Distinct SARS-CoV-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray

Abstract A coronavirus antigen microarray (COVAM) was constructed containing 11 SARS-CoV-2, 5 SARS-1, 5 MERS, and 12 seasonal coronavirus recombinant proteins. The array is designed to measure immunoglobulin isotype and subtype levels in serum or plasma samples against each of the individual antigen...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Rafael Assis, Aarti Jain, Rie Nakajima, Algis Jasinskas, Saahir Khan, Huw Davies, Laurence Corash, Larry J. Dumont, Kathleen Kelly, Graham Simmons, Mars Stone, Clara Di Germanio, Michael Busch, Philip L. Felgner
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/b90f04eff15f4ad096a3d2b29bf9a651
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:b90f04eff15f4ad096a3d2b29bf9a651
record_format dspace
spelling oai:doaj.org-article:b90f04eff15f4ad096a3d2b29bf9a6512021-12-02T18:15:45ZDistinct SARS-CoV-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray10.1038/s41598-021-87137-72045-2322https://doaj.org/article/b90f04eff15f4ad096a3d2b29bf9a6512021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-87137-7https://doaj.org/toc/2045-2322Abstract A coronavirus antigen microarray (COVAM) was constructed containing 11 SARS-CoV-2, 5 SARS-1, 5 MERS, and 12 seasonal coronavirus recombinant proteins. The array is designed to measure immunoglobulin isotype and subtype levels in serum or plasma samples against each of the individual antigens printed on the array. We probed the COVAM with COVID-19 convalescent plasma (CCP) collected from 99 donors who recovered from a PCR+ confirmed SARS-CoV-2 infection. The results were analyzed using two computational approaches, a generalized linear model (glm) and random forest (RF) prediction model, to classify individual specimens as either Reactive or non-reactive against the SARS-CoV-2 antigens. A training set of 88 pre-COVID-19 specimens (PreCoV) collected in August 2019 and102 positive specimens from SARS-CoV-2 PCR+ confirmed COVID-19 cases was used for these analyses. Results compared with an FDA emergency use authorized (EUA) SARS-CoV2 S1-based total Ig chemiluminescence immunoassay (Ortho Clinical Diagnostics VITROS Anti-SARS-CoV-2 Total, CoV2T) and with a SARS-CoV-2 S1-S2 spike-based pseudovirus micro neutralization assay (SARS-CoV-2 reporter viral particle neutralization titration (RVPNT) showed high concordance between the three assays. Three CCP specimens that were negative by the VITROS CoV2T immunoassay were also negative by both COVAM and the RVPNT assay. Concordance between VITROS CoV2T and COVAM was 96%, VITROS CoV2T and RVPNT 93%, and RVPNT and COVAM 91%. The discordances were all weakly reactive samples near the cutoff threshold of the VITROS CoV2T immunoassay. The multiplex COVAM allows CCP to be grouped according to antibody reactivity patterns against 11 SARS-CoV-2 antigens. Unsupervised K-means analysis, via the gap statistics, as well as hierarchical clustering analysis revealed three main clusters with distinct reactivity intensities and patterns. These patterns were not recapitulated by adjusting the VITROS CoV2T or RVPNT assay thresholds. Plasma classified by COVAM reactivity patterns offers potential to improve CCP therapeutic efficacy CoV2T alone. The use of a SARS-CoV-2 antigen array can qualify CCP for administration as a treatment for acute COVID-19, and interrogate vaccine immunogenicity and performance in preclinical, clinical studies, and routine vaccination to identify antibody responses predictive of protection from infection and disease.Rafael AssisAarti JainRie NakajimaAlgis JasinskasSaahir KhanHuw DaviesLaurence CorashLarry J. DumontKathleen KellyGraham SimmonsMars StoneClara Di GermanioMichael BuschPhilip L. FelgnerNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-12 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Rafael Assis
Aarti Jain
Rie Nakajima
Algis Jasinskas
Saahir Khan
Huw Davies
Laurence Corash
Larry J. Dumont
Kathleen Kelly
Graham Simmons
Mars Stone
Clara Di Germanio
Michael Busch
Philip L. Felgner
Distinct SARS-CoV-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray
