaccurate preoperative manual marking during toric IOL implantation. Keywords: VERION digital marker, horizontal slit beam marking, subjective direct visual markingLin HYFang YTChuang YJKarlin JNChen HYLin SYLin PJChen MDove Medical PressarticleVERION digital markerhorizontal slit beam markingsubjective direct visual markingOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 11, Pp 311-315 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
VERION digital marker horizontal slit beam marking subjective direct visual marking Ophthalmology RE1-994 |
spellingShingle |
VERION digital marker horizontal slit beam marking subjective direct visual marking Ophthalmology RE1-994 Lin HY Fang YT Chuang YJ Karlin JN Chen HY Lin SY Lin PJ Chen M A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian |
description |
Hung-Yuan Lin,1–3 Yi-Ting Fang,4 Ya-Jung Chuang,5 Justin N Karlin,6 Hsin-Yang Chen,7 Szu-Yuan Lin,8 Pi-Jung Lin,9 Ming Chen10 1Universal Eye Center, Zhong-Li, Taiwan, Republic of China; 2Department of Optometry, Central Taiwan University of Science and Technology, Taichung, Taiwan, Republic of China; 3Department of Ophthalmology, Fu-Jian Medical University, People’s Republic of China; 4Universal Eye Center, Taoyuan, Taiwan, Republic of China; 5Universal Eye Center, Long-Tan, Taiwan, Republic of China; 6Department of Ophthalmology, University of Virginia, Charlottesville, VA, USA; 7Department of Ophthalmology, Ningbo First Hospital, People’s Republic of China; 8Department of Ophthalmology, Cathay General Hospital, 9Universal Eye Center, Taipei, Taiwan, Republic of China; 10Department of Surgery, Division of Ophthalmology, John A Burns School of Medicine, University of Hawaii, Honolulu, HI, USA Abstract: During toric intraocular lens (IOL) implantation, surgeons must take particular care to ensure that inaccurate preoperative measurement and intraoperative misalignment do not cause unexpected postoperative residual astigmatism. This retrospective, comparative case series study aimed to analyze the rotational deviation, or cyclotorsion, of three corneal marking methods: VERION digital marker (VDM; reference), horizontal slit beam marking (HSBM), and subjective direct visual marking (SDVM) on the table (using a bevel knife tip). Subjects included 81 eyes of 61 patients (mean age: 65.70±13.14 years; range: 32–91 years) undergoing scheduled cataract surgery. A preoperative reference image was taken of each eye. Subsequently, a slit lamp with the light beam turned to the horizontal meridian was used to align the seated patient’s head, and two reference marks were placed at the 3- and 9-o’clock positions of the corneal limbus using a 27-gauge needle and marking pen (HSBM). Upon transfer to the surgical table, the VDM was used to display a real-time dial scale on the patient’s eye, with the entrance of the temporal clear corneal incision (CCI) at 0° (horizontal meridian). Simultaneously, a bevel knife tip was used to create a marker based on the surgeon’s visual determination of the temporal 0° point (SDVM). We used the VDM to quantitatively evaluate the accuracy of axis alignment via deviation from the horizontal reference meridian. Compared with the reference meridian, the SDVM (–3.46°±7.32°, range: –18° to 13°) exhibited greater average relative cyclotorsion versus the HSBM (0.41°±4.92°, range: –10° to 10°). Furthermore, the mean average misalignment was significantly less in the HSBM group versus the SDVM group (t=4.179, P<0.001). The VDM is likely a reliable marking method, similar to the HSBM. In contrast, the SDVM is not entirely reliable. The VDM usage may prevent inaccurate preoperative manual marking during toric IOL implantation. Keywords: VERION digital marker, horizontal slit beam marking, subjective direct visual marking |
format |
article |
author |
Lin HY Fang YT Chuang YJ Karlin JN Chen HY Lin SY Lin PJ Chen M |
author_facet |
Lin HY Fang YT Chuang YJ Karlin JN Chen HY Lin SY Lin PJ Chen M |
author_sort |
Lin HY |
title |
A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian |
title_short |
A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian |
title_full |
A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian |
title_fullStr |
A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian |
title_full_unstemmed |
A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian |
title_sort |
comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian |
publisher |
Dove Medical Press |
publishDate |
2017 |
url |
https://doaj.org/article/b8a162104b2446bf9b33281877ad7409 |
work_keys_str_mv |
AT linhy acomparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT fangyt acomparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT chuangyj acomparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT karlinjn acomparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT chenhy acomparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT linsy acomparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT linpj acomparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT chenm acomparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT linhy comparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT fangyt comparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT chuangyj comparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT karlinjn comparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT chenhy comparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT linsy comparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT linpj comparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian AT chenm comparisonofthreedifferentcornealmarkingmethodsusedtodeterminecyclotorsioninthehorizontalmeridian |
_version_ |
1718402122225025024 |