Occupational eye dose in interventional cardiology procedures

Abstract It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yoshihiro Haga, Koichi Chida, Yuji Kaga, Masahiro Sota, Taiichiro Meguro, Masayuki Zuguchi
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/bb15d6298566410e90acba444258448d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:bb15d6298566410e90acba444258448d
record_format dspace
spelling oai:doaj.org-article:bb15d6298566410e90acba444258448d2021-12-02T11:40:59ZOccupational eye dose in interventional cardiology procedures10.1038/s41598-017-00556-32045-2322https://doaj.org/article/bb15d6298566410e90acba444258448d2017-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-00556-3https://doaj.org/toc/2045-2322Abstract It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRISTM. We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R2 = 0.93 and R2 = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose.Yoshihiro HagaKoichi ChidaYuji KagaMasahiro SotaTaiichiro MeguroMasayuki ZuguchiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-7 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Yoshihiro Haga
Koichi Chida
Yuji Kaga
Masahiro Sota
Taiichiro Meguro
Masayuki Zuguchi
Occupational eye dose in interventional cardiology procedures
description Abstract It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRISTM. We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R2 = 0.93 and R2 = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose.
format article
author Yoshihiro Haga
Koichi Chida
Yuji Kaga
Masahiro Sota
Taiichiro Meguro
Masayuki Zuguchi
author_facet Yoshihiro Haga
Koichi Chida
Yuji Kaga
Masahiro Sota
Taiichiro Meguro
Masayuki Zuguchi
author_sort Yoshihiro Haga
title Occupational eye dose in interventional cardiology procedures
title_short Occupational eye dose in interventional cardiology procedures
title_full Occupational eye dose in interventional cardiology procedures
title_fullStr Occupational eye dose in interventional cardiology procedures
title_full_unstemmed Occupational eye dose in interventional cardiology procedures
title_sort occupational eye dose in interventional cardiology procedures
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/bb15d6298566410e90acba444258448d
work_keys_str_mv AT yoshihirohaga occupationaleyedoseininterventionalcardiologyprocedures
AT koichichida occupationaleyedoseininterventionalcardiologyprocedures
AT yujikaga occupationaleyedoseininterventionalcardiologyprocedures
AT masahirosota occupationaleyedoseininterventionalcardiologyprocedures
AT taiichiromeguro occupationaleyedoseininterventionalcardiologyprocedures
AT masayukizuguchi occupationaleyedoseininterventionalcardiologyprocedures
_version_ 1718395482142670848