APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT
Introduction. Determination of power quality indices in high-voltage power grids allows to find the reasons for the deterioration of the power quality. The relevant national and International Standards for power quality contain relevant norms of quality indices and requirements for their accuracy me...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN RU UK |
Publicado: |
National Technical University "Kharkiv Polytechnic Institute"
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/b9f2e7e9dcb64a8686dcabfabc36883c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:b9f2e7e9dcb64a8686dcabfabc36883c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:b9f2e7e9dcb64a8686dcabfabc36883c2021-12-02T14:56:54ZAPPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT10.20998/2074-272X.2017.6.082074-272X2309-3404https://doaj.org/article/b9f2e7e9dcb64a8686dcabfabc36883c2017-12-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2017.6.08/110439https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Introduction. Determination of power quality indices in high-voltage power grids allows to find the reasons for the deterioration of the power quality. The relevant national and International Standards for power quality contain relevant norms of quality indices and requirements for their accuracy measurement. Problem. The most complicated part in the process of measuring the power quality indices at high voltage is the selection of the corresponding high-voltage scale voltage converters. Therefore, comparing the requirements of IEC 61000-4-30 to high voltage scale voltage converters is an important task. Goal. Analysis of the International Standard IEC 61000-4-30 requirements feasibility for measuring the indices of power quality in high-voltage electrical networks using different types of high-voltage scale voltage converters. Methodology. Comparison of the requirements of IEC 61000-4-30 Standard to high-voltage scale voltage converters, when measuring power quality indices, with the characteristics of high voltage electromagnetic transformers used in Ukraine, and with promising developments of high-voltage converters of other types. Results. It is shown in the study that in order to fulfill some of the requirements for class A of IEC 61000-4-30, the characteristics of electromagnetic voltage transformers should be determined in the substation conditions using mobile calibration high-voltage laboratories. To meet all the requirements for Class A IEC 61000-4-30, it is recommended to use broadband high-voltage dividers of resistive-capacitive type. Originality. In study it is shown firstly that all the requirements of the IEC 61000-4-30 Standard for high-voltage scale voltage converters can be performed on the basis of the use of broadband resistive-capacitive damped voltage dividers. Practical value. Expositions of specific types of resistive-capacitive high-voltage dividers are presented, their parameters are confirmed by the results of state metrological certification.Y. L. AnokhinV. O. BrzhezitskyYa. O. HaranI. M. MasliuchenkoO. P. ProtsenkoYe. O. TrotsenkoNational Technical University "Kharkiv Polytechnic Institute"articlepower quality indiceshigh voltageelectromagnetic transformersvoltage dividersElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 6, Pp 53-59 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN RU UK |
topic |
power quality indices high voltage electromagnetic transformers voltage dividers Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
power quality indices high voltage electromagnetic transformers voltage dividers Electrical engineering. Electronics. Nuclear engineering TK1-9971 Y. L. Anokhin V. O. Brzhezitsky Ya. O. Haran I. M. Masliuchenko O. P. Protsenko Ye. O. Trotsenko APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT |
description |
Introduction. Determination of power quality indices in high-voltage power grids allows to find the reasons for the deterioration of the power quality. The relevant national and International Standards for power quality contain relevant norms of quality indices and requirements for their accuracy measurement. Problem. The most complicated part in the process of measuring the power quality indices at high voltage is the selection of the corresponding high-voltage scale voltage converters. Therefore, comparing the requirements of IEC 61000-4-30 to high voltage scale voltage converters is an important task. Goal. Analysis of the International Standard IEC 61000-4-30 requirements feasibility for measuring the indices of power quality in high-voltage electrical networks using different types of high-voltage scale voltage converters. Methodology. Comparison of the requirements of IEC 61000-4-30 Standard to high-voltage scale voltage converters, when measuring power quality indices, with the characteristics of high voltage electromagnetic transformers used in Ukraine, and with promising developments of high-voltage converters of other types. Results. It is shown in the study that in order to fulfill some of the requirements for class A of IEC 61000-4-30, the characteristics of electromagnetic voltage transformers should be determined in the substation conditions using mobile calibration high-voltage laboratories. To meet all the requirements for Class A IEC 61000-4-30, it is recommended to use broadband high-voltage dividers of resistive-capacitive type. Originality. In study it is shown firstly that all the requirements of the IEC 61000-4-30 Standard for high-voltage scale voltage converters can be performed on the basis of the use of broadband resistive-capacitive damped voltage dividers. Practical value. Expositions of specific types of resistive-capacitive high-voltage dividers are presented, their parameters are confirmed by the results of state metrological certification. |
format |
article |
author |
Y. L. Anokhin V. O. Brzhezitsky Ya. O. Haran I. M. Masliuchenko O. P. Protsenko Ye. O. Trotsenko |
author_facet |
Y. L. Anokhin V. O. Brzhezitsky Ya. O. Haran I. M. Masliuchenko O. P. Protsenko Ye. O. Trotsenko |
author_sort |
Y. L. Anokhin |
title |
APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT |
title_short |
APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT |
title_full |
APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT |
title_fullStr |
APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT |
title_full_unstemmed |
APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT |
title_sort |
application of high voltage dividers for power quality indices measurement |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
publishDate |
2017 |
url |
https://doaj.org/article/b9f2e7e9dcb64a8686dcabfabc36883c |
work_keys_str_mv |
AT ylanokhin applicationofhighvoltagedividersforpowerqualityindicesmeasurement AT vobrzhezitsky applicationofhighvoltagedividersforpowerqualityindicesmeasurement AT yaoharan applicationofhighvoltagedividersforpowerqualityindicesmeasurement AT immasliuchenko applicationofhighvoltagedividersforpowerqualityindicesmeasurement AT opprotsenko applicationofhighvoltagedividersforpowerqualityindicesmeasurement AT yeotrotsenko applicationofhighvoltagedividersforpowerqualityindicesmeasurement |
_version_ |
1718389345354776576 |