Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia
This study investigated twenty-two (22) state elementary schools, regarding daylight annual illuminance in the classrooms, using climate-based daylight modelling (CBDM) metrics. This is due to the missing information on the annual daylight performance inside the classroom in Indonesia. Over 250 clas...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Tamkang University Press
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/baf1eadba93f4d1c8cd106d67ed41e89 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:baf1eadba93f4d1c8cd106d67ed41e89 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:baf1eadba93f4d1c8cd106d67ed41e892021-11-23T14:20:40ZDaylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia10.6180/jase.202202_25(1).00132708-99672708-9975https://doaj.org/article/baf1eadba93f4d1c8cd106d67ed41e892021-11-01T00:00:00Zhttp://jase.tku.edu.tw/articles/jase-202202-25-1-0013https://doaj.org/toc/2708-9967https://doaj.org/toc/2708-9975This study investigated twenty-two (22) state elementary schools, regarding daylight annual illuminance in the classrooms, using climate-based daylight modelling (CBDM) metrics. This is due to the missing information on the annual daylight performance inside the classroom in Indonesia. Over 250 classrooms were assessed using Rhinoceros and Grasshopper computational platforms. Furthermore, the Days simulation engine was employed through the advantage of Ladybug tools to connect and automate the simulation workflow parametrically. Since there were no prior studies using CBDM metrics for daylight assessment of classrooms in the Indonesian context, the illuminance range from 250 to 750 lux was taken as the target for the annual useful daylight illuminance (UDI), as suggested in the Indonesian daylighting standard. The result shows 35 classrooms under the good daylight performance,171 classrooms insufficient category and 50 others under unsatisfactory of annual illuminance. The most sensitive contributors are both corridor and back shading depth with Spearman correlation of -0.70 and -0.76 respectively. The strong sensitive variables both have p-values lower than 0.05 which indicates statistical significance for the model.AtthaillahRizki A. MangkutoM. Donny KoerniawanF.X. Nugroho SoelamiTamkang University Pressarticledaylightingelementary school classroomsclimate based daylight modelingcomputer simulationannual illuminancesEngineering (General). Civil engineering (General)TA1-2040Chemical engineeringTP155-156PhysicsQC1-999ENJournal of Applied Science and Engineering, Vol 25, Iss 1, Pp 129-139 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
daylighting elementary school classrooms climate based daylight modeling computer simulation annual illuminances Engineering (General). Civil engineering (General) TA1-2040 Chemical engineering TP155-156 Physics QC1-999 |
spellingShingle |
daylighting elementary school classrooms climate based daylight modeling computer simulation annual illuminances Engineering (General). Civil engineering (General) TA1-2040 Chemical engineering TP155-156 Physics QC1-999 Atthaillah Rizki A. Mangkuto M. Donny Koerniawan F.X. Nugroho Soelami Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia |
description |
This study investigated twenty-two (22) state elementary schools, regarding daylight annual illuminance in the classrooms, using climate-based daylight modelling (CBDM) metrics. This is due to the missing information on the annual daylight performance inside the classroom in Indonesia. Over 250 classrooms were assessed using Rhinoceros and Grasshopper computational platforms. Furthermore, the Days simulation engine was employed through the advantage of Ladybug tools to connect and automate the simulation workflow parametrically. Since there were no prior studies using CBDM metrics for daylight assessment of classrooms in the Indonesian context, the illuminance range from 250 to 750 lux was taken as the target for the annual useful daylight illuminance (UDI), as suggested in the Indonesian daylighting standard. The result shows 35 classrooms under the good daylight performance,171 classrooms insufficient category and 50 others under unsatisfactory of annual illuminance. The most sensitive contributors are both corridor and back shading depth with Spearman correlation of -0.70 and -0.76 respectively. The strong sensitive variables both have p-values lower than 0.05 which indicates statistical significance for the model. |
format |
article |
author |
Atthaillah Rizki A. Mangkuto M. Donny Koerniawan F.X. Nugroho Soelami |
author_facet |
Atthaillah Rizki A. Mangkuto M. Donny Koerniawan F.X. Nugroho Soelami |
author_sort |
Atthaillah |
title |
Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia |
title_short |
Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia |
title_full |
Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia |
title_fullStr |
Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia |
title_full_unstemmed |
Daylight Annual Illuminance Investigation in Elementary School Classrooms for the Tropic of Lhokseumawe, Indonesia |
title_sort |
daylight annual illuminance investigation in elementary school classrooms for the tropic of lhokseumawe, indonesia |
publisher |
Tamkang University Press |
publishDate |
2021 |
url |
https://doaj.org/article/baf1eadba93f4d1c8cd106d67ed41e89 |
work_keys_str_mv |
AT atthaillah daylightannualilluminanceinvestigationinelementaryschoolclassroomsforthetropicoflhokseumaweindonesia AT rizkiamangkuto daylightannualilluminanceinvestigationinelementaryschoolclassroomsforthetropicoflhokseumaweindonesia AT mdonnykoerniawan daylightannualilluminanceinvestigationinelementaryschoolclassroomsforthetropicoflhokseumaweindonesia AT fxnugrohosoelami daylightannualilluminanceinvestigationinelementaryschoolclassroomsforthetropicoflhokseumaweindonesia |
_version_ |
1718416724746829824 |