Segmentation and removal of fibrovascular membranes with high-speed 23 G transconjunctival sutureless vitrectomy, in severe proliferative diabetic retinopathy

Erkan Celik,1 Ozkan Sever,2 Fatih Horozoglu,2 Ates Yanyali3 1Sakarya University Medical Education and Research Hospital, Sakarya, 2Namik Kemal University, School of Medicine, Tekirdag, 3Haydarpasa Numune Medical Education and Research Hospital, Istanbul, Turkey Aim: To evaluate the effectiveness a...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Celik E, Sever O, Horozoglu F, Yanyalı A
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://doaj.org/article/ba77c21c7c264829ab581f07e8a914c1
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Erkan Celik,1 Ozkan Sever,2 Fatih Horozoglu,2 Ates Yanyali3 1Sakarya University Medical Education and Research Hospital, Sakarya, 2Namik Kemal University, School of Medicine, Tekirdag, 3Haydarpasa Numune Medical Education and Research Hospital, Istanbul, Turkey Aim: To evaluate the effectiveness and safety of high-speed (5,000 cuts per minute) 23 G transconjunctival sutureless vitrectomy (TSV) in severe diabetic fibrovascular proliferation (DFVP). Patients and methods: In this retrospective consecutive case series, patients who underwent 23 G TSV for severe DFVP between October 2011 and March 2014 at our institution were evaluated. 23 G TSV was performed with a high-speed (5,000 cuts per minute) cutter without a chandelier light. Results: The mean follow-up period was 8 months (range: 4–23 months). Of the 27 eyes of 27 patients, 14 eyes (52%) underwent concomitant phacoemulsification with posterior chamber intraocular lens implantation, nine eyes (33%) were pseudophakic, and four eyes were phakic (15%). DFVP was removed with ease in all, and visual acuity was improved in 18 (67%) eyes. Iatrogenic retinal tear was observed in four eyes (15%) and treated successfully during surgery. Suture placement to a single sclerotomy was performed in eight eyes (30%). Postoperative intraocular hemorrhage was observed in five eyes (18%). Cataract formation was observed in two of the four phakic eyes. Three (11%) patients had postoperative intraocular pressure rise. Postoperative hypotony (≤6 mmHg) and endophthalmitis were not observed in any eye. Conclusion: The segmentation and removal of fibrovascular membranes with high-speed 23 G TSV seems to be a safe and easy method in severe diabetic eye disease. Keywords: diabetic fibrovascular proliferation, transconjunctival sutureless vitrectomy, high speed