description Abstract A coronavirus antigen microarray (COVAM) was constructed containing 11 SARS-CoV-2, 5 SARS-1, 5 MERS, and 12 seasonal coronavirus recombinant proteins. The array is designed to measure immunoglobulin isotype and subtype levels in serum or plasma samples against each of the individual antigens printed on the array. We probed the COVAM with COVID-19 convalescent plasma (CCP) collected from 99 donors who recovered from a PCR+ confirmed SARS-CoV-2 infection. The results were analyzed using two computational approaches, a generalized linear model (glm) and random forest (RF) prediction model, to classify individual specimens as either Reactive or non-reactive against the SARS-CoV-2 antigens. A training set of 88 pre-COVID-19 specimens (PreCoV) collected in August 2019 and102 positive specimens from SARS-CoV-2 PCR+ confirmed COVID-19 cases was used for these analyses. Results compared with an FDA emergency use authorized (EUA) SARS-CoV2 S1-based total Ig chemiluminescence immunoassay (Ortho Clinical Diagnostics VITROS Anti-SARS-CoV-2 Total, CoV2T) and with a SARS-CoV-2 S1-S2 spike-based pseudovirus micro neutralization assay (SARS-CoV-2 reporter viral particle neutralization titration (RVPNT) showed high concordance between the three assays. Three CCP specimens that were negative by the VITROS CoV2T immunoassay were also negative by both COVAM and the RVPNT assay. Concordance between VITROS CoV2T and COVAM was 96%, VITROS CoV2T and RVPNT 93%, and RVPNT and COVAM 91%. The discordances were all weakly reactive samples near the cutoff threshold of the VITROS CoV2T immunoassay. The multiplex COVAM allows CCP to be grouped according to antibody reactivity patterns against 11 SARS-CoV-2 antigens. Unsupervised K-means analysis, via the gap statistics, as well as hierarchical clustering analysis revealed three main clusters with distinct reactivity intensities and patterns. These patterns were not recapitulated by adjusting the VITROS CoV2T or RVPNT assay thresholds. Plasma classified by COVAM reactivity patterns offers potential to improve CCP therapeutic efficacy CoV2T alone. The use of a SARS-CoV-2 antigen array can qualify CCP for administration as a treatment for acute COVID-19, and interrogate vaccine immunogenicity and performance in preclinical, clinical studies, and routine vaccination to identify antibody responses predictive of protection from infection and disease.
format article
author Rafael Assis
Aarti Jain
Rie Nakajima
Algis Jasinskas
Saahir Khan
Huw Davies
Laurence Corash
Larry J. Dumont
Kathleen Kelly
Graham Simmons
Mars Stone
Clara Di Germanio
Michael Busch
Philip L. Felgner
author_facet Rafael Assis
Aarti Jain
Rie Nakajima
Algis Jasinskas
Saahir Khan
Huw Davies
Laurence Corash
Larry J. Dumont
Kathleen Kelly
Graham Simmons
Mars Stone
Clara Di Germanio
Michael Busch
Philip L. Felgner
author_sort Rafael Assis
title Distinct SARS-CoV-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray
title_short Distinct SARS-CoV-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray
title_full Distinct SARS-CoV-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray
title_fullStr Distinct SARS-CoV-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray
title_full_unstemmed Distinct SARS-CoV-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray
title_sort distinct sars-cov-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/b90f04eff15f4ad096a3d2b29bf9a651
work_keys_str_mv AT rafaelassis distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT aartijain distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT rienakajima distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT algisjasinskas distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT saahirkhan distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT huwdavies distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT laurencecorash distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT larryjdumont distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT kathleenkelly distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT grahamsimmons distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT marsstone distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT claradigermanio distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT michaelbusch distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
AT philiplfelgner distinctsarscov2antibodyreactivitypatternsincoronavirusconvalescentplasmarevealedbyacoronavirusantigenmicroarray
_version_ 1718378356276199424