Comparison of The WHO Formula A and B Handrub Effectiveness Against Staphylococcus aureus : Study In Diponegoro National Hospital Emergency Room, High Care Unit, and Storeroom Based on prEN12054 Modification

Introduction: Good implementation of hand hygiene and the availability of cheap, affordable, and effective hand rub can prevent healthcare-associated infection. WHO has issued hand rub formulations that are easily self-produced, effective, and affordable.  Objective: This study compares the differe...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yohanes Daniel, Endang Sri Lestari, V. Rizke Ciptaningtyas
Formato: article
Lenguaje:EN
Publicado: Universitas Sultan Agung Semarang 2018
Materias:
Acceso en línea:https://doaj.org/article/ba5b57b9fa174bb8b1042857c4e9916d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:ba5b57b9fa174bb8b1042857c4e9916d
record_format dspace
spelling oai:doaj.org-article:ba5b57b9fa174bb8b1042857c4e9916d2021-11-25T13:16:08ZComparison of The WHO Formula A and B Handrub Effectiveness Against Staphylococcus aureus : Study In Diponegoro National Hospital Emergency Room, High Care Unit, and Storeroom Based on prEN12054 Modification2085-15452339-093X10.30659/sainsmed.v9i2.2639https://doaj.org/article/ba5b57b9fa174bb8b1042857c4e9916d2018-11-01T00:00:00Zhttp://jurnal.unissula.ac.id/index.php/sainsmedika/article/view/2639https://doaj.org/toc/2085-1545https://doaj.org/toc/2339-093XIntroduction: Good implementation of hand hygiene and the availability of cheap, affordable, and effective hand rub can prevent healthcare-associated infection. WHO has issued hand rub formulations that are easily self-produced, effective, and affordable.  Objective: This study compares the difference between handrub’s effectiveness stored in National Hospital Diponegoro University ER, HCU, and storeroom for 2 and 10 weeks. Methods: This study was an experimental study with pretest posttest randomized group design. The effectiveness of hand rub measured by prEN12054 in cfu/ml.  Results: There was no significant difference between efficacy of WHO formula A and B (p=0.458). In the Mann-Whitney test there was no difference between the effectiveness of WHO A and B formulas before storage (p = 0.567), after being stored for two weeks (p=1.000), and ten weeks (p=0.539). In the Kruskal-Wallis test, there was no difference in the effectiveness of the WHO A formula in three sites at weeks 0, 2 and 10 (p = 0.275, 0.584, 0.116), there was no difference in the effectiveness of the WHO B formula in three sites at week 0, the 2nd and 10th (p = 0.289.; p = 0.584, p = 1.000). Conclusion: No significant differences were found on the effectiveness of the WHO A and B formulas. There was no significant difference in the effectiveness of WHO A or B formulas stored in three sites. There were no significant differences in the effectiveness of WHO A or B formulas, before and after being stored for two and ten weeks in three sites.Yohanes DanielEndang Sri LestariV. Rizke CiptaningtyasUniversitas Sultan Agung Semarangarticlealcohol-based hand rubwho formulahand hygienepren12054Medicine (General)R5-920ENSains Medika, Vol 9, Iss 2, Pp 50-55 (2018)
institution DOAJ
collection DOAJ
language EN
topic alcohol-based hand rub
who formula
hand hygiene
pren12054
Medicine (General)
R5-920
spellingShingle alcohol-based hand rub
who formula
hand hygiene
pren12054
Medicine (General)
R5-920
Yohanes Daniel
Endang Sri Lestari
V. Rizke Ciptaningtyas
Comparison of The WHO Formula A and B Handrub Effectiveness Against Staphylococcus aureus : Study In Diponegoro National Hospital Emergency Room, High Care Unit, and Storeroom Based on prEN12054 Modification
description Introduction: Good implementation of hand hygiene and the availability of cheap, affordable, and effective hand rub can prevent healthcare-associated infection. WHO has issued hand rub formulations that are easily self-produced, effective, and affordable.  Objective: This study compares the difference between handrub’s effectiveness stored in National Hospital Diponegoro University ER, HCU, and storeroom for 2 and 10 weeks. Methods: This study was an experimental study with pretest posttest randomized group design. The effectiveness of hand rub measured by prEN12054 in cfu/ml.  Results: There was no significant difference between efficacy of WHO formula A and B (p=0.458). In the Mann-Whitney test there was no difference between the effectiveness of WHO A and B formulas before storage (p = 0.567), after being stored for two weeks (p=1.000), and ten weeks (p=0.539). In the Kruskal-Wallis test, there was no difference in the effectiveness of the WHO A formula in three sites at weeks 0, 2 and 10 (p = 0.275, 0.584, 0.116), there was no difference in the effectiveness of the WHO B formula in three sites at week 0, the 2nd and 10th (p = 0.289.; p = 0.584, p = 1.000). Conclusion: No significant differences were found on the effectiveness of the WHO A and B formulas. There was no significant difference in the effectiveness of WHO A or B formulas stored in three sites. There were no significant differences in the effectiveness of WHO A or B formulas, before and after being stored for two and ten weeks in three sites.
format article
author Yohanes Daniel
Endang Sri Lestari
V. Rizke Ciptaningtyas
author_facet Yohanes Daniel
Endang Sri Lestari
V. Rizke Ciptaningtyas
author_sort Yohanes Daniel
title Comparison of The WHO Formula A and B Handrub Effectiveness Against Staphylococcus aureus : Study In Diponegoro National Hospital Emergency Room, High Care Unit, and Storeroom Based on prEN12054 Modification
title_short Comparison of The WHO Formula A and B Handrub Effectiveness Against Staphylococcus aureus : Study In Diponegoro National Hospital Emergency Room, High Care Unit, and Storeroom Based on prEN12054 Modification
title_full Comparison of The WHO Formula A and B Handrub Effectiveness Against Staphylococcus aureus : Study In Diponegoro National Hospital Emergency Room, High Care Unit, and Storeroom Based on prEN12054 Modification
title_fullStr Comparison of The WHO Formula A and B Handrub Effectiveness Against Staphylococcus aureus : Study In Diponegoro National Hospital Emergency Room, High Care Unit, and Storeroom Based on prEN12054 Modification
title_full_unstemmed Comparison of The WHO Formula A and B Handrub Effectiveness Against Staphylococcus aureus : Study In Diponegoro National Hospital Emergency Room, High Care Unit, and Storeroom Based on prEN12054 Modification
title_sort comparison of the who formula a and b handrub effectiveness against staphylococcus aureus : study in diponegoro national hospital emergency room, high care unit, and storeroom based on pren12054 modification
publisher Universitas Sultan Agung Semarang
publishDate 2018
url https://doaj.org/article/ba5b57b9fa174bb8b1042857c4e9916d
work_keys_str_mv AT yohanesdaniel comparisonofthewhoformulaaandbhandrubeffectivenessagainststaphylococcusaureusstudyindiponegoronationalhospitalemergencyroomhighcareunitandstoreroombasedonpren12054modification
AT endangsrilestari comparisonofthewhoformulaaandbhandrubeffectivenessagainststaphylococcusaureusstudyindiponegoronationalhospitalemergencyroomhighcareunitandstoreroombasedonpren12054modification
AT vrizkeciptaningtyas comparisonofthewhoformulaaandbhandrubeffectivenessagainststaphylococcusaureusstudyindiponegoronationalhospitalemergencyroomhighcareunitandstoreroombasedonpren12054modification
_version_ 1718413522852904960