Influence of Particle Composition and Size on the Accuracy of Low Cost PM Sensors: Findings From Field Campaigns

In the last decade, many low-cost monitoring sensors and sensor-networks have been used as an alternative air quality assessment method. It is also well known that these low cost monitors have calibration, accuracy and long term variation problems which require various calibration techniques. In thi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: E. Gramsch, P. Oyola, F. Reyes, Y. Vásquez, M. A. Rubio, C. Soto, P. Pérez, F. Moreno, N. Gutiérrez
Formato: article
Lenguaje:EN
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://doaj.org/article/bb84929466704522a7a1232e305d7223
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:bb84929466704522a7a1232e305d7223
record_format dspace
spelling oai:doaj.org-article:bb84929466704522a7a1232e305d72232021-11-12T05:37:24ZInfluence of Particle Composition and Size on the Accuracy of Low Cost PM Sensors: Findings From Field Campaigns2296-665X10.3389/fenvs.2021.751267https://doaj.org/article/bb84929466704522a7a1232e305d72232021-11-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fenvs.2021.751267/fullhttps://doaj.org/toc/2296-665XIn the last decade, many low-cost monitoring sensors and sensor-networks have been used as an alternative air quality assessment method. It is also well known that these low cost monitors have calibration, accuracy and long term variation problems which require various calibration techniques. In this work PM2.5 and PM10 low cost sensors (Plantower and Nova Fitness) have been tested in five cities under different environmental conditions and compared with collocated standard instruments. Simultaneously, particle composition (organic and black carbon, sulfate, nitrate, chloride, ammonium, and chemical elements) has been measured in the same places to study its influence on the accuracy. The results show a very large variability in the correlation between the low cost sensors and collocated standard instruments depending on the composition and size of particles present in the site. The PM10 correlation coefficient (R2) between the low cost sensor and a collocated regulatory instrument varied from to 0.95 in Temuco to 0.04 in Los Caleos. PM2.5 correlation varied from 0.97 to 0.68 in the same places. It was found that sites that had higher proportion of large particles had lower correlation between the low cost sensor and the regulatory instrument. Sites that had higher relative concentration of organic and black carbon had better correlation because these species are mostly below the 1 μm size range. Sites that had higher sulfate, nitrate or SiO2 concentrations in PM2.5 or PM10 had low correlation most likely because these particles have a scattering coefficients that depends on its size or composition, thus they can be classified incorrectly.E. GramschP. OyolaF. ReyesY. VásquezM. A. RubioC. SotoP. PérezF. MorenoN. GutiérrezFrontiers Media S.A.articlelow cost sensorsaccuracyparticle scatteringPM10 and PM2.5particle compositionEnvironmental sciencesGE1-350ENFrontiers in Environmental Science, Vol 9 (2021)
institution DOAJ
collection DOAJ
language EN
topic low cost sensors
accuracy
particle scattering
PM10 and PM2.5
particle composition
Environmental sciences
GE1-350
spellingShingle low cost sensors
accuracy
particle scattering
PM10 and PM2.5
particle composition
Environmental sciences
GE1-350
E. Gramsch
P. Oyola
F. Reyes
Y. Vásquez
M. A. Rubio
C. Soto
P. Pérez
F. Moreno
N. Gutiérrez
Influence of Particle Composition and Size on the Accuracy of Low Cost PM Sensors: Findings From Field Campaigns
description In the last decade, many low-cost monitoring sensors and sensor-networks have been used as an alternative air quality assessment method. It is also well known that these low cost monitors have calibration, accuracy and long term variation problems which require various calibration techniques. In this work PM2.5 and PM10 low cost sensors (Plantower and Nova Fitness) have been tested in five cities under different environmental conditions and compared with collocated standard instruments. Simultaneously, particle composition (organic and black carbon, sulfate, nitrate, chloride, ammonium, and chemical elements) has been measured in the same places to study its influence on the accuracy. The results show a very large variability in the correlation between the low cost sensors and collocated standard instruments depending on the composition and size of particles present in the site. The PM10 correlation coefficient (R2) between the low cost sensor and a collocated regulatory instrument varied from to 0.95 in Temuco to 0.04 in Los Caleos. PM2.5 correlation varied from 0.97 to 0.68 in the same places. It was found that sites that had higher proportion of large particles had lower correlation between the low cost sensor and the regulatory instrument. Sites that had higher relative concentration of organic and black carbon had better correlation because these species are mostly below the 1 μm size range. Sites that had higher sulfate, nitrate or SiO2 concentrations in PM2.5 or PM10 had low correlation most likely because these particles have a scattering coefficients that depends on its size or composition, thus they can be classified incorrectly.
format article
author E. Gramsch
P. Oyola
F. Reyes
Y. Vásquez
M. A. Rubio
C. Soto
P. Pérez
F. Moreno
N. Gutiérrez
author_facet E. Gramsch
P. Oyola
F. Reyes
Y. Vásquez
M. A. Rubio
C. Soto
P. Pérez
F. Moreno
N. Gutiérrez
author_sort E. Gramsch
title Influence of Particle Composition and Size on the Accuracy of Low Cost PM Sensors: Findings From Field Campaigns
title_short Influence of Particle Composition and Size on the Accuracy of Low Cost PM Sensors: Findings From Field Campaigns
title_full Influence of Particle Composition and Size on the Accuracy of Low Cost PM Sensors: Findings From Field Campaigns
title_fullStr Influence of Particle Composition and Size on the Accuracy of Low Cost PM Sensors: Findings From Field Campaigns
title_full_unstemmed Influence of Particle Composition and Size on the Accuracy of Low Cost PM Sensors: Findings From Field Campaigns
title_sort influence of particle composition and size on the accuracy of low cost pm sensors: findings from field campaigns
publisher Frontiers Media S.A.
publishDate 2021
url https://doaj.org/article/bb84929466704522a7a1232e305d7223
work_keys_str_mv AT egramsch influenceofparticlecompositionandsizeontheaccuracyoflowcostpmsensorsfindingsfromfieldcampaigns
AT poyola influenceofparticlecompositionandsizeontheaccuracyoflowcostpmsensorsfindingsfromfieldcampaigns
AT freyes influenceofparticlecompositionandsizeontheaccuracyoflowcostpmsensorsfindingsfromfieldcampaigns
AT yvasquez influenceofparticlecompositionandsizeontheaccuracyoflowcostpmsensorsfindingsfromfieldcampaigns
AT marubio influenceofparticlecompositionandsizeontheaccuracyoflowcostpmsensorsfindingsfromfieldcampaigns
AT csoto influenceofparticlecompositionandsizeontheaccuracyoflowcostpmsensorsfindingsfromfieldcampaigns
AT pperez influenceofparticlecompositionandsizeontheaccuracyoflowcostpmsensorsfindingsfromfieldcampaigns
AT fmoreno influenceofparticlecompositionandsizeontheaccuracyoflowcostpmsensorsfindingsfromfieldcampaigns
AT ngutierrez influenceofparticlecompositionandsizeontheaccuracyoflowcostpmsensorsfindingsfromfieldcampaigns
_version_ 1718431194225311744