Two-Year Comparative Outcomes of First- and Second-Generation Trabecular Micro-Bypass Stents with Cataract Surgery

Ricardo Augusto Paletta Guedes,1 Daniela Marcelo Gravina,1 Vanessa Maria Paletta Guedes,1 Alfredo Chaoubah2 1Glaucoma Department, Paletta Guedes Eye Institute, Juiz de Fora, MG, Brazil; 2Statistics Department, Federal University of Juiz De Fora, Juiz de Fora, MG, BrazilCorrespondence: Ricardo August...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Paletta Guedes RA, Gravina DM, Paletta Guedes VM, Chaoubah A
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2021
Materias:
Acceso en línea:https://doaj.org/article/b9bc18fa39be401a9f6039c831194d77
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Ricardo Augusto Paletta Guedes,1 Daniela Marcelo Gravina,1 Vanessa Maria Paletta Guedes,1 Alfredo Chaoubah2 1Glaucoma Department, Paletta Guedes Eye Institute, Juiz de Fora, MG, Brazil; 2Statistics Department, Federal University of Juiz De Fora, Juiz de Fora, MG, BrazilCorrespondence: Ricardo Augusto Paletta GuedesGlaucoma Department, Paletta Guedes Eye Institute, 79, Oscar Vidal streeet, Juiz de Fora, MG, 36010-060, BrazilTel: +55 32 3213-1927Email palettaguedes@yahoo.comIntroduction: This retrospective comparative study assessed real-world effectiveness and safety of first-generation (iStent®) and second-generation (iStent inject®) trabecular micro-bypass stents with cataract surgery in patients with open-angle glaucoma (OAG).Material and Methods: Through a 24-month postoperative follow-up, the effectiveness was quantified by intraocular pressure (IOP) reduction; mean glaucoma medication reduction; proportional analysis of eyes meeting IOP cutoffs (< 18, < 15, < 12 mmHg) either with or without medications; and proportional analysis of medication burden. Safety measures included visual acuity, adverse events, and secondary surgery.Results: A total of 82 consecutive eyes (39 iStent, 43 iStent inject) with a 24-month follow-up were analyzed. Most eyes (74.4%) had primary open-angle glaucoma, with the remainder having pseudoexfoliative or pigmentary glaucoma; all eyes had mild-to-moderate disease. At 24 months postoperative, the mean IOP was lower, and the percent reduction from baseline was greater, in iStent inject eyes (26.0% reduction, 17.7mmHg to 13.1mmHg) than in iStent eyes (9.8% reduction, 16.4mmHg to 14.8mmHg) (between-groups comparison, p=0.019). Within each group, the postoperative IOP reduction was greater in eyes with higher baseline IOP (p< 0.001). Medication burden decreased significantly in both groups, from 1.74 to 0.51 mean medications for iStent (70.7% reduction, p< 0.0001), and 2.19 to 0.65 for iStent inject (70.3% reduction, p< 0.0001). Both groups exhibited excellent safety.Conclusion: iStent or iStent inject with phacoemulsification produced significant IOP and medication reductions, with effects enduring for two years. IOP reductions were greater for iStent inject than for iStent. Within each group, higher preoperative IOP was associated with greater postoperative IOP reduction.Keywords: iStent, iStent inject, trabecular micro-bypass, micro-invasive, MIGS