Occupational eye dose in interventional cardiology procedures
Abstract It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/bb15d6298566410e90acba444258448d |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:bb15d6298566410e90acba444258448d |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:bb15d6298566410e90acba444258448d2021-12-02T11:40:59ZOccupational eye dose in interventional cardiology procedures10.1038/s41598-017-00556-32045-2322https://doaj.org/article/bb15d6298566410e90acba444258448d2017-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-00556-3https://doaj.org/toc/2045-2322Abstract It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRISTM. We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R2 = 0.93 and R2 = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose.Yoshihiro HagaKoichi ChidaYuji KagaMasahiro SotaTaiichiro MeguroMasayuki ZuguchiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-7 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Yoshihiro Haga Koichi Chida Yuji Kaga Masahiro Sota Taiichiro Meguro Masayuki Zuguchi Occupational eye dose in interventional cardiology procedures |
description |
Abstract It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRISTM. We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R2 = 0.93 and R2 = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose. |
format |
article |
author |
Yoshihiro Haga Koichi Chida Yuji Kaga Masahiro Sota Taiichiro Meguro Masayuki Zuguchi |
author_facet |
Yoshihiro Haga Koichi Chida Yuji Kaga Masahiro Sota Taiichiro Meguro Masayuki Zuguchi |
author_sort |
Yoshihiro Haga |
title |
Occupational eye dose in interventional cardiology procedures |
title_short |
Occupational eye dose in interventional cardiology procedures |
title_full |
Occupational eye dose in interventional cardiology procedures |
title_fullStr |
Occupational eye dose in interventional cardiology procedures |
title_full_unstemmed |
Occupational eye dose in interventional cardiology procedures |
title_sort |
occupational eye dose in interventional cardiology procedures |
publisher |
Nature Portfolio |
publishDate |
2017 |
url |
https://doaj.org/article/bb15d6298566410e90acba444258448d |
work_keys_str_mv |
AT yoshihirohaga occupationaleyedoseininterventionalcardiologyprocedures AT koichichida occupationaleyedoseininterventionalcardiologyprocedures AT yujikaga occupationaleyedoseininterventionalcardiologyprocedures AT masahirosota occupationaleyedoseininterventionalcardiologyprocedures AT taiichiromeguro occupationaleyedoseininterventionalcardiologyprocedures AT masayukizuguchi occupationaleyedoseininterventionalcardiologyprocedures |
_version_ |
1718395482142670848 |