Abstract Background The accurate and independent measurement of blood pressure (BP) by patients is essential for home BP monitoring (HBPM) and determining the quality of hypertension (HTN) control. This study aimed to evaluate the BP self-measurement techniques of hypertensive patients and their acc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Katarzyna Nessler, Anna Krztoń-Królewiecka, Anna Suska, Mitchell R. Mann, Michał B. Nessler, Adam Windak
Formato: article
Lenguaje:EN
Publicado: BMC 2021
Materias:
Acceso en línea:https://doaj.org/article/bb2d82801ffd4d93a381477466c746b8
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Abstract Background The accurate and independent measurement of blood pressure (BP) by patients is essential for home BP monitoring (HBPM) and determining the quality of hypertension (HTN) control. This study aimed to evaluate the BP self-measurement techniques of hypertensive patients and their accuracy in accordance with established guidelines. We sought to identify the common errors that patients make and suggest improvements that can be implemented in the primary healthcare setting to increase the reliability of HBPM conducted by hypertensive patients. Methods One hundred patients diagnosed with HTN completed a questionnaire inquiring about their health and demographic data and BP monitoring practices. Patients were then observed and filmed while measuring their BP on their own devices in five primary healthcare centres in Kraków, Poland. The correctness of their techniques was assessed in accordance with the European Society of Hypertension guidelines on HBPM. Results Only 3% of patients measured their BP without error; 60% made three or more errors. The most frequent error, made by 76% of subjects, was incorrect sphygmomanometer cuff placement (above or below heart level, or/and the indicator mark was not aligned with the brachial artery). Regarding patients’ previous instruction for the correct use of their devices, 36% of patients referred to their monitor’s user manual, 22% did not receive any prior assistance, and only 29% were adequately counselled by physicians on how to measure their BP correctly. Conclusions Our findings suggest that primary healthcare physicians and their personnel often do not adequately instruct patients on how to measure their BP correctly. Therefore, healthcare systems must provide patients with more adequate training and reference materials on the best practices of BP monitoring.