Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia

This study investigated twenty-two (22) state elementary schools, regarding daylight annual illuminance in the classrooms, using climate-based daylight modelling (CBDM) metrics. This is due to the missing information on the annual daylight performance inside the classroom in Indonesia. Over 250 clas...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Atthaillah, Rizki A. Mangkuto, M. Donny Koerniawan, F.X. Nugroho Soelami
Formato: article
Lenguaje:EN
Publicado: Tamkang University Press 2021
Materias:
Acceso en línea:https://doaj.org/article/baf1eadba93f4d1c8cd106d67ed41e89
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:baf1eadba93f4d1c8cd106d67ed41e89
record_format dspace
spelling oai:doaj.org-article:baf1eadba93f4d1c8cd106d67ed41e892021-11-23T14:20:40ZDaylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia10.6180/jase.202202_25(1).00132708-99672708-9975https://doaj.org/article/baf1eadba93f4d1c8cd106d67ed41e892021-11-01T00:00:00Zhttp://jase.tku.edu.tw/articles/jase-202202-25-1-0013https://doaj.org/toc/2708-9967https://doaj.org/toc/2708-9975This study investigated twenty-two (22) state elementary schools, regarding daylight annual illuminance in the classrooms, using climate-based daylight modelling (CBDM) metrics. This is due to the missing information on the annual daylight performance inside the classroom in Indonesia. Over 250 classrooms were assessed using Rhinoceros and Grasshopper computational platforms. Furthermore, the Days simulation engine was employed through the advantage of Ladybug tools to connect and automate the simulation workflow parametrically. Since there were no prior studies using CBDM metrics for daylight assessment of classrooms in the Indonesian context, the illuminance range from 250 to 750 lux was taken as the target for the annual useful daylight illuminance (UDI), as suggested in the Indonesian daylighting standard. The result shows 35 classrooms under the good daylight performance,171 classrooms insufficient category and 50 others under unsatisfactory of annual illuminance. The most sensitive contributors are both corridor and back shading depth with Spearman correlation of -0.70 and -0.76 respectively. The strong sensitive variables both have p-values lower than 0.05 which indicates statistical significance for the model.AtthaillahRizki A. MangkutoM. Donny KoerniawanF.X. Nugroho SoelamiTamkang University Pressarticledaylightingelementary school classroomsclimate based daylight modelingcomputer simulationannual illuminancesEngineering (General). Civil engineering (General)TA1-2040Chemical engineeringTP155-156PhysicsQC1-999ENJournal of Applied Science and Engineering, Vol 25, Iss 1, Pp 129-139 (2021)
institution DOAJ
collection DOAJ
language EN
topic daylighting
elementary school classrooms
climate based daylight modeling
computer simulation
annual illuminances
Engineering (General). Civil engineering (General)
TA1-2040
Chemical engineering
TP155-156
Physics
QC1-999
spellingShingle daylighting
elementary school classrooms
climate based daylight modeling
computer simulation
annual illuminances
Engineering (General). Civil engineering (General)
TA1-2040
Chemical engineering
TP155-156
Physics
QC1-999
Atthaillah
Rizki A. Mangkuto
M. Donny Koerniawan
F.X. Nugroho Soelami
Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia
description This study investigated twenty-two (22) state elementary schools, regarding daylight annual illuminance in the classrooms, using climate-based daylight modelling (CBDM) metrics. This is due to the missing information on the annual daylight performance inside the classroom in Indonesia. Over 250 classrooms were assessed using Rhinoceros and Grasshopper computational platforms. Furthermore, the Days simulation engine was employed through the advantage of Ladybug tools to connect and automate the simulation workflow parametrically. Since there were no prior studies using CBDM metrics for daylight assessment of classrooms in the Indonesian context, the illuminance range from 250 to 750 lux was taken as the target for the annual useful daylight illuminance (UDI), as suggested in the Indonesian daylighting standard. The result shows 35 classrooms under the good daylight performance,171 classrooms insufficient category and 50 others under unsatisfactory of annual illuminance. The most sensitive contributors are both corridor and back shading depth with Spearman correlation of -0.70 and -0.76 respectively. The strong sensitive variables both have p-values lower than 0.05 which indicates statistical significance for the model.
format article
author Atthaillah
Rizki A. Mangkuto
M. Donny Koerniawan
F.X. Nugroho Soelami
author_facet Atthaillah
Rizki A. Mangkuto
M. Donny Koerniawan
F.X. Nugroho Soelami
author_sort Atthaillah
title Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia
title_short Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia
title_full Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia
title_fullStr Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia
title_full_unstemmed Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia
title_sort daylight annual illuminance investigation in elementary school classrooms for the tropic of lhokseumawe, indonesia
publisher Tamkang University Press
publishDate 2021
url https://doaj.org/article/baf1eadba93f4d1c8cd106d67ed41e89
work_keys_str_mv AT atthaillah daylightannualilluminanceinvestigationinelementaryschoolclassroomsforthetropicoflhokseumaweindonesia
AT rizkiamangkuto daylightannualilluminanceinvestigationinelementaryschoolclassroomsforthetropicoflhokseumaweindonesia
AT mdonnykoerniawan daylightannualilluminanceinvestigationinelementaryschoolclassroomsforthetropicoflhokseumaweindonesia
AT fxnugrohosoelami daylightannualilluminanceinvestigationinelementaryschoolclassroomsforthetropicoflhokseumaweindonesia
_version_ 1718416724746829824